Laserfiche WebLink
SIZE CONNECTION AT STEEL FOR SKYLIGHT <br />Details: <br />Design Wind pressure, W =18 psf 1 2 <br />CW5.06 CW5.06 <br />Width (W) =3.91 ft <br />max=59 lbs <br />Check: 1/4"-20 HILTI DRIL-FLEX SELF DRILLING STRUCTURAL FASTENERS [ICC-ESR 3332] <br />n / Ω =526 >59 O.K <br />PROVIDE: <br />SIZE CONNECTION AT STEEL FOR TRELLIS SUNSHADE <br />Details: <br />Design Wind pressure, W =18 psf 1 1 1 <br />CW5.07 CW5.08 CW5.09 <br />Tributary Width (TW) =14.50 ft <br />Attachment Spacing, s =1.50 ft <br />max/n=2=123 lbs <br />Check: 1/4"-20 HILTI DRIL-FLEX SELF DRILLING STRUCTURAL FASTENERS [ICC-ESR 3332] <br />n / Ω =526 >123 O.K <br />PROVIDE: <br />1/4"-20 HWH HILTI KWIK FLEX FASTENERS (1) 4" EA. END AND (1) 16" O.C. IN BETWEEN PER <br />[ICC-ESR 3332] <br />1/4"-20 HWH HILTI KWIK FLEX FASTENERS (2) EA. END AND (3) EVERY OTHER BAY PER [ICC- <br />ESR 3332] <br />51