My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10181241_2210 N. SPINNAKER - Plan (2)
PBA
>
Building
>
Plans
>
S
>
Spinnaker St
>
2210 N Spinnaker St
>
10181241_2210 N. SPINNAKER - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2021 11:54:08 PM
Creation date
10/25/2020 9:52:26 PM
Metadata
Fields
Template:
Plan
Permit Number
10181241
Full Address
2210 N Spinnaker St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
,Installation-Mainual: MEMC S.Uvantis..60 cell PV Modules _ _ _5 of 15 <br />4.0 MECHANICAL INSTALLATION <br />4.1 PLANNING AND DESIGN <br />Before installation, check to ensureall sub-structure will accommodate expectedsystem loads. This includes and is not <br />limited to roof, foondations, mechanical structure, and mechanical connections. <br />For roof installations, utilize·a fire-resistant roof covering rated for the application. <br />Mechanical structures should notcontact the module backsheet under any expected load conditions <br />Considerthe followihg factorsduring system design, which will in fluence performance <br />a) MEMC solar modules produce the most power when they are pointed directly at the sun, and should be tilted for <br />optimum system perfotmance. <br />b) Proximity to obstructions such':as: walls, buildings, trees, groundcover,isnow cover, or dust and debris that have the <br />potential to shadeordamage the modules. <br />c) Elevated temperatures will decreaseenergy yield, so designs should ensureadequate airflow across the back of the <br />module. <br />d) Allow a minimum spacing of 10 mm between modules for thermal expansion. <br />4.2 MODULE INSTALLATION OPTIONS FOR MOUNTING LOCATIONS <br />For mounting locations forclamps or bolt forspecified load, please referto Table on page 6. <br />Each module should be mounted using four bolts through:the mounting holes on the rear side of the module, orwith four <br />clamps over the front side. <br />Depending on thedesired load capability of the array, modules may be mounted either perpendicularor parallel to the <br />structure rails. Clamps can be mounted anywhere insideof the safe mounting range foreach case illustrated below (referring <br />to chart showing clamp and bolt mounting locations). <br />I f using boltq, eight mounting holes arp provided on the rparqirle the·morltile fra me ac Ghown i n_Appendix 8.1. l Jse a stai nleqa <br />steel bolt sta¢k no smallerthan 14"-20 or M6, with two flat washers amd ailocking washeras shown in Appendix 8.2. <br />To ensure an adequate clamping area, all clamps used should comply with the following general conditions: <br />1. Clamp height mustcorrespond to 50 mm frame height <br />2. Clamp must have a minimum width of 38 mm <br />3. Clamp depth must be between 6 mm to 10 mm <br />All fasteners used to fixthe modules with clamps should b'e stainless steel, and no smaller than W'-20 or,M6. <br />To provideadequate fixing orclamping forte, torque the ininimum recommended fastenersto 13.6-16.3 N.m [10- 12 ft lb]. <br />All other structural dimensions, such as clamp and rail thickness, should besized appropriately for the intended site load. <br />© Copyright 2012 MEMC Electronic Material <br />-
The URL can be used to link to this page
Your browser does not support the video tag.