My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2102 S Flower St - DEF - Storefront - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Flower St
>
2102 S Flower St
>
2102 S Flower St - DEF - Storefront - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2026 5:00:11 AM
Creation date
2/5/2026 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
101126259
Full Address
2102 S Flower St
Street Number
2102
Street Direction
S
Street Name
Flower
Street Suffix
St
Text box
ID:
1
Creator:
Import Agent
Created:
2/5/2026 5:00 AM
Modified:
2/4/2026 12:22 PM
Text:
www.hilti.com
ID:
2
Creator:
Import Agent
Created:
2/5/2026 5:00 AM
Modified:
2/4/2026 12:22 PM
ID:
3
Creator:
Import Agent
Created:
2/5/2026 5:00 AM
Modified:
2/4/2026 12:22 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
www.hilti.com <br />Hilti PROFIS Engineering 3.1.16 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />1 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br /> | <br />250606 - SF Concrete - June 16, 2025 <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />1 <br />6/16/2025 <br />Specifier's comments: <br />1 Input data <br /> Anchor type and diameter: KWIK HUS-EZ (KH-EZ) (Carbon Steel) 1/4 (2 1/2) <br /> Item number: 418045 KH-EZ 1/4"x2 5/8" <br /> Specification text: Hilti Æ 1/4 in KWIK HUS-EZ (KH-EZ) (Carbon <br /> Steel) with 2.5 in nominal embedment depth <br /> per ICC-ES ESR-3027 , Hammer drill bit <br /> installation per MPII, <br /> Effective embedment depth: hef,act = 1.920 in., hnom = 2.500 in. <br /> Material: Carbon Steel <br /> Evaluation Service Report: ESR-3027 <br /> Issued I Valid: 12/1/2023 | 12/1/2025 <br /> Proof: Design Method ACI 318-19 / Mech <br /> Shear edge breakout verification: Row closest to edge (Case 3 only from ACI 318-19 Fig. R.17.7.2.1b) <br /> Stand-off installation: <br /> Profile: <br /> Base material: cracked concrete, Custom, fc' = 3,000 psi; h = 6.000 in. <br /> Installation: Hammer drilled hole, Installation condition: Dry <br /> Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present <br /> edge reinforcement: > No. 4 bar <br />17
The URL can be used to link to this page
Your browser does not support the video tag.