GENERAL NOTES <br />\Ain n n <br />CONCRETE <br />CITY OF SANTA ANA <br />v_o <br />ncyI <br />1. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS <br />AT THE JOB SITE, AND SHALL BE RESPONSIBLE FOR COORDINATING THE <br />WORK OF ALL TRADES AND CONDITIONS OF ALL WORK AND MATERIALS <br />INCLUDING THOSE FURNISHED BY SUB -CONTRACTORS. ANY DISCREPANCIES <br />SHALL BE CALLED TO THE ATTENTION OF THE STRUCTURAL ENGINEER <br />IMMEDIATELY AND BE RESOLVED BEFORE PROCEEDING WITH THE WORK. <br />2. ALL MATERIALS AND WORKMANSHIP SHALL BE PERFORMED IN ACCORDANCE <br />WITH 2O22 CALIFORNIA BUILDING CODE AS ADOPTED BY THE CITY. <br />3. ALL DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE SHOWN ON PLANS, <br />SECTIONS AND DETAILS. <br />4. NOTES AND DETAILS ON THE DRAWINGS SHALL TAKE PRECEDENCE OVER <br />GENERAL NOTES AND TYPICAL DETAILS. <br />5. WHERE NO DETAILS SHOWN OR NOTED ON THE DRAWINGS, THE DETAILS <br />SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. <br />6. OPENINGS, POCKETS, SLEEVES, ETC., SHALL NOT BE PLACED IN SLABS, <br />BEAMS, WALLS, COLUMNS AND FOOTINGS UNLESS SPECIFICALLY DETAILED <br />ON THE STRUCTURAL DRAWINGS. <br />7. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED <br />FLOORS OR ROOF. LOADS SHALL NOT EXCEED DESIGN LIVE LOADS FOR <br />EACH PARTICULAR LEVEL. PROVIDE ADEQUATE SHORING AND BRACING IF <br />LOAD EXCEED DESIGN LIVE LOAD OR WHERE STRUCTURE HAS NOT ATTAINED <br />DESIGN STRENGTH. <br />8. THIS SET OF DRAWINGS REPRESENT THE FINISHED STRUCTURE, METHOD OF <br />CONSTRUCTION NOT NECESSARY INDICATED, THE CONTRACTOR SHALL <br />PROVIDE ALL MEASURES NECESSARY TO PROJECT THE STRUCTURE, <br />WORKERS AND OTHER PERSONS DURING CONSTRUCTION. SUCH MEASURES <br />SHALL INCLUDE BUT NOT BE LIMITED TO BRACING, SHORING, SCAFFOLDING, <br />ETC. <br />9. DESIGN CODE: 2022 CBC <br />A. ROOF DESIGN LOADS: <br />• ROOF DEAD LOAD = 15.0 PSF <br />• ROOF LIVE LOAD = 20.0 PSF (REDUCIBLE PER CBC 2022) <br />B. WIND DESIGN: <br />• BASIC WIND SPEED = 95.0 MPH <br />• RISK CATEGORY = II <br />• WIND EXPOSURE = C <br />C. SEISMIC DESIGN: <br />• SEISMIC IMPORTANCE FACTOR, 1 = 1.0 <br />• RISK CATEGORY = II <br />• SITE CLASS = D-DEFAULT <br />• Ss = 1.295 <br />• S1 = 0.464 <br />• SDt = NULL <br />• SDs = 1.036 <br />• Fa = 1.2 <br />• BASIC SEISMIC -FORCE -RESISTING SYSTEM: <br />BEARING WALL SYSTEM <br />LIGHT -FRAMED WALLS SHEATHED W/WOOD STRUCTURAL PANELS <br />RATED FOR SHEAR RESIST. <br />• DESIGN BASE SHEAR, V = 0.145W <br />• SEISMIC RESPONSE COEFFICIENT, Cs = 0.145 <br />• RESPONSE MODIFICATION FACTOR, R = 6.5 <br />• ANALYSIS PROCEDURE. <br />ALLOWABLE STRESS LOAD COMBINATION <br />• REDUNDANCY FACTOR, P = 1.3 <br />FOUNDATION <br />1. AS A CALIFORNIA LICENSED ARCHITECT/ENGINEER, I HAVE CLASSIFIED THE <br />UNDISTURBED NATIVE SOILS TO BE TYPE 5 AND I HAVE ASSIGNED A <br />FOUNDATION PRESSURE OF 1500 PSF FOR THE DESIGN OF FOUNDATIONS <br />RELATED TO THIS PROJECT. <br />2. FOOTING BACKFILL AND UTILITY TRENCH BACKFILL SHALL BE PROPERLY COMPACTED. <br />3. THE CONTRACTOR SHALL TAKE ALL NECESSARY MEASURES TO FULLY PROTECT <br />ADJACENT PROPERTIES. <br />4. ALL SITE PREPARATION SUCH AS GRADING AND COMPACTION OF THE FILL SHALL <br />BE PERFORMED UNDER THE SOILS ENGINEER'S SUPERVISION. THE CONTRACTOR <br />SHALL FOLLOW THE SOILS ENGINEER'S RECOMMENDATIONS AS INCLUDED IN THE <br />SOILS REPORT AND ANY ADDITIONAL RECOMMENDATIONS DURING CONSTRUCTION. <br />5. ALL FOOTING EXCAVATIONS SHALL BE INSPECTED AND APPROVED BY THE SOIL <br />ENGINEER PRIOR TO PLACING CONCRETE. <br />6. BACK FILL SHALL NOT BE PLACED UNTIL SUPPORTING FOUNDATIONS, WALLS AND <br />SLAB HAVE ATTAINED SUFFICIENT STRENGTH TO SUPPORT THE APPLIED LATERAL <br />SOIL PRESSURE. <br />7. NO PIPES OR CONDUITS SHALL EXTEND UNDER ISOLATED COLUMN FOOTINGS OR <br />UNDER CONTINUOUS WALL FOOTINGS, GRADE BEAMS, ECT. UNLESS SPECIFICALLY <br />DETAILED ON THESE PLANS. <br />8. FOUNDATION DESIGN SHALL BE 24" MINIMUM BELOW LOWEST ADJACENT FINAL <br />GRADE, AND 12" MINIMUM WIDTH, BEAR ON FIRM NATIVE OR PROPERLY <br />COMPACTED SOILS. <br />9. SUBGADE SHALL BE 2" SAND OVER POLYETHYLENE FILM VAPOR BARRIER. <br />10. SIDE OF FOUNDATION MAY BE POURED AGAINST STABLE EARTH <br />UNLESS SHOWN OR NOTED OTHERWISE. <br />1 1. CONTRACTOR SHALL PROVIDE TEMPORARY AND PERMANENT DEWATERING FOR <br />EITHER SURFACE WATER, GROUND WATER OR SEEPAGE WATER. <br />12. CONTRACTOR SHALL PROTECT ALL UTILITY LINES, ETC. <br />ENCOUNTERED DURING EXCAVATIONS AND BACKFILLING. <br />13. CONTRACTOR SHALL PROVIDE AND INSTALL ALL CRIBBING SHEATHING AND <br />SHORING REQUIRED TO SAFELY RETAIN THE EARTH BANK. <br />14. CONTRACTOR SHALL BRACE OR PROTECT FROM LATERAL LOADS FOR THE PIT <br />AND RETAINING WALLS UNTILL ATTACHING SLABS ARE COMPLETELY IN PLACE AND <br />HAVE ATTAINED FULL STRENGTH. <br />15. No VERTICAL EXCAVATIONS 5'-0" OR MORE IN DEPTH INTO WHICH <br />A PERSON IS REQUIRED TO DESEND SHALL BE PERMITTED. <br />16. SATURATE THE SOIL 18" DEEP BEFORE PLACING THE CONCRETE SLAB. <br />17. HOLD-DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. <br />18. THE STRUCTRUE WILL BE LOCATED ENTIRELY ON UNDISTURBED NATIVE SOIL. IF THE <br />BUILDING INSPECTOR SUSPECTS FILL, EXPANSIVE SOILS OR ANY GEOLOGIC INSTABILITY <br />BASED UPON OBSERVATION OF THE FOUNDATION EXCAVATION, A SOIL OR GEOLOGICAL <br />REPORT, AND RESUBMITTAL OF PLANS TO PLAN CHECK TO VERIFY THAT THE REPORT <br />RECOMMENDATIONS HAVE BEEN INCORPORATED, MAY BE REQUIRED. <br />1. ALL LUMBER SHALL BE GRADE MARKED DOUGLAS FIR LARCH AND SHALL <br />HAVE THE FOLLOWING GRADES, UNLESS NOTED OTHERWISE: <br />JOISTS & RAFTERS GRADE NO. 2 OR BETTER <br />BEAMS & STRINGERS GRADE NO. 1 AND BETTER <br />DOUBLE TOP PLATES GRADE NO. 1 AND BETTER <br />2X4 STUDS CONSTRUCTION GRADE OR BETTER <br />3X4 & 2X6 STUDS GRADE NO. 2 OR BETTER <br />POSTS AND TIMBERS GRADE NO. 1 AND BETTER <br />2. PLYWOOD SHEATHING SHALL BE FULL SIZE SHEET WHERE <br />POSSIBLE WITH 48" X 32" MINIMUM SHEET SIZE AND LAID <br />CONTINUOUSLY OVER TWO OR MORE SPANS WITH FACE GRAIN <br />PERPENDICULAR TO SUPPORTS. <br />A. FLOOR SHEATHING SHALL BE GRADE MARKED "D.F.P.A. <br />EXTERIOR SHEATHING C-D GRADE" 19/32" THICK WITH <br />EXTERIOR GLUE. PANEL I.D. RATING 32/16 OR BETTER. <br />EDGES SHALL HAVE APPROVED TONGUE -AND -GROOVE JOINTS. <br />NAILED WITH 10d DEFORMED SHANK NAILS AT 6" O.C. AT EDGES <br />AND BOUNDARIES, AT 10" O.C. IN FIELD. U.N.O. <br />B. ROOF SHEATHING SHALL BE GRADE MARKED "D.F.P.A. <br />EXTERIOR SHEATHING C-D GRADE" 15/32" THICK WITH <br />EXTERIOR GLUE. PANEL SPAN RATING 24/0 OR BETTER. <br />NAILED WITH 8d COMMON NAILS AT 6" O.C. AT EDGES AND <br />BOUNDARIES, AT 12" O.C. IN FIELD UNLESS NOTED OTHERWISE. <br />3. ALL NAILS SHALL BE COMMON WIRE NAILS UNLESS NOTED OTHERWISE. <br />SEE FRAMING PLANS OR DETAILS FOR NAIL SIZES AND SPACINGS. <br />NAILS THAT NOT DETAILED OR NOTED SHALL BE IN ACCORDANCE <br />WITH CBC FASTENING SCHEDULE. <br />4. ALL JOIST HANGERS AND FRAMING CONNECTORS SHALL BE <br />"SIMPSON" OR APPROVED EQUAL. <br />5. NO STRUCTURAL MEMBER SHALL BE CUT FOR PIPES, ETC. <br />UNLESS SPECIFICALLY NOTED. <br />6. BOLT HOLES SHALL BE SAME DIAMETER AS THAT OF THE BOLTS. <br />PROVIDE WASHERS BETWEEN BOLT HEADS OR NUTS AND WOOD <br />MEMBERS. <br />7. TIGHTEN NUTS ON ALL BOLTS BEFORE CLOSING IN COMPLETION <br />OF. JOB. <br />8. ALL SILL PLATES RESTING ON CONCRETE OR MASONRY THAT ARE <br />LESS THAN 4'-0" ABOVE GRADE SHALL BE PRESSURE TREATED <br />DOUGLAS FIR. <br />9. ALL SILL BOLTS SHALL BE PLACED STARTING 9" FROM THE ENDS <br />OF A BOARD OR FROM A NOTCH AND SPACED AT INTERVALS <br />AS NOTED ON THE PLANS. <br />10. BLOCKING OR BRIDGING SHALL BE PROVIDED AS REQUIRED <br />PER C.B.C. <br />11. PROVIDE DOUBLE JOISTS UNDER ALL PARTITIONS THAT ARE <br />PARALLEL TO JOISTS. USE 2-16d NAILS AT 16" O.C. TO NAIL <br />THE DOUBLE JOISTS TOGETHER. <br />12. TOP PLATES FOR ALL STUD WALLS SHALL BE 2-2X. LAP FOR <br />TOP PLATES SHALL BE 48" LONG MINIMUM NAILED WITH 16d AT 4" <br />AT EACH LAP UNLESS NOTED OTHERWISE. SPLICES IN UPPER AND <br />LOWER PLATES SHALL BE STAGGERED 10'-0" MINIMUM. <br />13. PRE -DRILL FOR NAILING AS REQUIRED WHEN NAIL SPACING <br />RESULTS IN WOOD SPLITTING. PRE -DRILL HOLES SHALL BE <br />SMALLER THAN THE DIAMETER OF THE NAILS. <br />14. ALL WOOD STUD WALLS SHALL HAVE 2X4 STUDS AT 16" O.C. WHEN <br />HEIGHT BETWEEN LATERAL SUPPORTS LESS THAN 10'-0". WHEN <br />HEIGHT BETWEEN LATERAL SUPPORTS BETWEEN 10'-0" AND 16'-0", USE <br />2X6 STUDS AT 16" O.C. <br />15. THE BOLT HOLES SHALL BE 1 /16" (MAX.) OVERSIZED AT THE <br />CONNECTOR OF THE HOLD-DOWN TO THE POST. <br />"INSPECTOR TO VERIFY." <br />16. THE HOLD-DOWN CONNECTORS SHALL BE TIGHTENED JUST PRIOR <br />TO COVERING THE WALL FRAMING. <br />17. APPROVED PLATE WASHERS, IN -LIEU OF CUT WASHERS, SHALL BE <br />PROVIDED FOR ALL PLYWOOD SHEARWALL SILL PLATE ANCHOR BOLTS. <br />18. THE SILL PLATE ANCHOR BOLTS AND HOLD-DOWN CONNECTOR BOLTS <br />AT ALL PLYWOOD SHEARWALL SHALL HAVE THE PLATE WASHERS AS <br />LISTED. <br />19. CUTTING OR NOTCHING OF WOOD STUDS OR PLATES SHALL NOT <br />EXCEED 25% OF THE STUD/PLATE WIDTH WITH THE EXTERIOR AND <br />BEARING WALL AND NOT TO EXCEED 40% OF THE STUD/PLATE WIDTH <br />IN NONBEARING PARTITIONS. BORED HOLES DIAMETER IS LIMITED TO <br />40% OF THE STUD/PLATE WIDTH INANY STUD AND MAY BE 60% IN <br />NONBEARING PARTITIONS OR WHEN THE BORED STUD IS DOUBLED. <br />20. FULL LENGTH STUDS (BALLOON FRAME) SHALL BE USED ON <br />EXTERIOR WALLS WITH VAULTED CEILING. <br />21. ALL ANCHOR BOLTS & HOLDOWNS SHALL BE TIED IN PLACE PRIOR TO <br />FOUNDATION INSPECTION. <br />22. LUMBER AND PLYWOOD WILL BE GRADE STAMPED BY AN APPROVED <br />INSPECTION AGENCY. <br />23. HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE <br />0.229"x3"x3" PLATE WASHER ON THE POST OPPOSITE THE HOLD-DOWN, <br />AND HOLD-DOWNS SHALL BE TIGHTENED TO FINGER TIGHT PLUS <br />ONE-HALF WRENCH TURN JUST PRIOR TO COVERING THE WALL <br />FRAMING. <br />24. SILL PLATES SHALL BE NATURALLY DURABLE OR <br />PRESERVATIVE -TREATED WOOD. FIELD -CUT ENDS, NOTCHES AND <br />DRILLED HOLES OF PRESERVATIVE -TREATED WOOD SHALL BE <br />FIELD -TREATED PER AWPAM4. <br />25. ALL STRUCTURAL LUMBER SHALL COMPLY WITH DOC PS20 OR EQUIVALENT <br />DOUGLAS FIR -LARCH <br />26. ALL WOOD STRUCTURAL PANELS SHALL COMPLY WITH DOC PS 1 OR <br />DOC PS2. <br />1. ALL CONCRETE SHALL BE <br />NORMAL WEIGHT CONFORMING TO THE <br />FOLLOWING: <br />LOCATION <br />28-DAY MIN. <br />MAXIMUM <br />MIX DESIGN <br />COMPRESSIVE <br />AGGREGATE <br />SLUMP <br />STRENGTH <br />SIZE (IN.) <br />(INCHES <br />A. SLAB ON GRADE <br />4500 psi <br />1 <br />4 (5" MAX) <br />B. FOOTINGS & GR BMS. <br />4500 psi <br />1.5 <br />4 5" MAX) <br />NO SPECIAL INSPECTIONS <br />REQUIRED IF <br />CONCRETE TRUCK MIX <br />TICKET PROVIDED. <br />2. ALL CONCRETE MIX DESIGN SHALL HAVE WATER TO CEMENT RATIO <br />W/C=0.45 AND SHALL BE REVIEWED BY THE ENGINEER PRIOR TO <br />CONSTRUCTION. <br />3. PORTLAND CEMENT SHALL CONFORM TO ASTM C-150, TYPE V. <br />4. AGGREGATE SHALL CONFORM TO ASTM C-33. <br />5. WATER SHALL BE CLEAN, FREE FROM DELETERIOUS AMOUNTS OF <br />ACIDS, ALKALIS OR ORGANIC MATERIALS, OILS, SALTS AS PER <br />CBC 2022. <br />6. CONCRETE MIXING OPERATIONS, ETC. SHALL CONFORM TO ASTM C-94. <br />7. UNLESS SHOWN OR NOTED OTHERWISE, CONCRETE COVERAGE FOR <br />REINFORCING BAR TO FACE OF BAR SHALL BE AS FOLLOWS: <br />A. CONCRETE IN CONTACT WITH EARTH, UNFORMED 3" <br />B. CONCRETE IN CONTACT WITH EARTH, FORMED 2" <br />C. WALLS 1.5" <br />D. BEAMS, GIRDERS & COLUMNS (TO TIES OR STIRRUPS) 1.5" <br />8. CONDUIT PLACED IN A CONCRETE SLAB SHALL NOT EXCEED 1/3 <br />OF THE THICKNESS OF THE SLAB AND SHALL BE PLACED BETWEEN <br />THE TOP AND BOTTOM REINFORCING STEEL. MINIMUM CLEAR <br />DISTANCE BETWEEN CONDUITS SHALL BE 6". <br />9. CONCRETE SHALL BE CURED IN ACCORDANCE WITH SECT 1905.11 <br />OF C.B.C. <br />10.REMOVAL OF CONCRETE FORMS AND SHORES SHALL BE IN <br />ACCORDANCE WITH CBC 2022. <br />11.CONDUITS AND PIPES EMBEDDED IN CONCRETE SHALL COMPLY <br />WITH THE PROVISION OF CBC 2022. <br />12.DESIGN AND CONSTRUCTION OF CONCRETE FORMWORK SHALL <br />CONFORM TO ACI 347 "RECOMMENDED PRACTICE FOR CONCRETE <br />FORMWORK". <br />13.CONSTRUCTION JOINTS: <br />THE SURFACES OF ALL CONSTRUCTION JOINTS SHALL BE CLEAN, <br />FREE FROM LOOSE DEBRIS. IMMEDIATELY BEFORE NEW CONCRETE <br />IS PLACED, ALL CONSTRUCTION JOINTS SHALL BE WETTED AND <br />STANDING WATER REMOVED. <br />14.ALL SAW CUTS IN SLAB ON GRADE SHALL BE MADE NOT LATER <br />THAN 24 HOURS AFTER PLACING CONCRETE. <br />REINFORCING STEED <br />1. ALL REINFORCING BARS SHALL BE ASTM A-615 GRADE 60 <br />DEFORMED BILLET STEEL BARS, EXCEPT NOTED BELOW: <br />A. WELDED SMOOTH WIRE FABRIC SHALL CONFORM TO ASTM A-185. <br />2. GRADE 60 BARS SHALL BE MARKED SO ITS IDENTIFICATION CAN BE <br />MADE WHEN THE FINAL IN PLACE INSPECTION IS MADE. <br />3. THE TIE WIRE USED SHALL BE BLACK ANNEALED WIRE, 16 GA. OR <br />HEAVIER. <br />4. BAR SUPPORTS SHALL CONFORM TO THE BAR SUPPORT <br />SPECIFICATIONS CONTAINED IN THE "MANUAL OF STANDARD <br />PRACTICE" BY ACI. <br />5. A CERTIFIED COPY OF MILL TEST ON EACH HEAT OF REINFORCING <br />STEEL DELIVERD SHOWING PHYSICAL AND CHEMICAL ANALYSIS <br />SHALL BE PROVIDED UPON REQUEST AT THE TIME OF SHIPMENT. <br />6. ALL REQUIREMENT OF CONCRETE REINFORCEMENT NOT COVERED ON <br />THE DRAWINGS SHALL BE IN ACCORDANCE WITH ACI "MANUAL OF <br />STANDARD PRACTICE". <br />7. REINFORCING STEEL AT THE TIME OF THE CONCRETE IS PLACED <br />SHALL BE FREE FROM MUD, OIL, OR OTHER NON METALLIC <br />COATINGS THAT ADVERSELY AFFECT BONDING CAPACITY. <br />8. ALL HOOKS SHALL CONFORM TO THE BEND DIMENSION PER ACI <br />"STANDARD HOOK" UNLESS OTHERWISE SHOWN ON THE DRAWINGS. <br />9. REINFORCING BARS SHALL NOT BE BENT OR STRAIGHTENED IN A <br />MANNER THAT WILL INJURE THE MATERIAL. <br />10. REINFORCING BARS SHALL CONFORM ACCURATELY TO THE DIMENSIONS <br />SHOWN ON THE DRAWINGS WITH THE FABRICATING TOLERANCES PER <br />ACI "MANUAL OF STANDARD PRACTICE." <br />11. BARS SHALL BE SECURELY TIED TO PREVENT DISPLACEMENT DURING <br />THE CONCRETING OPERATION AND ALL DOWELS SHALL BE WIRED IN <br />PLACE BEFORE DEPOSITING CONCRETE. <br />12. SPLICES OF REINFORCEMENT SHALL HAVE 42 BAR DIAMETER LAP <br />OR 2'-0" LAP MINIMUM. <br />13. DOWELS BETWEEN FOOTINGS AND WALLS OR COLUMNS SHALL HAVE <br />SAME SIZE AS THE VERTICAL REINFORCEMENT, EMBEDMENT OF <br />DOWELS SHALL BE 36 BAR DIAMETER OR 2'-0" MINIMUM <br />UNLESS OTHERWISE SHOWN. <br />14. MINIMUM LAP OF MESH SHALL BE NOT LESS THAN THE SPACING <br />OF THE CROSS WIRE PLUS TWO INCHES OR 60 DIA. OR 8 IN. <br />WHICHEVER IS GREATER. <br />1-112D CLEAR OR BARS <br />MAY BE IN CONTACT <br />IF WIRED TOGETHER. <br />CONDITION WHERE BARS <br />CLASS B" SPLICE TYP. OCCUR ON SAME PLANE <br />UNLESS NOTED SUCH AS, CONC BE4MS, <br />tM <br />CONC COLUMNS, ETC. <br />RE NF. BENDING DETAIL <br />SPECIAL INSPECTION R EOU I R EM EN TS: <br />1 THIS SECTION APPLIES TO THE STRUCTURAL PORTIONS OF THE PROJECT REQUIRING <br />SPECIAL INSPECTION. THE SPECIAL INSPECTOR'S DUTIES ARE AS DESCRIBED IN CBC 1704, <br />1707 AND CBC 1708. <br />2. ALL TESTS AND INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT TESTING AND <br />INSPECTION AGENCY EMPLOYED BY THE OWNER OR ARCHITECT AND NOT THE CONTRACTOR <br />PER CBC SECTION 1704.1. <br />3. THE SPECIAL INSPECTOR SHALL BE REGISTER WITH THE CITY. <br />4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING THE TEST AND INSPECTION <br />FIRM WITH A SCHEDULE TO FACILITATE THE PROPER COORDINATION OF WORK. <br />5. PORTIONS OF WORK REQUIRING SPECIAL INSPECTION: <br />A. ALL EPDXY ANCHORS <br />B. ALL SHEAR WALLS WITH NAILING LESS OR EQUAL 4" SPACING. <br />PLYWOOD SHEAR WALL PANEL TYPE SCHEDULE <br />SPACING OF 518"0 x <br />ALLOWABLE SHEAR <br />12" LONG ANCHOR. <br />FORCE <br />TYPE <br />CONSTRUCTION <br />BOLTS @ SILL R <br />112" STRUCTURAL 1 PLYWOOD NAILED WITH 8d NAILS © 6" O.C. AT <br />EDGES AND 12" O.C. FIELD AT SIDE ONLY. <br />PLATES BETWEEN FLOOR TO BE NAILED WITH 16d NAILS SPACED <br />48" O.C. <br />210 PLF <br />6" O.C. ALLOWABLE SHEAR FORCE 210 plf. <br />112" STRUCTURAL I PLYWOOD NAILED WITH 8d NAILS ® 4" O.C. AT <br />AEDGES <br />AND 12" O.C. FIELD AT SIDE ONLY. <br />320 PLF <br />PLATES BETWEEN FLOOR TO BE NAILED WITH 16d NAILS SPACED ® <br />32" O.C. <br />4" O.C. ALLOWABLE SHEAR FORCE 320 plf. <br />SEE NOTE* <br />112" STRUCTURAL I PLYWOOD NAILED WITH 8d NAILS © 3" O.C. AT <br />3 <br />EDGES AND 12" O.C. FIELD AT SIDE ONLY. <br />410 PLF <br />PLATES BETWEEN FLOOR TO BE NAILED WITH 112" x 0'-6" LONG <br />24" O.C. <br />LAG BOLTS ® 16" O.C. ALLOWABLE SHEAR FORCE 410 plf. <br />SEE NOTE* <br />112" STRUCTURAL I PLYWOOD NAILED WITH 8d NAILS ® 2" O.C. AT <br />EDGES AND 12" O.C. FIELD AT SIDE ONLY. <br />550 PLF <br />PLATES BETWEEN FLOOR TO BE NAILED WITH 112" x 0'-6" LONG <br />16" O.C. <br />LAG BOLTS Cam? 12" O.C. ALLOWABLE SHEAR FORCE 550 plf. <br />SEE NOTE* <br />NOTE * <br />1. SILL PLATE AND FRAMING MEMBER RECEIVING EDGE NAILING FROM ABUTTING PANELS <br />SHALL NOT BE LESS THAN A SINGLE 3" NOMINAL MEMBER. <br />2. FOR SHEAR PANEL ON BOTH SIDES OF WALL, USE ONE-HALF THE SPACING OF BOLTS. <br />3. PLATE WASHERS (3" x 3" x 114") SHALL BE USED ON EACH 518"0 ANCHOR BOLT. <br />4. SILL PLATES SHALL BE NATURALLY DURABLE OR PRESERVATIVE -TREATED WOOD. <br />FIELD -CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE -TREATED WOOD <br />SHALL BE FIELD -TREATED PER AWPAM4. <br />STRUCTURAL OBSERVATION PROGRAM <br />AND DESIGNATION OF THE <br />STRUCTURAL OBSERVER <br />PROJECT ADDRESS: 2233 W Hall Ave. Santa Ana PERMIT APPL. NO.: <br />Description of Work: Install new Wood Strong Wall High Strenght <br />Owner: <br />Architect: <br />Engineer: Sam Mobed <br />STRUCTURAL OBSERVATION <br />(only checked items are required) <br />Firm or Individual to be responsible for the Structural Observation: <br />Name: Nick Engineering Phone: (310 ) 433-7927 Calif. Registration: C75884 <br />FOUNDATION <br />WALL <br />FRAME <br />DIAPHRAGM <br />�( Footing, Stem Walls, Piers <br />❑ Concrete <br />❑ Steel Moment Frame <br />❑ Concrete <br />❑ Mat Foundation <br />❑ Masonry <br />❑ Steel Braced Frame <br />❑ Steel Deck <br />❑ Caisson, Piles, Grade Beams <br />❑ Wood <br />❑ Concrete Moment Frame <br />❑ Wood <br />❑ Step'g/Retain'g Foundation, Hillside <br />Special Anchors <br />Others: <br />WSWH <br />❑ Others: <br />❑ Others: <br />❑ Others: <br />DECLARATION BY OWNER <br />I, the Owner of the project, declare that the above listed firm or individual is hired by me to be the <br />Structural Observer. <br />Signature Date <br />DECLARATION BY ARCHITECT OR ENGINEER OF RECORD (required if the Structural Observer is <br />different from the Architect or Engineer of Record) <br />I, the Architect or Engineer of record for the project, declare that the above listed firm or individual is <br />designated by me to be responsible for the Structural Observation. <br />Signature License No. Date <br />IN/Form.08(Part 2)(Rev .06119117) <br />I <br />0 <br />taster ID: <br />atINJOK Ef16111EER1 1G <br />Irvine, CA 92614 <br />t: 310.433.7927 <br />e: smobed@nickengineering.com <br />LREV <br />1 10/25/25 PLCC1 <br />DATE DESCRIPTION <br />PROJECT <br />Tea Residence <br />2233 W Hall Ave. <br />Santa Ana, CA 92704 <br />ESS <br />NO. 75884 ' <br />EXP. 06.30.26 <br />IT IS A VIOLATION OF LAW FOR ANY PERSON, <br />UNLESS THEY ARE ACTING UNDER THE DIRECTION <br />OF A LICENSED PROFESSIONAL ENGINEER, <br />TO ALTER THIS DOCUMENT. <br />SHEET TITLE <br />STRUCTURAL NOTES <br />SHEET NUMBER <br />smi <br />E <br />