Laserfiche WebLink
D-1 <br />HOLOMALIA RESIDENCE <br />SHEET <br />REV DATE DESCRIPTION <br />05/02/24A <br />T H E R E S H A L L B E N O C H A N G E S O R D E V I A T I O N O N T H E S E P L A N S W I T H O U T T H E C O N S E N T O F PL A N A N D P E R M I T I N C . N O T E S A N D D E T A I L S O N T H E D R A W I N G S S H A L L T A K E P R E C E D E N C E O V E R G E N E R A L N O T E S A N D T Y P I C A L D E T A I L S . W H E RE N O D E T A I L S S H O W N O R N O T E D O N T H E D R A W I N G S , T H E D E T A I L S S H A L L B E T H E S A M E A S F O R O T H E R S I M I L A R W O R K .C O N T R A C T O R S H A L L V E R I F Y A L L P L A N S , E X I S T I N G D I M E N S I O N S A N D F I E L D C O N D I T I O N S O N T H E J O B S I T E A N D S H A L L I M M E D I A T E L Y N O T I F Y T O P L A N A N D P E R MI T I N C A N Y D I S C R E P A N C I E S I N W R I T I N G P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K O R B E R E S P O N S I B L E F O R S A ME . <br />TH <br />E <br />S <br />E <br /> <br /> <br />D <br />E <br />S <br />I <br />G <br />N <br />S <br />, <br />D <br />R <br />A <br />W <br />I <br />N <br />G <br />S <br /> <br />A <br />N <br />D <br /> <br />S <br />P <br />E <br />C <br />I <br />F <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br />S <br /> <br />A <br />R <br />E <br /> <br />T <br />H <br />E <br /> <br />P <br />R <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />A <br />N <br />D <br /> <br />C <br />O <br />P <br />Y <br />R <br />I <br />G <br />H <br />T <br /> <br />O <br />F <br /> <br />P <br />L <br />A <br />N <br /> <br />A <br />N <br />D <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />I <br />N <br />C <br /> <br />A <br />N <br />D <br /> <br />S <br />H <br />A <br />L <br />L <br /> <br />N <br />O <br />T <br /> <br />B <br />E <br /> <br />U <br />S <br />E <br />D <br /> <br />I <br />N <br /> <br />C <br />O <br />N <br />N <br />E <br />C <br />T <br />I <br />O <br />N <br /> <br />W <br />I <br />T <br />H <br /> <br />A <br />N <br />Y <br /> <br />O <br />T <br />H <br />E <br />R <br /> <br />W <br />O <br />R <br />K <br /> <br />E <br />X <br />C <br />E <br />P <br />T <br /> <br />B <br />Y <br /> <br />A <br />G <br />R <br />E <br />E <br />M <br />E <br />N <br />T <br /> <br />W <br />I <br />T <br />H <br /> <br />P <br />L <br />A <br />N <br /> <br />A <br />N <br />D <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />I <br />N <br />C <br />. <br /> <br />B <br />Y <br /> <br />U <br />S <br />I <br />N <br />G <br /> <br />T <br />H <br />E <br />S <br />E <br /> <br />P <br />L <br />A <br />N <br />S <br />, <br /> <br />T <br />H <br />E <br /> <br />U <br />S <br />E <br />R <br /> <br />A <br />G <br />R <br />E <br />E <br />S <br /> <br />T <br />O <br /> <br />R <br />E <br />L <br />E <br />A <br />S <br />E <br /> <br />P <br />L <br />A <br />N <br /> <br />A <br />N <br />D <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />I <br />N <br />C <br /> <br />F <br />R <br />O <br />M <br /> <br />A <br />N <br />Y <br /> <br />A <br />N <br />D <br /> <br />A <br />L <br />L <br /> <br />C <br />L <br />A <br />I <br />M <br />S <br />, <br /> <br />L <br />I <br />A <br />B <br />I <br />L <br />I <br />T <br />I <br />E <br />S <br />, <br /> <br />S <br />U <br />I <br />T <br />S <br />, <br /> <br />A <br />N <br />D <br /> <br />D <br />E <br />M <br />A <br />N <br />D <br />S <br /> <br />O <br />N <br /> <br />A <br />C <br />C <br />O <br />U <br />N <br />T <br /> <br />O <br />F <br /> <br />A <br />N <br />Y <br /> <br />I <br />N <br />J <br />U <br />R <br />Y <br />, <br /> <br />D <br />A <br />M <br />A <br />G <br />E <br /> <br />O <br />R <br /> <br />L <br />O <br />S <br />S <br /> <br />O <br />R <br /> <br />P <br />E <br />R <br />S <br />O <br />N <br />S <br /> <br />O <br />R <br /> <br />P <br />R <br />O <br />P <br />E <br />R <br />T <br />Y <br />, <br /> <br />I <br />N <br />C <br />L <br />U <br />D <br />I <br />N <br />G <br /> <br />I <br />N <br />J <br />U <br />R <br />Y <br /> <br />O <br />R <br /> <br />D <br />E <br />A <br />T <br />H <br />, <br /> <br />O <br />R <br /> <br />E <br />C <br />O <br />N <br />O <br />M <br />I <br />C <br /> <br />L <br />O <br />S <br />S <br />E <br />S <br />, <br /> <br />A <br />R <br />I <br />S <br />I <br />N <br />G <br /> <br />O <br />U <br />T <br /> <br />O <br />F <br /> <br />T <br />H <br />E <br /> <br />U <br />S <br />E <br /> <br />O <br />F <br /> <br />T <br />H <br />E <br />S <br />E <br /> <br />P <br />L <br />A <br />N <br />S <br />. <br />B <br />SKETCH FOR REVIEW <br />C <br />90PD FOR APPROVALD <br />0 100PD FOR SUBMITTAL <br />90PD FOR REVIEW <br />PROPERTY ADDRESS: <br />922 W PARK LN, <br />SANTA ANA, CA 92706 <br />PLAN AND PERMIT INC. <br />ARCHITECTURAL DESIGN SERVICES <br />9891 IRVINE CENTER DR #200 <br />IRVINE, CA 92618 <br />(714)-715-0923 <br />biz@planandpermit.com <br />LOCATION QR CODE: <br />STATE OF CAL IFORNIA <br />EXP. DATE <br />L <br />I <br />C <br />E <br />NS E D A R C H <br />I <br />T <br />E <br />C <br />T <br />C - 34643 <br />06/30/2027 <br />SIGNATURE <br />PAUL SAN GEMINO <br />07/09/24 <br />07/23/24 <br />07/10/25 <br />1 PC109/29/25 <br />06/09/24 SKETCH FOR REVIEW <br />FOR PLANNING REVIEWE08/20/24 <br />F 09/15/24 FOR PLANNING REVIEW <br />G 02/06/25 FOR PLANNING REVIEW <br />H 02/21/25 FOR PLANNING REVIEW <br />I 04/19/25 FOR PLANNING REVIEW <br />J 05/01/25 FOR PLANNING REVIEW <br />DETAILS <br />1 N.T.S.N.T.S. <br />EXTERIOR WALL. STUCCO <br />CEMENT STUCCO <br />EXTERIOR SHEATHING <br />2X WALL <br />(2) LAYERS BUILDING PAPER <br />(WEATHER-RESISTANT TYPE 1 GRADE <br />D STYLE 2) <br />GALVANIZED METAL LATH <br />INSULATION PER T24 REPORT <br />NOTE: REFER TO STRUCTURAL DWGS FOR <br />SHEAR WALL LOCATION AND SCHEDULE. <br />EXTERIORINTERIOR <br />(1) LAYERS 5/8" GYPSUM BOARD <br />2 3N.T.S. <br />NOTE: REFER TO PLAN FOR PARTITION TYPE.NOTE: REFER TO PLAN FOR PARTITION TYPE. <br />PARTITION WALL PARTITION WALL @ WET LOCATION <br />2X WALL <br />GWB <br />GWB <br />GWB <br />2X WALL <br />CERAMIC TILE/NON ABSORBENT WALL <br />3/16" FRAMING THINSET <br />1/2" CEMENT BACKER BOARD <br />WATER PROOFING AND CRACK ISOLATION <br />MEMBRANE OVER BACKER BOARD <br />TILE GROUT WHERE OCCURS <br />N.T.S. <br />HEIGHT FOR ELECTRICAL RECEPTACLE OUTLETS, SWITCHES, DOORBELL <br />BUTTONS, INCLUDING HVAC CONTROLS <br />SECTION R327 AGING-IN-PLACE DESIGN AND FALL PREVENTION <br />R327.1.1 REINFORCEMENT FOR GRAB BARS <br />AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCE WITH THIS SECTION. <br />WHERE THERE IS NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE BATHROOM ON THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL <br />COMPLY WITH THIS SECTION. <br />1.REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. <br />2.REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH (51 MM BY 203 MM) NOMINAL LUMBER. [11/2 INCH BY 71/4 INCH (38 MM BY 184 MM) <br />ACTUAL DIMENSION] OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BE <br />LOCATED BETWEEN 32 INCHES (812.8 MM) AND 391/4 INCHES (997 MM) ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. <br />3.WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. <br />4.SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. <br />5.BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK <br />WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE <br />THAN 6 INCHES (152.4 MM) ABOVE THE BATHTUB RIM. <br />EXCEPTIONS: <br />1.WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL <br />HAVE PROVISIONS FOR INSTALLATION OF FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY <br />THE ENFORCING AGENCY. <br />2.REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR PRE-FABRICATED SHOWER ENCLOSURES AND BATHTUB WALL PANELS WITH <br />INTEGRAL FACTORY-INSTALLED GRAB BARS OR WHEN FACTORY-INSTALLED REINFORCEMENT FOR GRAB BARS IS PROVIDED. <br />3.SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND/OR GRAB BARS SHALL BE PERMITTED, PROVIDED <br />REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />4.BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS DO NOT PERMIT THE INSTALLATION OF REINFORCEMENT SHALL BE <br />PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS ADJACENT TO THE BATHTUB OR AN ALTERNATE <br />METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />5.REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR BATHTUBS AND WATER CLOSETS INSTALLED ON CONCRETE SLAB FLOORS. <br />INTERIOR <br />HEIGHTS ARE TO FINISH FLOOR <br />EXTERIOR <br />DOORBELL HEIGHT IS FROM <br />FLOOR OR LANDING TO TOP <br />DOORBELL ASSEMBLY <br />SECTION R327 AGING-IN-PLACE DESIGN AND <br />FALL PREVENTION <br />R327.1.2 ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL <br />HEIGHTS <br />ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS <br />(INCLUDING CONTROLS FOR HEATING, VENTILATION AND AIR <br />CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE <br />LOCATED NO MORE THAN 48 INCHES (1219.2 MM) MEASURED FROM <br />THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15 INCHES (381 <br />MM) MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE <br />THE FINISH FLOOR. <br />EXCEPTIONS: <br />1.DEDICATED RECEPTACLE OUTLETS; FLOOR RECEPTACLE OUTLETS; <br />CONTROLS MOUNTED ON CEILING FANS AND CEILING LIGHTS; <br />AND CONTROLS LOCATED ON APPLIANCES. <br />2.RECEPTACLE OUTLETS REQUIRED BY THE CALIFORNIA ELECTRICAL <br />CODE ON A WALL SPACE WHERE THE DISTANCE BETWEEN THE <br />FINISHED FLOOR AND A BUILT-IN FEATURE ABOVE THE FINISH <br />FLOOR, SUCH AS A WINDOW, IS LESS THAN 15 INCHES (381 MM). <br />R327.1.3 INTERIOR DOORS <br />EFFECTIVE JULY 1, 2024, AT LEAST ONE BATHROOM AND ONE <br />BEDROOM ON THE ENTRY LEVEL SHALL PROVIDE A DOORWAY WITH <br />A NET CLEAR OPENING OF NOT LESS THAN 32 INCHES (812.8 MM), <br />MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 <br />DEGREES FROM THE CLOSED POSITION; OR, IN THE CASE OF A TWO- <br />OR THREE-STORY SINGLE FAMILY DWELLING, ON THE SECOND OR <br />THIRD FLOOR OF THE DWELLING IF A BATHROOM OR BEDROOM IS <br />NOT LOCATED ON THE ENTRY LEVEL. <br />R327.1.4 DOORBELL BUTTONS <br />DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT <br />EXCEED 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR <br />LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON <br />ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER <br />FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48 INCHES (1219.2 <br />MM) MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A <br />STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE <br />PROVIDED AT A HEIGHT NOT EXCEEDING 48 INCHES (1219.2 MM) <br />ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF <br />THE DOORBELL BUTTON OR CONTROL. <br />SHOWER ENCLOSURE <br />SIDE WALL BACK WALL CONTROLS WALL <br />SIDE WALL BACK WALL CONTROLS WALL <br />BATHTUB OR TUB/SHOWER <br />SIDE WALL BACK WALL <br />EXAMPLE LOCATION OF 2X8 <br />REINFORCEMENT FOR FUTURE GRAB BARS <br />LA <br />V <br />. <br />WATER CLOSET ADJACENT TO ONE SIDE WALL <br />AND BACK WALL <br />EXAMPLE LOCATION OF 2X8 <br />REINFORCEMENT FOR FUTURE GRAB BARS <br />LAV. <br />WATER CLOSET ADJACENT TO TWO SIDE WALLS <br />6 N.T.S. <br />OUTLETS, DOORS & CONTROLS5N.T.S. <br />GRAB BAR REINFORCEMENT <br />CEMENT STUCCO <br />EXTERIOR SHEATHING <br />(2) LAYERS BUILDING PAPER <br />(WEATHER-RESISTANT TYPE 1 GRADE <br />D STYLE 2) <br />GALVANIZED METAL LATH <br />INTERIOR FINISH <br />4 N.T.S. <br />FIXTURE PENETRATION <br />BED EXTERIOR FLANGE <br />IN SEALANT <br />PLASTER RING <br />PLASTER RINGS SHOULD BE AFFIXED OVER THE <br />SERVICE BOX TO BRING THE FACE OF THE <br />BOX FLUSH WITH THE ADHERED CONCRETE <br />MASONRY VENEER. BED THE EXTERIOR FLANGE <br />IN SEALANT. WATER RESISTIVE BARRIER SHOULD <br />BE INSTALLED SNUGLY AROUND THE PLASTER <br />RING FLANGE. <br />FIXTURE PER PLUMBING PLAN <br />1 HOUR FIRE RATED WALL <br />INSULATION PER T24 REPORT <br />5/8" TYPE X GWB. <br />5/8" TYPE X GWB. <br />INTERIOR INTERIOR <br />GYPSUM WALLBOARD, WOOD STUDS <br />FIRE DESIGN: <br />·ONE LAYER 5/8″ TYPE X GYPSUM WALLBOARD <br />OR GYPSUM VENEER BASE APPLIED PARALLEL <br />OR AT RIGHT ANGLES TO EACH SIDE OF 2 × 4 <br />WOOD STUDS 24″ O.C. WITH 6D COATED NAILS, <br />1-7/8″ LONG, 0.0915″ SHANK, 1/4″ HEADS, 7″ <br />O.C. JOINTS STAGGERED 24″ ON OPPOSITE <br />SIDES. (LOAD-BEARING) <br />THICKNESS: 4-7/8″ (Fire) <br />APPROX. WEIGHT: 7 psf (Fire) <br />FIRE TEST: UL R3501-47, -48, 9-17-65, <br />UL DESIGN U309, <br />UL R1319-129, 7-22-70, <br />UL DESIGN U314 <br />STC : N/A <br />GA FILE NO. WP 3510 <br />7 N.T.S.8 N.T.S. <br />EXTERIOR WALL. BOARD AND BATTEN <br />EXTERIOR SHEATHING <br />INSULATION PER T24 REPORT <br />(2) LAYERS BUILDING PAPER <br />(WEATHER-RESISTANT TYPE 1 GRADE <br />D STYLE 2) <br />INTERIOR EXTERIOR <br />NOTE: REFER TO STRUCTURAL DWGS FOR <br />SHEAR WALL LOCATION AND SCHEDULE. <br />2X WALL <br />BOARD AND BATTEN OR HARDIE <br />BOARD, ICC-ESR-2290. <br />GWB <br />11 N.T.S. <br />1-1/4" <br />1-1/2' <br />2" <br />3" <br />FIXTURE <br />TOILET <br />KITCHEN SINK <br />LAVATORY <br />SHOWER <br />BATHTUB <br />2'-6" <br />3'-6" <br />5'-0" <br />6'-0" <br />WASTE LINE SIZE <br />3” MINIMUM <br />2” MINIMUM <br />1-1/4” MINIMUM <br />2” MINIMUM <br />1-1/2” MINIMUM <br />TRAP ARM PIPE SIZE TRAP TO VENT DISTANCE <br />VENT <br />VENT <br />KITCHEN SINK <br />CLEAN-OUT <br />TOILET <br />LAVATORY <br />SANITARY "T" <br />BATHTUB <br />COMBINATION "Y" <br />AND 1 <br />8 BEND <br />DIRECTION OF FLOW <br />CLEAN-OUT <br />·VERTICAL DRAINAGE LINES CONNECTING WITH HORIZONTAL DRAINAGE LINES SHALL ENTER THROUGH 45 DEGREE WYE <br />BRANCHES, COMBINATION WYE AND 1/8 BEND BRANCHES, OR OTHER APPROVED FITTINGS OF EQUIVALENT SWEEP. <br />·HORIZONTAL DRAINAGE LINES CONNECTING WITH OTHER HORIZONTAL DRAINAGE LINES SHALL ENTER THROUGH 45 <br />DEGREE WYE BRANCHES, COMBINATION WYE AND 1/8 BEND BRANCHES, OR OTHER APPROVED FITTINGS OF <br />EQUIVALENT SWEEP. <br />·HORIZONTAL DRAINAGE LINES, CONNECTING WITH A VERTICAL STACK, SHALL ENTER THROUGH 45-DEGREE WYE <br />BRANCHES, 60-DEGREE WYE BRANCHES, COMBINATION WYE AND 1/8 BEND BRANCHES, SANITARY TEE BRANCHES, OR <br />OTHER APPROVED FITTINGS OF EQUIVALENT SWEEP. <br />·HORIZONTAL TRAP ARMS, CONNECTING WITH A VERTICAL STACK OR WASTE, SHALL ENTER THROUGH SANITARY TEE <br />BRANCHES. A TRAP ARM IS THAT PORTION OF A FIXTURE DRAIN BETWEEN A TRAP AND A VENT. SEE TABLE BELOW FOR <br />HORIZONTAL TRAP ARM DISTANCES. THE SIZE OF VENT PIPING SHALL BE DETERMINED FROM ITS LENGTH AND THE <br />TOTAL NUMBER OF FIXTURE UNITS CONNECTED THERETO. IN ADDITION, THE DRAINAGE PIPING OF EACH BUILDING AND <br />EACH CONNECTION TO A PUBLIC SEWER SHALL BE VENTED BY MEANS OF ONE OR MORE VENT PIPES, THE AGGREGATE <br />CROSS-SECTIONAL AREA OF WHICH SHALL NOT BE LESS THAN THAT OF THE LARGEST BUILDING SEWER. <br />TYPICAL PLUMBING WASTE AND VENT SYSTEM <br />10 N.T.S. <br />COMPLIANCE <br />·CULUS CERTIFIED TYPE IC SUITABLE FOR DIRECT CONTACT WITH AIR PERMEABLE INSULATION <br />·NOT RECOMMENDED FOR USE IN DIRECT CONTACT WITH SPRAY FOAM INSULATION (REFERENCE <br />NEMA LSD57-2013) <br />·WET LOCATION LISTED AND IP44 INGRESS PROTECTION <br />·AIRTIGHT PER ASTM-E283-04 <br />·SUITABLE FOR USE IN CLOTHES CLOSETS WHEN INSTALLED IN ACCORDANCE WITH THE NEC 410.16 <br />SPACING REQUIREMENTS <br />·EMI/RFI EMISSIONS PER FCC 47CFR PART 15 CONSUMER LIMITS <br />·CONTAINS NO MERCURY OR LEAD AND ROHS COMPLIANT <br />·PHOTOMETRIC TESTING IN ACCORDANCE WITH IES LM-79-08 <br />·LUMEN MAINTENANCE PROJECTIONS IN ACCORDANCE WITH IES LM-80-08 AND TM-21-11 <br />·STATE OF CALIFORNIA TITLE 24 HIGH EFFICACY <br />·LED COMPLIANCE UNDER JA8, REFERENCE MODERNIZED APPLIANCE EFFICIENCY DATABASE <br />SYSTEM (MAEDBS) FOR 2016 JA8 HIGH EFFICACY LIGHTING <br />·ENERGY STAR® CERTIFIED (REFERENCE “CERTIFIED LIGHT FIXTURES” DATABASE) <br />HALO LED LIGHT HLB SERIES (OR APPROVED EQUAL)9 <br />WALL MOUNTED OUTDOOR LIGHT (1-LIGHT BLACK DUSK <br />TO DAWN OUTDOOR WALL SCONCE GOOSENECK BARN <br />MOTION SENSOR WALL LIGHTS OR APPROVED EQUAL) <br />N.T.S. <br />Docusign Envelope ID: 19C98200-DBD2-46D9-ADCA-E58071C813C9