9.07kW DC ROOF MOUNTED PHOTOVOLTAIC ARRAY FOR THE DOAN RESIDENCE <br />General Notes Sheetlndex <br />ACCE <br />SEAN <br />E FLECTRKN <br />1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE LATEST CALIFORNIA CODE OF REGULATIONS (CCR), NATIONAL <br />ELECTRICAL CODE EDITION AND ALL APPLICABLE LOCAL CODES AND REGULATIONS. (Construction shall comply with 2013 CBC, CMC, CPC, <br />CEC) <br />2. ALL PANELS, SWITCHES, ETC. SHALL HAVE SUFFICIENT GUTTER SPACE AND LUGS IN COMPLIANCE TO UL REQUIREMENTS TO <br />ACCOMMODATE CONDUCTORS SHOWN <br />3. WHERE WIRE SIZES ARE INDICATED ON PLANS FOR INDIVIDUAL CIRCUITS, THE WIRE SIZE INDICATED SHALL APPLY TO THE <br />COMPLETE CIRCUIT, UNLESS OTHERWISE NOTED. <br />4. CONTRACTOR SHALL EXTEND WIRING FROM ALL JUNCTION BOXES, SWITCHES, ETC. AND MAKE FINAL CONNECTIONS AS REQUIRED <br />TO ALL BUILDING EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS. <br />5. DRAWINGS AND DIAGRAMMIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED. FOLLOW DRAWING AND <br />LAYOUT WORK AND CHECK DRAWINGS OR OTHER TRADES RELATING TO WORK TO VERIFY SPACE IN WHICH WORK WILL BE <br />INSTALLED. MAINTAIN HEADROOM AND MINIMUM CODE REQUIRED WORKING CLEARANCES AT ALL TIMES. <br />6. ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT INCLUDING THOSE THAT ARE EXPOSED TO OUTSIDE ENVIRONMENT SHALL <br />BE WEATHERPROOF TYPE NEMA 3R <br />7. DISCONNECT SWITCHES SHALL BE MOUNTED ON INDIVIDUAL SUPPORTS, OR OTHERWISE DIRECTLY ON EQUIPMENT, PROVIDED NO <br />MODIFICATION TO EQUIPMENT IS NECESSARY. <br />PV1 Cover Sheet >5 2 <br />PV2 Details e 2 13 0118 66¢641' <br />PV3 Roof Layout / Plan View k 05 0 5 .1.t Oil; tkfie j <br />PV4 Single Line Diagram .Z :Em=.ttefall*1 60 <br />?4461 54*8PV5Typical Signage E -r 86 J <br />SOMN <br />Cut Sheets + --0/02™:g :%*Wript*D•-22; <br />Spec Sheet - (37) Sunpower SPR-245NE-WHT-D Modules .4. 4 -Oun 1) It@1* B p <br />Spec Sheet - (1) Power-One PVI-4.2-OUT[)-S-US-A Inverter j t,4 r:r®(@WI(21 <br />(1) Power-One PVI-3.8-OUT[>-S-US-A Inverter <br />Engineering Report <br />Design Criteria Planning Criteria <br />BUILDING CODE DATA APN #:412-521-42 <br />' (E)Occupancy Group R-3 No. of Floors: . <br />2 C <br />(E) Type of Construction V-B OR 1§00. <br />, (E)Sprinklers NO . RE <br />PANEL UPGRADE NEEDED? NO <br />-- -,7 <br />A <br />8. ALL ELECTRICAL MATERIAL SHALL BE LISTED BY "UL" FOR THE TYPE OF APPLICATION AND "UL" LABEL SHALL APPEAR ON ALL <br />ELECTRICAL EQUIPMENT. <br />9. WIRING METHOD SHALL BE EMT ABOVE GROUND MOUNTED IN CONCEALED SPACES (UNLESS APPROVED OTHERWISE) AND <br />SCHEDULE- 40 PVC FOR BELOW GROUND INSTALLATION UNLESS NOTED OTHERWISE. <br />10. AN OSHA APPROVED LADDER PROVIDING ACCESS TO ALL PORTIONS OF THE ARRAY SHALL BE SECURED IN PRIOR TO <br />REQUESTING INSPECTION. <br />11..SMOKE ALARMS'AND-EARBON MONOXIDE DETECTORS WILL MEET THE NECESSABYREQUIREMENTS PER CRC R314,11315 <br />- <br />12. UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM. <br />13. ALL EXTERIOR CONDUIT PAINTED TO MATCH EXTERIOR SURFACE. (IF APPLICABLE) <br />14. NO PLUMBING, MECHANICAL OR BUILDING VENTS TO BE COVERED OR OFFSET AROUND ARRAYS. rp <br />I· V E1 ,.S-<C <br />60' "-- <br />--1 -.1 ./.4 <br />CD 0 <br />Existing Single ..m- O CO <br />Family Residence . .Z 15 <br />1 1 <br />0 <br />0 <br />O 1 <br />, -Solar Array <br />bolar I ITRAC1 <br />Date <br />a U=.... '8 ·. el . I. W O) O0- . .-1 <br />- 9 1 <br />E <br />F I 4 6. c z.: ' - - - + .fi f--4'- %94*I*AwM -i¢,744 - . t'-4-r 'B •sy•dda,4.1381iLL!,Adtili-,-f 3 <br />=P ® 0 0tri......,pAlts,72:= 101 : .$-a LA 24143*•0 0 0 -427 '* L• wALM (43- 04,1--®bib©flill midi ,Main Service Panel <br />L 1 4.-.Eli 4 7.16 i..%111 t,1 L :.056*-14*"Ete-;LANNING INSPECTION REQUIRED: <br />AC Disconnect <br />Sunrun Meter Lu <br />11 FINAL-NONE \A Subpanel Of 2 <br />-- Inverters Z cx N <br />0 & LL « <br />1- CO O CD <br />F '211'.-1 - 6.h - 1.L-Ir...., c.„=,-,-IL.#':43:m:=*-¥/M-;3901:d.*-0-p*G' / > **·FAOR -A a) <br />7·*j.3 ---.-- |1 LU <br />| | ECK# <br />rb 5 1-·' :' 'i,kt'[2111:. ,$5- nig;KI3: ,1, 1,£9/ A, f Driveway a. E*< <br />E 49.21-1,39'#51*,61/'Ut#4...18:*-Z <br />--*r, 4->01 f -KA'te. 74 /77 724779 1r-Ji #.4:| rlt.-2-.,0...< 15+-12£ - -- . -. 26i .1 1 60'r- U) <br />UD C <br />. &.rd 1"tlt,1 4-*p':-tht· 4*v Fl·4 *746*Et: * ., .. 1.. ..1 ..0 ...i-:·:·.IL -/ 3-: 1-4.5.U <br />L t. 4%...: <br />W Red Fox Rdr <br />14*PiC 2a 0* 7 44 ·971: 11 3.Project Doan400. 0 -2,52,·v o <br />U Sheet <br />Date 05/21/2014 <br />0 <br />0 <br />Revision/1 <br />i: is <br />0 <br />6c <br />Vicinity Map <br />Scale = NTS <br /> CONDITIONS:3)«ei Site Plan Scale As Noted PV1 i i <br />Plan North Scale: NTS T DrawnPlan North By JR / DA --- <br />A