Mandatory Measures Summary <br />Residential , . <br />Site Address:le,11 MAG AN-l A Enforcement Agency: <br />MF-1R <br />(Page 1 of 3) <br />Date: ,11'611 1 <br />NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, <br />regardless ofthe compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, <br />CF-1 R-ADD, or CF-I R-ALT Form) shall supersede the items marked with an asterisk e) below. This Mandatory Measures <br />Summary shall be incorporated into the permit documents and the applicablefeatures shall be considered by all parties as minimum <br />component performance specijications whether they are shown elsewhere in the documents or in this summary. Submit all <br />applicable sections of the MF- 1 R Form with plans. <br />DESCRIPTION <br />Building Envelope Measures: <br />§116(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage, <br />§116(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient <br />(SHGC), and infiltration that meets the requirements of §10-111(a) <br />§117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. <br />§118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. <br />§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of <br />a Cool Roof is specified on the CF- 1 R Form. <br />*§150(a): Minimum R-19 insulation in wood-frame ceiling or equivalent U-factor. <br />§150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. <br />*§150(c): Minimum R-13 insulation in wood-frame wall or equivalent U-factor. <br />*§150(d): Minimum R-13 insulation in raised wood-frame floor or equivalent U-factor. <br />§150(ft Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF-IR Form. <br />§150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. <br />§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no <br />greater than 2.0 penn/inch and shall be protected from physical damage and UV light deterioration. <br />Fireplaces, Decorative Gas Appliances and Gas Log Measures: <br />§150(e)lA: Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox. <br />§150(e)1 B: Masonry or factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped <br />with a with a readily accessible, operable, and tight-fitting damper and or a combustion-air control device. <br />§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the <br />building, are prohibited. <br />Space Conditioning, Water Heating and Plumbing System Measures: <br />§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. <br />§113(05: Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release valve, <br />backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. <br />§115: Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces, household cooking appliances (appliances with an <br />electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. <br />§150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. <br />§150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c) <br />§1500)1 A : Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with <br />insulation having an installed thermal resistance of R- 12 or greater. <br />§1500)]B: Unfired storage tanks, such as storage tanks or backup tanks for solar water-heating system, or other indirect hot water tanks have R-12 <br />external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. <br />§1500)2: First 5 feet of hotand cold water pipes closest to water heater tank, non-recirculating systems, and entire length of recirculating sections <br />of hot water pipes are insulated per Standards Table 150-B. <br />§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank <br />shall be insulated to Table 150-B and Equation 150-A. <br />§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems > 15 psi, meets the requirements of Standards Table 123-A. <br />§1500)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. <br />§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. <br />2008 Residential Compliance Forms August 2009