Laserfiche WebLink
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs) 454 @ 22' 3 1/2" 1406 (1.50") Passed (32%) --1.0 D + 1.0 Lr (All Spans) <br />Shear (lbs) 418 @ 21' 5 1/8" 2531 Passed (17%) 1.25 1.0 D + 1.0 Lr (All Spans) <br />Moment (Ft-lbs) 2506 @ 11' 3" 3411 Passed (73%) 1.25 1.0 D + 1.0 Lr (All Spans) <br />Live Load Defl. (in) 0.588 @ 11' 3" 1.196 Passed (L/488) -- 1.0 D + 1.0 Lr (All Spans) <br />Total Load Defl. (in) 0.907 @ 11' 3" 1.595 Passed (L/317) -- 1.0 D + 1.0 Lr (All Spans) <br />Member Length : 24' 6 1/2" <br />System : Roof <br />Member Type : Joist <br />Building Use : Residential <br />Building Code : IBC 2024 <br />Design Methodology : ASD <br />Member Pitch : 5/12 <br />• Deflection criteria: LL (L/240) and TL (L/180). <br />• Allowed moment does not reflect the adjustment for the beam stability factor. <br />• A 15% increase in the moment capacity has been added to account for repetitive member usage. <br />• Applicable calculations are based on NDS. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger <br />• ¹ See Connector grid below for additional information and/or requirements. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Roof Live Factored Accessories <br />1 - Beveled Plate - DF 3.50" 3.50" 1.50" 162 300 463 Blocking <br />2 - Hanger on 11 1/4" DF beam 3.50" Hanger¹ 1.50" 163 302 466 See note ¹ <br />•Maximum allowable bracing intervals based on applied load. <br />•Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu) 5' 2" o/c <br />Bottom Edge (Lu) 24' 2" o/c <br />Connector: Simpson Strong-Tie <br />Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories <br />2 - Face Mount Hanger LRU212Z 1.94" N/A 6-10dx1.5 7-10d <br />• Refer to manufacturer notes and instructions for proper installation and use of all connectors. <br />Dead Roof Live <br />Vertical Load Location (Side)Spacing (0.90)(1.25)Comments <br />1 - Uniform (PSF) 0 to 22' 7" 16" 10.0 20.0 ROOF <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ <br />document-library. <br />The product application, input design loads, dimensions and support information have been provided by Sam Mobed <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). <br />MEMBER REPORT PASSED <br />ROOF, RR-1 <br />1 piece(s) 2 x 12 DF No.2 @ 16" OC <br />7/14/2024 1:43:44 AM UTC <br />Sam Mobed <br />Nick Engineering Inc. <br />(310) 433-7927 <br />smobed@gmail.com <br />ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2 <br />File Name: 2233 W Hall Ave <br />Page 1 / 1 <br />4