Laserfiche WebLink
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)341 @ 2"4922 (2.25")Passed (7%)--1.0 D + 1.0 Lr (All Spans) <br />Shear (lbs)313 @ 9"2888 Passed (11%)1.25 1.0 D + 1.0 Lr (All Spans) <br />Moment (Ft-lbs)1200 @ 6' 7 5/16"2151 Passed (56%)1.25 1.0 D + 1.0 Lr (All Spans) <br />Live Load Defl. (in)0.254 @ 6' 9 9/16"0.443 Passed (L/629)--1.0 D + 1.0 Lr (All Spans) <br />Total Load Defl. (in)0.491 @ 6' 9 5/8"0.665 Passed (L/325)--1.0 D + 1.0 Lr (All Spans) <br />Member Length : 13' 5" <br />System : Roof <br />Member Type : Flush Beam <br />Building Use : Residential <br />Building Code : IBC 2021 <br />Design Methodology : ASD <br />Member Pitch : 0/12 <br />•Deflection criteria: LL (L/360) and TL (L/240). <br />•Applicable calculations are based on NDS. <br />• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Roof Live Wind Factored Accessories <br />1 - Column - DF 3.50"2.25"1.50"167 177 -177 344/-6 1 1/4" Rim Board <br />2 - Column - DF 3.50"2.25"1.50"166 176 -176 343/-6 1 1/4" Rim Board <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)Continuous <br />Bottom Edge (Lu)End Bearing Points <br />• Side loads are assumed to not induce cross-grain tension. <br />Dead Roof Live Wind <br />Vertical Loads Location (Side)Tributary <br />Width <br />(0.90)(1.25)(1.60)Comments <br />0 - Self Weight (PLF)1 1/4" to 13' 6 1/4"N/A 4.9 ---- <br />1 - Uniform (PSF)0 to 13' 7 1/2" (Front)1' 4"12.0 16.0 -16.0 RR <br />2 - Point (lb)5' 1" (Front)N/A 29 37 -37 Linked from: <br />(N)RB4, Support 1 <br />3 - Point (lb)9' (Front)N/A 21 26 -26 Linked from: <br />(N)RB5, Support 1 <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ <br />document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). <br />MEMBER REPORT PASSED <br />Roof, (N)RB6 <br />1 piece(s) 4 x 6 DF No.2 <br />Page 94 of 290