Laserfiche WebLink
ZepSolar <br />Engineering Calculations <br />Snow Load Calculations <br />Using icalculation procedure of ASCE 7-10 Chapter 7 <br />Description (Symbol)Interior Edge Corner Unit <br />Flat Roof Snow Load (Pf) 0.0 0.0 0.0 psf <br />Slope Factor (Cs)0.9 0.9 0.9 <br />Roof Snow Load 0.0 0.0 0.0 psf <br />Wind Pressure Calculations <br />Using simplified procedure of ASCE 7-10 Chapter 27 <br />D.escription (Symbol)Interior Edge Corner Unit <br />Net Design Wind Pressure uplift (net3O_up -19.9 -34.7 -51.3 psf <br />Net Design Wind Pressure dow.nforce (ne€30_down 12.5 12.5 12.5 psf <br />Adjustment Factor for Height and Exposure 1.1 1.1 1.1 <br />Category (A) <br />Design Wind Pressure uplift (Wup)-20.9 -36.4 -53.9 psf <br />Design Wind Pressure downforce (WdowJ 16.0 16.0 16.0 psf <br />ASD Load Combinations <br />Using calculation procedure of ASCE 7-10 Section 2.4 <br />Description (Symbol)Interior Edge Corner Unit <br />Dead Load (D)2.6 2.6 2.6 psf <br />Snow Load (S)0.0 O.0 0.0 psf <br />Load' Combination 1(D+0.75*(0.6*Wdown)+0.75,*S)9.6 9;.6 9.6 Psf <br />Load Combination 2 (D+0.6*Wdown)12.0 12.0 12.0 psf <br />Loa;d Combination 3 (D+S)2.4 2.4 2.4 psf <br />Uplift Design Load (0..6*D+0.6*Wup)-11.1 -20.4 -30.9 psf <br />Maximum Absolute Design Load (Pabs)12.0 12.0 12.0 psf <br />Zep Solar, Inc. www.zepsolancom I 3597911 I 2014-03-06 23:01 UTC Page 3 of 4