Laserfiche WebLink
HOANG DAN PHAM, P.E HD ENGINEERING CONSTRUCTION 06/29/2025 <br />1 <br /> <br />2022 CALIFORNIA BUILDING CODE <br />In all cases calculations will supersede this design criteria sheet. <br /> <br />LUMBERS: (NDS 2018, Table 4A), Douglas Fir-Larch #2, with 19% max. moisture content. <br /> <br />4x & Smaller Fb = 900 psi Fv = 180 psi Fc = 625 psi E = 1.6 E6 psi <br /> <br />TIMBERS: (NDS 2018, Table 4D), Douglas Fir-Larch #1 <br /> <br />6x & Larger Fb = 1350 psi Fv = 170 psi Fc = 625 psi E = 1.6 E6 psi <br /> <br />NOTE: It is recommended that all lumbers & timbers shall be free of heart center. <br /> <br /> <br />MANUFACTURED PRODUCTS: <br /> <br />Glu-Lam 24F-V4 Fb = 2400 psi Fv = 240 psi Fc = 650 psi E = 1.8 E6 psi <br />Width: 3-1/8”, 5-1/8”, 6-3/4”, 8-3/4”, and 10-3/4 <br />Depth: 9”, 10-1/2”, 12”, 13-71/2”, 15”, 16-1/2”, 18”, 19-1/2, 21”, 22-1/2”, 24”, 25-1/2”, 27”, <br />28-1/2”, 30”, and 31-1/2” <br /> <br />Microllam LVL Fb = 2600 psi Fv = 285 psi Fc = 750 psi E = 1.9 E6 psi <br />Width: 1-3/4”, 3-1/2”, and 5-1/4” <br />Depth: 9-1/4”, 9-1/2”, 11-1/4”, 11-7/8”, 14”, 16”, 18”, and 20” <br /> <br />Paralam PSL Fb = 2900 psi Fv = 290 psi Fc = 750 psi E = 2.0 E6 psi <br />Width: 1-3/4”, 2-11/16”, 3-1/2”, 5-1/4”, and 7” <br />Depth: 9-1/4”, 9-1/2”, 11-1/4”, 11-7/8”, 14”, 16”, and 18” <br /> <br />NOTE: Values may be adjusted according to IBC Chapter 23. <br /> <br />SILENT FLOOR JOIST: (See TrusJoist Specifier’s Guide) <br /> <br /> Wide Flange Depths Flange Grade <br /> <br />TJI 110 Joists 1-3/4” 9-1/2”, 11-7/8”, 14” E = 1.6 E6 psi <br /> TJI 210 Joists 2-1/16” 9-1/2”, 11-7/8”, 14”, 16” E = 1.6 E6 psi <br /> TJI 230 Joists 2-5/16” 9-1/2”, 11-7/8”, 14”, 16” E = 1.6 E6 psi <br /> TJI 360 Joists 2-5/16” 11-7/8”, 14”, 16” E = 1.6 E6 psi <br /> TJI 560 Joists 3-1/2” 11-7/8”, 14”, 16” E = 1.6 E6 psi <br /> <br />GENERAL: <br />1. All construction shall conform to the California Building Code. <br />2. It is the contractors responsibility to ascertain that construction conform to the structural <br />calculations. Contractor shall field verify all dimensions prior to construction. Any field condition <br />found to be unusual, or not addressed, shall be reported to Design Engineer. <br />3. Any specified shear wall sheathing shall extend continuously from the top to the bottom plates. <br />4. All posts and columns shall be erected with ICC approved (Simpson, or equal) column caps and post <br />bases, or as specified. <br />5. Use standard approved (Simpson, or equal) HU Joist hangers. Unless Otherwise Noted. <br /> <br /> <br /> <br />