Laserfiche WebLink
Ir. <br />imm <br />IRRIGATION DETAILS NTS <br />30-INCH LNEAR LENGTH <br />OF WiRE, 1208.E0 <br />10 TAG: RAIN BIRD VID SERIES <br />-WATERPROOF CONNECTION: <br />RAIN BIRD SPLICE-1 {t OF 2) <br />REMOTE CONTROL VALVE - <br />RAIN BIRO 100-ASW <br />INSTALL 6-INCH MiN. ABOVE <br />HIGHEST POINT OF DISCHARGE <br />UV RADIATION RESISTANT <br />PVC SCH 40 MALE ADAPTER <br />a (1 OF 2) <br />tNv tZ401ATi0N REsfSTAHT <br />PVC SCH 40 PIF£ <br />(1 OF 2) <br />FLNISH GRaDEfTDP OF MULCH <br />SO <br />PVC SCH 40 ELL <br />(I OF 2) <br />{ PVC LATERAL PIPE <br />/~ (I OF 2) <br />ELECTRIC REMOTE -CONTROL VALVE <br />ZITS. ASVF Series <br />Qt FINISH GRADE <br />2DMOM PROS46-PRS40-CV <br />03 LATERAL TEE OR ELL <br />®(ATERAL PIPE <br />( i/2' PVC STREET ELLS (3) <br />©SCH 80 NIPPLE <br />PROS-06--PRS40-CV <br />MP ROTATOR SPRINKLER <br />ghMhV IRRIGATION DETAIL <br />A. <br />INSTAL <br />AEDIT H <br />OF C <br />Oi 30-MICH LINEAR LENC;TH OF `lAZ_'. COIL <br />O2 WATERPROOF COMIEG2tON: <br />RM BIRD Da SERIES (1 OF 2) <br />0ID TAG <br />0LO'NF FLOVI A1.11-SIPHON VALVE: <br />RAIN BIRD ASV-LF-075 VALVE <br />"INCLUDED 1.4 XACZ-075-PRF XG) <br />PRESSURE REGULATING FIL7 R: <br />RAVLI BIRD PRF-075-R61 <br />(INCLUDED IN XACZ-075 FR? KIT,) <br />(D FVC ." dt SCH 80 1ON. <br />07FVC SCH 40 T .LE ADAPTER <br />103 IR1 RADIATION RESt»ANT PVC SCH 40 i <br />(1 OF 2) <br />v GFINISi GRAISE/TGP 0. 11.ULCa <br />i1 10 P'JC SCH 40 ELL (1 CF 21 <br />�- 0J PVC LATERAL PIPE (l OF 2; <br />XACZ-075-PRF 3/4" LOW FLOW <br />CONTROL ZONE KIT <br />MANUAL FLUSH VALVE <br />PLUMBED TO PVC OR POLY <br />Techrme6 CV DRIPLINE <br />TechGnet START CONNECTION <br />MALE ADAPTER <br />EXHAUST HEADER <br />TechtlneO TEE <br />RUAOTE CONTROL VALVE <br />WITH DiSC FILTER AND PRJ <br />AREA PERIMETER <br />SUPPLY HEADER <br />a J <br />Techline® CV IRREGULAR AREAS: Triangular ♦ate" <br />NOT TO SCALE DETAIL - C104 <br />nt�vE° e`c <br />c WE <br />Scm I" M'O <br />@RICK SUPPORTS <br />GRAVEL SULLP <br />Iso SSKCC FOR tENM <br />PVC PIPE ��- <br />PVC SCH40 ELL. (SxG <br />NEfAFIM <br />lTlla - Na SETS' <br />1 /2a Air/Vacuum Release Valve <br />(PLUmew TO Tem in!R <br />f4ttS7t � �r <br />174= <br />u0F m <br />Vl1.V£ ltRastsV-1 so <br />. <br />saw <br />- <br />ems ryaaasT> c <br />CUM* FOOT) <br />TsWine® UNE FLUSHING VALVE (PLUMBED TO PIG) PMW _ <br />INM TO WA II! <br />IRRIGATION POINT OF CONNECTION (POC) NOTES <br />IRRIGATION (POC) SHALL BE INSTALLED BY OTHERS FROM MAIN WATER SERVICE LINE BEFORE BUILDING PRESSURE <br />REGULATOR IN THE FORM OF A COPPER 1-1/4" T. IRRIGATION CONTRACTOR SHALL VERIFY MAIN WATER AND (POC) <br />LOCATION AND INSTALL ALL SLEEVES PRIOR TO ANY PAVING BEING INSTALLED. <br />eLe <br />4,n <br />Planning and Building <br />Planning Division <br />20 Civic Center Plaza <br />P.O. Box 1988 (M-20) <br />Santa Ana, CA 92702 <br />(714) 647-5804 <br />www.santa-ana.org <br />❑ Non-R sidential (0.45) <br />Estimated <br />Hydrozone Plant Irrigation Landscape Total <br />Factor" Irrigation Efficiency' ETAF Area ETAF x Water <br />#/Planting Location Method` (PF/IE) Area <br />Description (PF) (IE) (sq-ft) Used <br />(ETWU) <br />Regular Landscape Area <br />1A <br />lawn <br />front yard <br />0.8 <br />rotary <br />0.76 <br />16 <br />low water <br />south pintr <br />0.3 <br />drip <br />0.81 <br />2A <br />lawn <br />front yard <br />0.8 <br />rotary <br />0.76 <br />26 <br />low water <br />north pintr <br />0.3 <br />drip <br />0.81 <br />aecia Landscape Area <br />none T- <br />MAWA Calculations <br />(Eto) (Conv.Factor) <br />47.8 0.62 <br />1.05 <br />12( <br />0.37 <br />3& <br />1.05 <br />12( <br />0.37 <br />342 <br />rerage <br />Total <br />0.361 <br />972 <br />Average ETAF <br />for regular <br />landscape areas <br />(circle one) <br />Total Lan <br />126.32 3,744 <br />143.70 4,259 <br />126.32 3,744 <br />127.41 3,776 <br />Total <br />5241 15,524 <br />in not in <br />npliance compliance <br />- <br />I - I <br />pe Area <br />972 <br />Je ETAF <br />0.36 <br />al ETWU <br />15,524 <br />MAWA <br />15,844 <br />(ETAF x LA) = ((1-ETAF) x SLA)) = MAWA I <br />0.55 972 (0 x 0) = 15,844 �allons per year <br />total lawn area (sq. ft.) 120 24.7% <br />total landscape area (sq.ft.)972 <br />b The following table can be a ed for common plant factors: <br />IRRIGATION LEGEND <br />SYM MANUFAC DESCRIPTION <br />(FLOW) REMARKS <br />■ HUNTER MP800SR ROTATOR ADJST. ARC 6'-12' RAD (.1- .7GPM) ON PROS-06 PRS40 6" POP-UP <br />NIBCO T-580A; 1-1/4" BRASS MANUAL BALL VALVE INSTALL IN IRRIGATION BURIAL BOX <br />RAINBIRD ADSV V ELECTRIC ANTI -SIPHON VALVE INSTALL ON SCH 80 RISER, 12" ABOVE HIGHEST HEAD <br />RAINBIRD XACZ-075-PRF %" LOW FLOW KIT <br />VALVE AND PRESSURE REGULATOR/FILTER <br />Q HUNTER PRO C WITH SOLAR SYNC; INSTALL IN <br />WEATHER PROOF CABINET; VERIFY 110VAC IS PROVIDED <br />Q) HUNTER SOLAR SYNC WEATHER SENSOR; INSTALL ON EAVE OPEN TO SKY PER MANUF. SPEC'S. <br />�-�---I-ASCO//EQ. Y2 LATERAL LINE <br />SCH 40, MIN12" COVERAGE <br />LASCOIEQ. 3/a" LATERAL LINE <br />SCH 40, MINI 2" COVERAGE <br />---fft LASCO/EQ. 11, LATERAL LINE <br />SCH 40, MIN12" COVERAGE <br />--ty LASCOIEQ. 1-1/4" LATERAL LINE <br />SCH 40, MIN12" COVERAGE <br />-M-- f.ASCO/EQ. 1-1/47 MAIN LINE <br />SCH 40, MINI 8" COVERAGE <br />LASCO/EQ. SLEEVES ' (DBL. PiPE SIZE) <br />SCH 40, MINI 2" COVERAGE <br />SYM. " NETAFIM DRIPLINE COMPONENTS DESCRIPTION <br />REMARKS <br />-TLCV4-18; TECHLINE CV WITH 18" SPACING <br />STAKED 4' OC. WITH SOIL STAPLES 2" BELOW MULCH <br />i' SUPPLY HEADER, Y44" PVC <br />USE TLO75MA TO CONNECT TO PVC FEMALE ADAPTER <br />EXHAUST HEADER, Y4" PVC <br />USE TLO75MATo CONNECT TO PVC FEMALE ADAPTER <br />(9 TL050MFV 1; MANUAL FLUSH VALVE <br />INSTALL iN SMALL IRRIGATION BOX <br />N.S... LTLAVRVAIRJVACUUNI..RELIEF VALVE' 2" MPT <br />- iN-STALL IN SMA" IRRIGATION 80X . <br />VALVE IDENTIFICATION IRRIGATION SPEC'S3 METER SiZE <br />VALVE # <br />STATIC PRESSURE C>0 PS <br />GALLONS PER MINUTE GPM <br />DESIGN PRESSURE S <br />HYDROZONE ID <br />MAXIMUM FLOW 0 ° C'('tA <br />NA --- <br />Planning and Building Agency <br />tt��JJ T <br />11111 A N ( 1Z <br />I hereby certify that: w _/ I I ' v <br />(1) 1 am a professional appropriately licensed n the State of California to provide professional landscape <br />design services. <br />(2) T e landsca design and water use talc lations for the property located at <br />2-- J t ' 4r address or parcel number(s)) <br />were prepared by me or under my supervision. <br />(3) The landscape design and water use calcL IaPAi'A;dentlfied property comply with the <br />requirements of the City of Santa Ana ft, ter Efficient Landscape Ordinance (SAMC 41-1500 <br />through 1504), and the City of Santa Ana I Vater Efficient Landscape Guidelines. <br />(4) The information I have provided in this Certificate of Landscape Design is true and correct and is <br />hereby submitted in compliance with the City of Santa Ana Water Efficient Landscape Guidelines. <br />1cl2-01 <br />Print Name License Number <br />ST L.I_�,_N p ova 17 4-0 <br />Street Address ICity State Zip Code <br />E • a , L AI ADP,e 1-( 9, 6{y( QC L, , C-C) 1 LS Design Professional's Stan <br />Email Address <br />W6 Z ;� <br />Phone Number' <br />-fie Z <br />S re Date <br />r. <br />nt Factor <br />PF <br />ery low water use plant <br />0.1 <br />w water use plant <br />0.2 <br />ediutn water use plant <br />0.5 <br />gh water use plant <br />0-8 <br />n n <br />0.8 <br />ool_ spa. or other water feature <br />I.0 <br />`irrigation efficiency is derive from measurements and estimates of irrigation system <br />characteristics and manageme t practices. The minimum average irrigation efficiency for <br />ptuposes of these Guidelines i 0." 1. The following h7igation efficiency maybe obtained for the <br />listed irritation heads with an irrigation Management Efficiency of 90%: <br />rigatiun Alethod <br />iE <br />pray nozzles <br />71% <br />-gh efficiency spray nozzles <br />73% <br />ulti streamWulti trajectory <br />r tary (MSMT) nozzles <br />76 f° <br />tream rotor nozzle <br />73% <br />Ikficrospray <br />760b <br />ubblers <br />77% <br />g mutter <br />819% <br />*bssudace drip <br />81°% <br />"Landscaping for the project shall be designed to comply with the City's <br />Water Efficient Landscape Ordinance and with the Guidelines for <br />Implementation o the rater Efficient Landscape Ordinance. " <br />Plan ing Note: Average WU OLs plant factor is less than 0.3 for 75% of the plant area <br />Irrigation Notes <br />Automatic irrigation controllers are required and must use <br />evapotranspiration or soil moisture sensor data <br />Irrigation controllers shall b e of a type which does not lose <br />programming data in the e{Vent the primary power source is <br />interrupted. <br />Pressure regulators shall be ' stalled on the irrigation system to <br />ensure the dynamic press of the system is within the <br />manufacturers recommended �ssure range. <br />Manual shut-off valves (sue as a gate valve, ball valve, or <br />butterfly valve) shall be instal�ed as close as possible to the point <br />of connection of the water supl ily. <br />All irrigation emission devices must meet the requirements set in <br />the ANSI standard, ASABE/I C802-2014. "Landscape irrigation <br />Sprinkler and Emitter Stand ar " All Sprinkler heads installed in <br />the landscape must document distribution uniformity low quarter <br />of 0.65 or higher using the pr tocol defined in ASABE/ICC 802- <br />2014. <br />At the time of final inspection the permit applicant must provide <br />the owner of the property with a certificate of completion, <br />certificate of installation, irri atlon schedule and a schedule of <br />landscape and irrigation mainte iance. <br />IRRIGATION PLAN <br />PROJECT: 2 ADUS <br />512 - 514 HUYLARS LN. <br />Santa Ana, CA 92703 <br />AIN 100-573-34 <br />Applicant Contact Info: Giep Van Le <br />Design Studio <br />2971 Randolf St. <br />Huntington Park, CA 90255 <br />(323) 537-5874 <br />Owner Contact Info: Minh Tran <br />518 Huylars Ln <br />Santa Ana, CA 92703 <br />(714) 420-8153 <br />minhzzz@live.com <br />Total Landscape Area: 972 sq. ff. <br />Project Type: private/residential <br />Water Supply Type: potable <br />MANUEL. GARCIA <br />A " . . <br />228 E. CAMDEN ST. GLENDORA, CA. 91740 <br />ST. LIC. #3929 <br />(626)665.5002 / MG.LANDARCH@GMAIL.COM <br />October 21, 2025 <br />Revisions performed by DATE <br />Scale 1/8"=V-0" Sheet • of <br />0 2 4 8 12 N L-2 <br />or <br />