Laserfiche WebLink
DC DISCONNECT WARNING AC DISCONNECT WARNING SERVICE PANEL <br />PHOTOVOLTAIC SYSTEM <br />DC DISCONNECT <br />OPERATING VOLTAGE XXX VDC <br />OPERATING CURRENT XXX ADC <br />MAX SYSTEM VOLTAGE XXX VDC <br />SHORT CIRCUIT CURRENT XXX ADC <br />A WARNING A <br />ELECTRIC SHOCK HAZARD <br />THE DC CONDUCTORS OF <br />THIS PHOTOVOLTAIC SYSTEM <br />ARE UNGROUNDED AND <br />MAY BE ENERGIZED <br />PERNEC 690.14(C)(2. 8103*F). 69063 0*000 <br />per NEC 690.53 <br />operating voltage, operating current, max system voltage, <br />short circuit current and maximum output current of <br />the charge controller if one is installed. <br />PLACE ON: Main Solar Disconnect <br />PHOTOVOLTAIC SYSTEM <br />- ./.5.m <br />DISCONNECT - <br />PHOTOVOLTAIC SYSTEM <br />AC DISCONNECT <br />OPERATING CURRENT XXX AMPS <br />OPERATING VOLTAGE 240 VOLTS <br />A WARNING A <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH TERMINALS <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />PER NEC 690.141/12). 8917(4). 8954 <br />O..1 <br />per NEC 690.54 <br />operating voltage, operating current <br />PLACE ON: Inverter Breaker Panel <br />if sum of breakers exceeds panels rating <br />CAUTION <br />POWER TO THIS BUILDING IS SUPPLIED FROM <br />THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN <br />m1 <br />1/1 %I <br />MI <br />SOLAR ARRAY E <br />1 <br />r MAIN SERVICE <br />PANEL <br />--1 AC DISCONNECT | <br />INVERTER I <br />PV METER <br />1 <br />1 <br />1 <br />04-b .In 04 650 <br />must show drawing of the property and <br />equipment layout. per NEC 690.56 <br />Sample House <br />1 WARNING A <br />DUAL POWER SUPPLY <br />SOURCES: UTILITY GRID AND <br />PV SOLAR ELECTRIC SYSTEM <br />p.11,bc=n 0121, <br />"Dual Power Supply" label <br />NEC 690.64,705.12(4) <br />Point of Connection <br />1 WARNING A <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH TERMINALS <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />m-=03-100 <br />"Do not touch terminals" label <br />NEC 690.17(4) <br />Switch or Circuit Breakers <br />LABELING <br />Description Date Rev.L S' <br />ORIGINAL 4/25/14 A COR <br />ARB <br />& N <br />ttion@ <br />Ul to! <br />W,ltll <br />Ice . <br />CONTRACTOR: <br />Stearns Solar <br />16381 Nosoni Rd.. - <br />Apple Valley, CA 92307 <br />760-514-1537 Aim <br />LlC# 988327 <br />"PV System Disconnect" label 1 WARNING A HOME OWNER: <br />NEC 690.14(C)(2)Paul Ziesmer <br />Required Disconnect Markings INVERTER OUTPUT CONNECTION CAUTION: SOLAR ELECTRIC THIS ELECTRIC SYSTEM 2202 Freeman St. <br />DO NOT RELOCATE ,IS ALSO SERVED BY A Santa Ana, CA 92706 <br />THIS OVERCURRECT DEVICE SYSTEM CONNECTED -1 PHOTOVOLTAIC SYSTEM i 714-560-0600DC LABELS .....m 01212 - <br />- "Inverter output connection" label i ./.1./.' <br />NEC 705.12(7)PROJECTADDRESS: <br />PLACE ON: 1. DC Junction Boxes Point of Connection 2202 Freeman St. <br />2. DC Combiner Boxes <br />Santa Ana, CA 92706 <br />1 WARNING A OTHER <br />ELECTRIC SHOCK HAZARD <br />THE DC CONDUCTORS OF THIS <br />PHOTOVOLTAIC SYSTEM ARE <br />UNGROUNDED AND <br />MAY BE ENERGIZED <br />P•Utal:cor 01,04 <br />"Electric Shock Hazard" label. NEC 690.35(F) <br />Ungrounded PV Systems <br />PLACE ON: 1. DC Junction Boxes <br />2. DC Combiner Boxes <br />PLACE ON: All DC Source Markings and System <br />Output Conductors Raceways <br />CAUTION SOLAR CIRCUIT <br />pvhbob. com 03-329 <br />"Caution Solar Circuit" label NEC 690.4(F), 690.31(E)(4) <br />place on conduit every 10 feet IFC 605.11.1.1 & IFC 605.11.1.2 <br />'MUST BE REFLECTIVE IF INDOORS OR IN ATTIC <br />PLACE ON: Next to Inverter Interconnection <br />Breaker, Load Center, & Service Panel <br />PV SOLAR BREAKER <br />DO NOT RELOCATE <br />THIS OVERCURRENT <br />_ DEVICE <br />PLACE ON: Near GFI Reset <br />A WARNING A <br />ELECTRIC SHOCK HAZARD <br />IF GROUND FAULT IS INDICATED <br />ALL NORMALLY GROUNDED <br />CONDUCTORS MAY BE <br />UNGROUNDED AND ENERGIZED <br />PHOTOVOLTAIC <br />& POWER j <br />SOURCE <br />10, <br />"Ground Fault Indicated" label <br />NEC 690.5(C) <br />Ground Fault Protection <br />"PV Power Source" label. NEC 690.31(E)(3) <br />DC - PV Source Conductors <br />SIGNAGE REQUIREMENTS:PV-4S <br />RED BACKGROUND. WHITE LETTERING. C'WARNING" - 3/8' LETTERS). ALL CAPITAL LETTERS. ARIAL OR SIMILAR FONT. WEATHER- RESISTANT MATERIAL, UL 969.STRING INVERTER