Laserfiche WebLink
A-2 <br />TEA RESIDENCE <br />SHEET <br />REV DATE DESCRIPTION <br />02/22/24A <br />T H E R E S H A L L B E N O C H A N G E S O R D E V I A T I O N O N T H E S E P L A N S W I T H O U T T H E C O N S E N T O F P L A N A N D P E R M I T I N C . N O T E S A N D D E T A I L S O N T H E D R A W I N G S S H A L L T A K E P R E C E D E N C E O V E R G E N E R A L N O T E S A N D T Y P I C A L D E T A I L S . W H E R E N O D E T A I L S S H O W N O R N O T E D O N T H E D R A W I N G S , T H E D E T A I L S S H A L L B E T H E S A M E A S F O R O T H E R S I M I L A R W O R K .C O N T R A C T O R S H A L L V E R I F Y A L L P L A N S , E X I S T I N G D I M E N S I O N S A N D F I E L D C O N D I T I O N S O N T H E J O B S I T E A N D S H A L L I M M E D I A T E L Y N O T I F Y T O P L A N A N D P E R M I T I N C A N Y D I S C R E P A N C I E S I N W R I T I N G P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K O R B E R E S P O N S I B L E F O R S A M E . <br />TH <br />E <br />S <br />E <br /> <br /> <br />D <br />E <br />S <br />I <br />G <br />N <br />S <br />, <br />D <br />R <br />A <br />W <br />I <br />N <br />G <br />S <br /> <br />A <br />N <br />D <br /> <br />S <br />P <br />E <br />C <br />I <br />F <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br />S <br /> <br />A <br />R <br />E <br /> <br />T <br />H <br />E <br /> <br />P <br />R <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />A <br />N <br />D <br /> <br />C <br />O <br />P <br />Y <br />R <br />I <br />G <br />H <br />T <br /> <br />O <br />F <br /> <br />P <br />L <br />A <br />N <br /> <br />A <br />N <br />D <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />I <br />N <br />C <br /> <br />A <br />N <br />D <br /> <br />S <br />H <br />A <br />L <br />L <br /> <br />N <br />O <br />T <br /> <br />B <br />E <br /> <br />U <br />S <br />E <br />D <br /> <br />I <br />N <br /> <br />C <br />O <br />N <br />N <br />E <br />C <br />T <br />I <br />O <br />N <br /> <br />W <br />I <br />T <br />H <br /> <br />A <br />N <br />Y <br /> <br />O <br />T <br />H <br />E <br />R <br /> <br />W <br />O <br />R <br />K <br /> <br />E <br />X <br />C <br />E <br />P <br />T <br /> <br />B <br />Y <br /> <br />A <br />G <br />R <br />E <br />E <br />M <br />E <br />N <br />T <br /> <br />W <br />I <br />T <br />H <br /> <br />P <br />L <br />A <br />N <br /> <br />A <br />N <br />D <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />I <br />N <br />C <br />. <br /> <br />B <br />Y <br /> <br />U <br />S <br />I <br />N <br />G <br /> <br />T <br />H <br />E <br />S <br />E <br /> <br />P <br />L <br />A <br />N <br />S <br />, <br /> <br />T <br />H <br />E <br /> <br />U <br />S <br />E <br />R <br /> <br />A <br />G <br />R <br />E <br />E <br />S <br /> <br />T <br />O <br /> <br />R <br />E <br />L <br />E <br />A <br />S <br />E <br /> <br />P <br />L <br />A <br />N <br /> <br />A <br />N <br />D <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />I <br />N <br />C <br /> <br />F <br />R <br />O <br />M <br /> <br />A <br />N <br />Y <br /> <br />A <br />N <br />D <br /> <br />A <br />L <br />L <br /> <br />C <br />L <br />A <br />I <br />M <br />S <br />, <br /> <br />L <br />I <br />A <br />B <br />I <br />L <br />I <br />T <br />I <br />E <br />S <br />, <br /> <br />S <br />U <br />I <br />T <br />S <br />, <br /> <br />A <br />N <br />D <br /> <br />D <br />E <br />M <br />A <br />N <br />D <br />S <br /> <br />O <br />N <br /> <br />A <br />C <br />C <br />O <br />U <br />N <br />T <br /> <br />O <br />F <br /> <br />A <br />N <br />Y <br /> <br />I <br />N <br />J <br />U <br />R <br />Y <br />, <br /> <br />D <br />A <br />M <br />A <br />G <br />E <br /> <br />O <br />R <br /> <br />L <br />O <br />S <br />S <br /> <br />O <br />R <br /> <br />P <br />E <br />R <br />S <br />O <br />N <br />S <br /> <br />O <br />R <br /> <br />P <br />R <br />O <br />P <br />E <br />R <br />T <br />Y <br />, <br /> <br />I <br />N <br />C <br />L <br />U <br />D <br />I <br />N <br />G <br /> <br />I <br />N <br />J <br />U <br />R <br />Y <br /> <br />O <br />R <br /> <br />D <br />E <br />A <br />T <br />H <br />, <br /> <br />O <br />R <br /> <br />E <br />C <br />O <br />N <br />O <br />M <br />I <br />C <br /> <br />L <br />O <br />S <br />S <br />E <br />S <br />, <br /> <br />A <br />R <br />I <br />S <br />I <br />N <br />G <br /> <br />O <br />U <br />T <br /> <br />O <br />F <br /> <br />T <br />H <br />E <br /> <br />U <br />S <br />E <br /> <br />O <br />F <br /> <br />T <br />H <br />E <br />S <br />E <br /> <br />P <br />L <br />A <br />N <br />S <br />. <br />03/04/24B SKETCH FOR APPROVAL <br />SKETCH FOR REVIEW <br />90PD FOR REVIEWD <br />90PD FOR APPROVAL <br />G 100PD FOR SUBMITTAL <br />E <br />PROPERTY ADDRESS: <br />2233 W HALL AVE, <br />SANTA ANA, CA 92704 <br />PLAN AND PERMIT INC. <br />ARCHITECTURAL DESIGN SERVICES <br />9891 IRVINE CENTER DR #200 <br />IRVINE, CA 92618 <br />(714)-715-0923 <br />biz@planandpermit.com <br />LOCATION QR CODE: <br />STATE OF CAL IFORNIA <br />EXP. DATE <br />L <br />I <br />C <br />E <br />NS E D A R C H <br />I <br />T <br />E <br />C <br />T <br />C - 34643 <br />06/30/2027 <br />SIGNATURE <br />PAUL SAN GEMINO <br />04/18/24 <br />04/24/24 <br />07/24/24 <br />03/18/24C SKETCH FOR APPROVAL <br />PER STRUCTURALF05/23/24 <br />10/29/24 PER PLANNINGH <br />02/11/25PC1 <br />10/05/25 REV11 <br />CITY COMMENTS <br />1 EXISTING ROOF PLAN 2 PROPOSED ROOF PLAN <br />ROOF PLANS <br />04'4'8' <br />1 4" = 1'-0" <br />04'4'8' <br />14" = 1'-0" <br />BUILDING SECTION DESIGNATION <br />SHEET NUMBER <br />BUILDING ELEVATION DESIGNATION <br /> SHEET NUMBER <br />LEGEND: <br />= <br />= <br />= <br />DETAIL REFERENCE <br /> SHEET NUMBER =FLOOR ELEVATION CHANGE <br />WINDOW DESIGNATION <br />DOOR DESIGNATION <br />ROOM <br />CEILING HEIGHT, FLOORING <br />= <br />= <br />== <br />=WALL SECTION REFERENCE <br /> SHEET NUMBER = <br />= <br />= <br />SMOKE ALARM SEALED BATTERY PHOTOELECTRIC <br />SMOKE DETECTOR WITH IONIZATION SENSOR, <br />INTERCONNECTED AND HARD-WIRED,(UL 217). <br />CARBON MONOXIDE ALARM SEALED BATTERY PHOTOELECTRIC, <br />INTERCONNECTED AND HARD-WIRED,(UL 2034). <br />=NEW WALL 2X4==WALL TO STAY <br />WALL TO DEMO= <br />REVISION DESIGNATION= <br />=NEW WALL 2X6= <br />=1HR FIRE RATED WALL 2X4= <br />==1HR FIRE RATED WALL 2X6EXISTING 1HR FIRE RATED COMMON WALL=ROOM <br />0" CLG, FLOORING <br />MAX.7 3 4" <br />5: <br />1 <br />2 <br /> <br />P <br />I <br />T <br />C <br />H <br />5: <br />1 <br />2 <br /> <br />P <br />I <br />T <br />C <br />H <br />(E) OVERHANG TO BE REMOVED.TYP. <br />5: <br />1 <br />2 <br /> <br />P <br />I <br />T <br />C <br />H <br />5: <br />1 <br />2 <br /> <br />P <br />I <br />T <br />C <br />H <br />5:12 PITCH5:12 PITCH <br />(N) ROOF W/ ASPHALT SHINGLE, LANDMARK, <br />CLASS A, COLOR: TO BE MATCHED W/ (E) ROOF, <br />ICC-ES-ESR-1389 & ESR-3537. (OR APPROVED <br />EQUAL) <br />REMOVE (E) ROOFING MATERIAL AND <br />UNDERLAYMENT TO SHEATHING. PREP <br />(E) ROOF FOR (N) ROOF ASSEMBLY. <br />·ROOF VENT CALCULATIONS: <br />1/150TH OF AREA REQUIRED AT ROOF <br />·ATTIC AREA: 445 SF <br />@ DINING ROOM, MASTER BATH & MASTER WIC: <br />445 SF / 150 SF = 3 SF REQUIRED <br />LOWER VENT: 60% X 3 SF = 1.8 SF REQUIRED ---> 3 DORMER VENTS x 0.69 SF = 2.07 SF PROVIDED. <br />UPPER VENT: 40% X 3 SF = 1.2 SF REQUIRED ---> 1 GABLE VENT x 1.25 SF = 1.25 SF PROVIDED. <br />ROOF NOTE: <br />a.A MINIMUM OF 1" AIRSPACE SHALL BE PROVIDED BETWEEN INSULATION AND ROOF SHEATHING. <br />OPENINGS SHALL BE PLACED SO AS TO PROVIDE CROSS VENTILATION OF THE ATTIC SPACE. <br />b.THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE ATTIC AREA. <br />c.VENT OPENINGS SHALL BE COVERED WITH NON-COMBUSTIBLE CORROSION RESISTANT, METAL <br />WIRE MESH OR OTHER MATERIALS HAVING OPENINGS 1/16” MINIMUM TO 1/8” MAXIMUM. <br />d.50% OF THE REQUIRED VENTILATION AREA MUST BE LOCATED AT LEAST 3 FT. ABOVE EAVE OR <br />CORNICE VENTS WITH THE BALANCE PROVIDED BY EAVE OR CORNICE VENTS. <br />e.WHERE THE RATIO OF 1/300 IS USED TO VENT THE ATTICS, NOT LESS THAN 40% BUT NOT MORE <br />THAN 50% OF THE VENTS SHALL BE LOCATED NOT MORE THAN 3 FT. BELOW THE RIDGE. <br />(N) 24 IN. X 12 IN. GALVANIZED STEEL <br />HALF-ROUND DORMER VENT W/ 1 8" SCREEN, <br />GIBRALTAR BUILDING PRODUCTS (OR APPROVED <br />EQUAL). EACH VENT HAS 0.69 SF. N.F.V. SEE ROOF <br />VENT CALCS.