My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2064 & 2066 S Van Ness Ave - Plan
PBA
>
Building
>
ProjectDox
>
V
>
Van Ness Ave
>
2066 S Van Ness Ave
>
2064 & 2066 S Van Ness Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2026 5:00:11 AM
Creation date
2/6/2026 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
101125325
Full Address
2066 S Van Ness Ave
Street Number
2066
Street Direction
S
Street Name
Van Ness
Street Suffix
Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)274 @ 13' 11 1/2"1406 (1.50")Passed (20%)--1.0 D + 1.0 Lr (Alt Spans) <br />Shear (lbs)257 @ 13' 6 9/16"1238 Passed (21%)1.25 1.0 D + 1.0 Lr (Alt Spans) <br />Moment (Ft-lbs)874 @ 7' 7 1/16"1060 Passed (82%)1.25 1.0 D + 1.0 Lr (Alt Spans) <br />Live Load Defl. (in)0.602 @ 7' 6 3/4"0.716 Passed (L/286)--1.0 D + 1.0 Lr (Alt Spans) <br />Total Load Defl. (in)0.968 @ 7' 6 3/4"0.955 Passed (L/178)--1.0 D + 1.0 Lr (Alt Spans) <br />Member Length : 15' 10" <br />System : Roof <br />Member Type : Joist <br />Building Use : Residential <br />Building Code : IBC 2021 <br />Design Methodology : ASD <br />Member Pitch : 6/12 <br />•Deflection criteria: LL (L/240) and TL (L/180). <br />•Overhang deflection criteria: LL (2L/240) and TL (2L/180). <br />•Upward deflection on left cantilever exceeds overhang deflection criteria. <br />•Allowed moment does not reflect the adjustment for the beam stability factor. <br />•A 15% increase in the moment capacity has been added to account for repetitive member usage. <br />•Applicable calculations are based on NDS. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger <br />• ¹ See Connector grid below for additional information and/or requirements. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Roof Live Factored Accessories <br />1 - Beveled Plate - DF 3.50"3.50"1.50"125 203 327 Blocking <br />2 - Hanger on 5 1/2" DF beam 3.50"Hanger¹1.50"108 178 286 See note ¹ <br />•Maximum allowable bracing intervals based on applied load. <br />•Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)7' 6" o/c <br />Bottom Edge (Lu)15' 7" o/c <br />Connector: Simpson Strong-Tie <br />Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories <br />2 - Face Mount Hanger LRU26Z 1.94"N/A 4-10dx1.5 5-10d <br />•Refer to manufacturer notes and instructions for proper installation and use of all connectors. <br />Dead Roof Live <br />Vertical Load Location (Side)Spacing (0.90)(1.25)Comments <br />1 - Uniform (PSF)0 to 14' 3"16"11.0 20.0 Roof Load <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ <br />document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). <br />MEMBER REPORT PASSED <br /> Roof, Roof Joist RJ-1 <br />1 piece(s) 2 x 6 DF No.2 @ 16" OC <br />ForteWEB Software Operator Job Notes 6/30/2025 6:35:08 AM UTC <br />Hoang Pham <br />HD Engineering Construction Inc. <br />(714) 495-0056 <br />hdanpham@gmail.com <br />ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 <br />File Name: 2066 South Van Ness Ave, Santa Ana, CA <br />Page 3 / 8