0N <br />PHOTOVOLTAIC REQUIREMENTS <br />PER CALIFORNIA ELECTRICAL CODE ARTICLE 690 <br />ST <br />PV SYSTEM AC DISCONNECT <br />RATED AC OUTPUT CURRENT - AMPS <br />AC NORMAL OPERATING VOLTAGE 240 VOLTS <br />MAIN SERVICE <br />WARNING <br />DO NOT TOUCH TERMINALS ON BOTH <br />LINE AND LOAD SIDES MAY BE <br />ENERGIZED IN THE OPEN POSITION <br />CEC 690.35 (F) <br />WARNING <br />ELECTRIC SHOCK HAZARD. <br />THE DC CONDUCTORS OF THIS <br />PHOTOVOLTAIC SYSTEM ARE <br />UNGROUNDED AND MAY BE <br />ENERGIZED. <br />WARNING <br />r DO NOT TOUCH TERMINALS ON BOTH <br />LINE AND LOAD SIDES MAY BE <br /> ENERGIZED IN THE OPEN POSITION <br />r EPoe0- LU <br />Address: <br />0 <br />AC <br />ANVAA <br />Marking shall be placed on interior and 2_ <br />0< C <br />exterior DC conduit, raceways, enclosures 28 . - <br />and cable assemblies every 10 ft (3048 mm),56 ...===, <br />within 1 ft (305 mm) of turns or bends and 8%*28 .0 S <br />Z >' .lt.-within 1 foot (305 mm) above and below w @ 5 0.23 0 2 0 C CAOpenetrations of roof/ceiling assemblies, walls <br />or barriers.i=OL_tu,F» <br />0->E W I 0 Sr,\ <br />2*o E* I 0 <br />CAUTION: SOLAR CIRCUIT Z J52 o F CO d <br />E <br />(D <br />LSERVICE j (METER \, COMBINER / <br />INVERTER C 3g- - i METER-j SOCKET DISCONNECT 11 JUNCTION <br />Nlapplicab*1.,ON 1_1 C 3 <br />OFF DC <br />1 <br />ARRAY - <br />0 <br />UN <br />BOX <br />WARNING =DUAL POWER SOURCES SECOND SOURCE IS <br />PHOTOVOLTAIC SYSTEM DC DISCONNECT <br />RATED AC OUTPUT CURRENT 36 AMPS <br />AC NORMAL OPERATING VOLTAGE 240 VOLTS <br />DISCONNECT j I <br />(if applicable) .1 WARNING <br />DO NOT TOUCH TERMINALS ON BOTH <br />LINE AND LOAD SIDES MAY BE <br />1--- --- oFF ENERGIZED IN THE OPEN POSITION <br />36" to 75" above the floor or grade <br />level to center of performance meters <br />(IF APPLICABLE) <br />WARNING: <br />PHOTOVOLTAIC POWER SOURCE <br />WARNING <br />INVERTER OUTPUT CONNECTION. DO NOT <br />RELOCATE THIS OVERCURRENT DEVICE <br />This label is to be located adjacent to the PV breaker <br />1 NOTE: If the Photovoltaic Disconnect is remote and not within <br />sight from the Main Service Disconned, then a directory <br />showing the locations of the Main Service Disconnect and the <br />Photovoltaic Disconnect must be installed at the Main Service Panel <br />location. (SEE SAMPLE DIRECTORY IF APPLICABLE) <br />PV SYSTEM DC DISCONNECT <br />RATED MAX POWER POINT CURRENT - 6.05 AMPS <br />RATED MAX POWER POINT VOLTAGE - 445.5 VOLTS <br />MAXIMUM SYSTEM VOLTAGE - 555.92 VOLTS <br />SHORT CIRCUIT CURRENT - 10.03 AMPS <br />INVERTER 1 <br />PV SYSTEM DC DISCONNECT <br />RATED MIN< POWER POINT CURRENT - 6.05 AMPS <br />RATED MAX POWER POINT VOLTAGE - 445.5 VOLTS <br />MAXIMUM SYSTEM VOLTAGE - 555.92 VOLTS <br />SHORT CIRCUIT CURRENT - 10.03 AMPS <br />INVERTER 2 <br />Recommended signage or labeling specifications <br />A, Red background with white lettering <br />B. 3/8" letter height <br />C. All capital letters <br />D. Arial or similar font <br />E. Weather resistant material (i.e engraved plastic) <br />F. Reflective <br />WARNING <br />ELECTRIC SHOCK HAZARD. <br />IF GROUND FAULT IS INDICATED <br />NORMALLY GROUNDED <br />CONDUCTORS MAY BE UNGROUNDED <br />AND ENERGIZED. <br />Project Doan <br />Sheet <br />Date 05/21/2014 <br />Scale As Noted PV5 <br />Drawn <br />By JR/DA