Laserfiche WebLink
21 ' SIGN COMPONENTS MANUAL (SAM)January 4, 2010 <br />Class 2 LEDs, Cat. No. "SideWinder Series" may be followed by (Standard) or "SideWinder BL" may be followed by (Back Lit) <br />or'7hinRayz Xtra" may be followed by (High Output) or "ThinRayz" - Cat Nos. AGI-SW1 Y XXX where Y and XXX can be <br />any alphanumeric characters from 0 to 9 incl. and from A to Z ind.; "BrightStrip Series" - AGI-BS-6-X YYY where X and YYY <br />can be any alphanumeric characters from 0 to 9 incl. and from A to Z incl. <br />1. These products are only suitable for connection to a UL Listed or Recognized maximum Class 2, 15 VAC, 30 V DC power <br />source. <br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 <br />circuit limits. <br />3. These Class 2 LED modules, are each rated max. 40 Watts per unit, LED module when units are connected to a Class 2 <br />circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. <br />4. These products are suitable for use in dry, damp or wet locations. <br />5. These products are not required to be enclosed or protected from the weather. <br />LED array drivers, Models AGI-LP1060-12-GG-240 <br />1. These power supplies have a single output that complies with Class 2 output requirements. <br />2. These products are suitable for use in dry, damp and wet locations only. <br />3. The primary sides of these power supplies are suitable for connection with threaded type conduit only. <br />4. Power supply spacing to other heat producing components shall be minimum 4 inches when minimum spacing to sidewalls <br />and top of enclosure is kept at minimum 2 inches. <br />5. When not marked for indoor use only the power supply primary bracket shall be provided with min. 3.5 threads and tapered <br />for connection to liquid tight conduit fitting. <br />6. When not marked for indoor use only, all models shall have liquid tight fittings on both primary and secondary circuits. <br />ALCAN COMPOSITES USA INC.101623 <br />208 W 5TH ST <br />PO BOX 507 <br />BENTON, KY 42025 <br />Strudhq·al Panel, designated "ALUCOBOND" made 3 mm, 4 mm or 6 mm of polyethylene laminated on two sides with <br />aluminurK <br />1. This pAduct is intended as an outer decorative covering, has not been investigated for use as an electrical enclosure. <br />2. The use b(this product is limited to only decorative and sign body applications. <br />3. Thesuitabilik ofthe"lit"of theface material and the "secureness" of the clamp mechanisms on the sign, will be judged inthe end use sign application. <br />4. This product is acceptable for use in dry, damp and wet locations <br />5. The water exclusibn must be determined in the end product. <br />6. This product suitabl<or use in terminating conduit. <br />7. All components other thln neon standoffs or small decorative parts must be secured to the panel by bolts, nuts andwashers of minimum 7/16-in diameter. <br />8. All exposed edges of a strhctural panel, including grilled holes, etc., are be treated with two coats of outdoor paint or wood <br />coating. . , . <br />9. A letter made from a structural pqne I shall have at least two points of support and shall have no point more than 10 in froma point of support. <br />10. These panels shall be attached wittiscrews, bolts or rivets to the structural framework so as to cause bonding to bothconductive surfaces to ground, and to ad&14ptely secure each panel in place. <br />11. ALUCOBOND" panels provided with letter,cutouts, in which 1/8 in. thick thermoformed acrylic shaped letters are pushed <br />through the panel cutout, have an additional 1/8©. flange around the periphery to prevent the acrylic face from falling out of <br />the sign enclosure. These acrylic letters are mechanically attached to the backside of the "ALUCOBOND" on 1/4-20threaded studs. The studs are swaged or welded to*a 2 by 2, No. 16 gauge perforated galvanized steel plate. The studassembly is, in turn, secured with bolts, screws, rivet20< welding, to the "ALUCOBOND" panels. <br />Structural Panel, designated "DIBOND" made 2 mm, 3 m, or 4 mm of polyethylene laminated on two sides with aluminum.1. This product is intended as an outer decorative covering, has not been investigated for use as an electrical enclosure. <br />2. The use of this product is limited to only decorative and si® body applications. <br />3. The suitability of the "fit" of the face material and the "securemess" of the clamp mechanisms on the sign, will be judged in <br />the end use sign application.4. This product is acceptable for use in dry, damp and wet locationk\ <br />5. The water exclusion must be determined in the end product. \ <br />6. This product suitable for use in terminating conduit. <br />7. All components other than neon standoffs or small decorative parts musfbe secured to the panel by bolts, nuts and <br />washers of minimum 7/16-in diameter.8. All exposed edges of a structural panel, including drilled holes, etc., are bed with two coats of outdoor paint or woodcoating.9. A letter made from a structural panel shall have at least two points of support andVil have no point more than 10 in froma point of support <br />10. These panels shall be attached with screws, bolts or rivets to the structural framework s<as to cause bonding to both <br />conductive surfaces to ground, and to adequately secure each panel in place. <br />Structural Panel, designated Sintra Material. <br />1. This product is intended as an outer decorative covering, has not been investigated for use a an electrical enclosure.2. The use of this product is limited to only decorative and sign body applications. \ <br />3. The suitability of the "fi t" of the face material and the "secureness" of the clamp mechanisms on tign, will be judged inthe end use sign application. <br />4. This product is acceptable for use in dry, damp and wet locations <br />5. The water exclusion must be determined in the end product. <br />6. This product suitable for use in terminating conduit.