Laserfiche WebLink
LEGEND <br />NEW EXT, 2.9, ID 16" O,C, STUD WALL <br />O NEW 2X4 m Iro" D.G. STUD WALL <br />(2x6 -01ro" c,c, plumbing walls.) <br />I-HR FIRE ASSEMBLY WALL <br />OHARD -WIRED SMOKE DETECTOR WITH BATTERY BACKUP <br />SD (NEW CONSTRUCTION) <br />BATTERY OPERATED w EXISTING BEDROOMS AND HALLWAYS <br />HARD -WIRED CARBON MONOXIDE ALARM <br />CM W/ BATTERY BACK-UP <br />OFAN/VENT WITH 50 CFM MIN. <br />F "ENERGY STAR" WITH HUMID15TAT <br />8GFl GFCI OUTLET <br />SWITCH <br />5" RECESSED LIGHT FIXTURE <br />0 W/ DIMMER OR VACANCY SENSOR <br />TO COMPLY W/ CENC 150,O(K)Ic <br />(N) WALL MOUNT LIGHT HIGH EFFICACY (PER JAB) <br />FOR EXT. USE <br />8 CONTROLLED BY PHOTOCELL 8 MOTION SENSOR. <br />5'<II <br />(FOR MEMBRANE PENETRATION <br />IN THE 1-HR FIRE WALLS <br />SEE NOTE THIS SHEET <br />Lu .4 t1 <br />W X <br />lu P <br />tK Z z <br />LL LU <br />3_ <br />P <br />m <br />O - <br />N S" <br />m <br />(�V N O - <br />N <br />m <br />S2 <br />5�211 <br />INSTALL IX NEW CENTRAL HP 44VAC SYSTEM CAPABLE TO <br />PRODUCE THE REQUIRED MIN. ROOM <br />TEMPERATURE OF 68 DEGREE FAHRENHEIT <br />3 FT, ABOVE FLOOR LEVEL 6 2 FT FROM <br />EXTERIOR WALLS AT ALL HABITABLE ROOMS <br />AT THE DESIGN TEMPERATURE (R303.8) <br />INSTALL IX HYBRID HEAT -PUMP WATER HEATER: <br />SEE T-24 FOR GENERAL REQUIREMENT AND <br />HERS FIELD VERIFICATION REQUIREMENTS <br />KITCHEN HOOD: <br />VENTED RANGE HOOD, INCLUDING APPLIANCE —RANGE HOOD <br />COMBINATIONS SHALL MEET EITHER THE CAPTURE EFFICIENCY (CE) <br />OR THE AIRFLOW RATE SPECIFIED IN TABLE 150.0—G AS APPLICABLE. <br />PROVIDE 65% C E OR 160 CFM FOR THE ELECTRICAL RANGE <br />HVI/HVAM OF UP TO 3 SONES MAX @ 100 CFM <br />EXTERIOR OPENING: SCHEDULE <br />OPENING ID <br />COUNT <br />SIZE <br />TYPE <br />U FACTOR/SHGC <br />COMMENT <br />1 <br />4 <br />48"x48" <br />SLIDING <br />30/,23 <br />EGRESS <br />2 <br />2 <br />36"x18" <br />SLIDING <br />30/,23 <br />TEMP. PRIVACY <br />3 <br />2 <br />'12"x24" <br />SLIDING <br />30/,23 <br />4 <br />1 <br />36"X36" <br />SLIDING <br />.30/,23 <br />A <br />1 <br />-12"xOO" <br />DOOR <br />ENTRY <br />B <br />1 <br />-12"x80" <br />PATIO DOORS <br />30/,23 <br />TEMP, <br />OPENING STYLE, TRIM, ETC TO MATCH (E) <br />A 3 <br />lo <br />I <br />311-0'I � <br />I1'-6'I 5'-0I' 121-1011 <br />3'<II 51�11 i 5�211 <br />'< (N) 6POI R T`i'P, KITCHEN HOOD <br />I -PR FIRE ASSEMBLY 30" DIA LR 100 CFM MIN, <br />FLOOR PLAN <br />SCALE: 1/4" = II-O" <br />ENERGY STORAGE SYSTEM (ESS) READY: <br />A. AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED: <br />I. ESS READY INTERCONNECTION EQUIPMENT [AUTO TRANSFER SWITCH AND PANEL] WITH A MINIMUM <br />BACKED -UP CAPACITY OF 60 AMPS AND A MINIMUM OF FOUR ESS-SUPPLIED BRANCH CIRCUITS, OR <br />II. A DEDICATED, MINIMUM 1" RACEWAY FROM THE MAIN SERVICE TO A SUB PANEL THAT SUPPLIES <br />THE BRANCH CIRCUITS IN SECTION 150.0(S)(2). <br />B. A MINIMUM OF FOUR BRANCH CIRCUITS SHALL BE SUPPLIED BY THE ESS: THE REFRIGERATOR, <br />ONE LIGHTING CIRCUIT SHALL BE LOCATED NEAR THE PRIMARY EGRESS, AND AT LEAST ONE CIRCUIT <br />SHALL SUPPLY A SLEEPING ROOM RECEPTACLE OUTLET. <br />C. THE MAIN PANELBOARD SHALL HAVE A MINIMUM BUSBAR RATING OF 225 AMPERES WITH SPACE <br />TO INSTALL FUTURE ISOLATION EQUIPMENT/TRANSFER SWITCH WITHIN 3 FEET <br />MEMBRANE PENETRATION IN THE 1—HR FIRE WALLS <br />MEMBRANE PENETRATIONS OF NOT MORE THAN 2-HOUR FIRE -RESISTANCE - RATED WALLS AND PARTITIONS <br />BY STEEL ELECTRICAL BOXES THAT DO NOT EXCEED 16 SQUARE INCHES (0.0103 M2) IN AREA PROVIDED <br />THAT THE AGGREGATE AREA OF THE OPENINGS THROUGH THE MEMBRANE DOES NOT EXCEED 100 SQUARE INCHES <br />(0.0645 M2) IN ANY 100 SQUARE FEET (9.29 M2) OF WALL AREA. THE ANNULAR SPACE BETWEEN THE <br />WALL MEMBRANE AND THE BOX SHALL NOT EXCEED 1/8 INCH (3.1 MM)" <br />(N) W,H, <br />NOTES: <br />1. ALL CONCEALED WORK INSTALLED WITHOUT PERMITS MUST BE EXPOSED FOR INSPECTION TO THE SATISFACTION OF THE BUILDING INSPE TOR. <br />THIS INCLUDES METHODS OF ATTACHMENT AND ALL FOOTINGS, STRUCTURAL MEMBERS, MECHANICAL, ELECTRICAL, PLUMBING AND INSULATI N. <br />2. MECHANICAL, ELECTRICAL AND PLUMBING ARE NOT PART OF THIS PLAN REVIEW AND APPROVAL. MEP ARE SUBJECT TO BUILDING FIELD INSPECTION. <br />FO <br />Masti <br />Date: <br />CRRCPROD. ID MANUFACTURER BRAND AND MODEL PRODUCT TYPE COLOR SOLAR, REFLECTANCE TrtE,RMAL.EMHTTA.Ma SR1 MORE INFO <br />: V V <br />INITIAL.: 3 YEAR A INMAL A 3 YEAR A INMAL A 3 YEAR A <br />F <br />I <br />C65S-0C5S Cer-a i-eec _-C Landmark5olaris® Crystal Gray I <br />Landmark Pro'S Crystal Gray <br />Asphalt Shi Grey 0.27 0.26 0.93 0.90 29 27 <br />ngle <br />ATTIC VENT CALCULATIONS: <br />REQUIRED VENT=6O6/150X144 = 115 SQ. IN. <br />PROVIDE (6) 12"X24" DORMER STYLE VENTS <br />W/ SO SQ.IN, EACH <br />8 4- 14XIO GABLE ATTIC VENT <br />W/ 100 SQ,IN, NET OPENING EACH, <br />TOTAL NFV: (6X80) + (4X100) = S80 SQ.IN. <br />PROPERTY LINE <br />------------- <br />CLASS 'A' ASPHALT SHINGLES <br />CERTAINTEED ICC ESR-1389 <br />CRRC-0668-0058 <br />OR APPROVED EQ. <br />OVER 2-15* FELTS TO MATCH EXISTING <br />OVER 3/4" PLYWOOD STRUCT. PANEL <br />(PLYWOOD CDX OR OSB) <br />W/SD a 6:6:12 COMMON NAILS TYP. <br />� O <br />RAIN GUTTERS TYP. <br />II <br />II <br />III ' <br />ill ; <br />II <br />- II <br />II <br />' III <br />i II; <br />II <br />II <br />III , <br />II <br />III I <br />I <br />II <br />I I,I <br />I <br />I III <br />I <br />III <br />I I <br />II <br />III I <br />II ' to <br />'II ' ll: 0 <br />II � <br />III I <br />III I <br />I I,I <br />III <br />i JIB <br />II <br />I I,I <br />I III <br />tu <br />Q_ <br />0 <br />� III <br />II <br />i Ili <br />II <br />III � <br />II <br />ill i N <br />II <br />III , <br />I II, <br />III � <br />III I <br />II <br />I II, <br />I III <br />II <br />III , <br />, III <br />III , <br />III , <br />, III <br />, III <br />'Il I <br />III , <br />I II' <br />, III <br />III. i -' -'- - - - - - - - - - - - - - <br />p <br />- - - - - - - - - - - - - — - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - T - - - - <br />- - -'- - -'- - - - - - - - - - - -- - - - - - - - - III <br />II, <br />- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br />ROOF FLAN <br />SCALE: 1/4 = I -O <br />­:jRAIN GUTTERS TYP. <br />PV SOLAR SYSTEM <br />DESIGN AND PERMITTING <br />BY OTHERS <br />SOLAR ENERGY SYSTEM SHALL COMPLY WITH SECTION R324, <br />IN ADDITIONAL, ELECTRICAL PORTION OF SOLAR PV SYSTEMS <br />SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH <br />THE CALIFORNIA ELECTRICAL CODE <br />THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS OF THE JOB PRIOR TO STARTING CONSTRUCTION. <br />CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR INCONSISTENCIES. <br />DO NOT SCALE DRAWINGS, WHERE NO DIMENSIONS ARE PROVIDED, CONSULT WITH ARCHITECT FOR CLARIFICATION BEFORE <br />PROCEEDING WITH THE WORK, <br />THESE DESIGN DRAWINGS ARE FOR REVIEW ONLY AND ARE NOT FOR CONSTRUCTION UP UNTIL APPROVED BY PLANNING <br />AND BUILDING DEPARTMENT AND A BUILDING PERMIT 16 OBTAINED FROM ALL RELATED DEPARTMENTS. <br />CITY OF SANTA ANA <br />iZf ency <br />AP(HITE(fl <br />A"Ro"M <br />PERMIII(!SSUAI <br />1:00 <br />ID: <br />OMIT UmBSKY <br />UUM50 ORNIUCT <br />5739 Konan PD. 133 <br />ACOURA HILLS, (A 91301 <br />T&L: (818) 674-6034 <br />Fax: (888) 202-7711 <br />LA.AR HITNT e(NA1L (OM <br />Residential: <br />New Construction <br />Remodeling <br />Additions <br />CA Energy Title-24 <br />CA Green Building <br />Low Impact Development <br />11� V J <br />O O <br />O O <br />V <br />VJ v, wn <br />l� N <br />W <br />n III <br />1 'W <br />T <br />o AF?cy�rF <br />v AMIT �J1 <br />KY <br /># No. C-30 <br />NREN. <br />� <br />OF UFO <br />Monday, October 21, 2025 <br />SOLE AS SHOWN <br />DRAWN AoDD <br />JOB <br />SHEET <br />0 <br />SCE <br />z <br />U <br />d <br />p <br />