Laserfiche WebLink
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)1518 @ 2"4922 (2.25")Passed (31%)--1.0 D + 1.0 Lr (All Spans) <br />Shear (lbs)1254 @ 1' 3/4"4856 Passed (26%)1.25 1.0 D + 1.0 Lr (All Spans) <br />Moment (Ft-lbs)2341 @ 3' 3"5615 Passed (42%)1.25 1.0 D + 1.0 Lr (All Spans) <br />Live Load Defl. (in)0.032 @ 3' 8 3/16"0.240 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) <br />Total Load Defl. (in)0.060 @ 3' 8 1/8"0.360 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) <br />Member Length : 7' 5 1/4" <br />System : Roof <br />Member Type : Flush Beam <br />Building Use : Residential <br />Building Code : IBC 2021 <br />Design Methodology : ASD <br />Member Pitch : 0/12 <br />•Deflection criteria: LL (L/360) and TL (L/240). <br />•Applicable calculations are based on NDS. <br />• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Roof Live Wind Factored Accessories <br />1 - Column - DF 3.50"2.25"1.50"720 826 -840 1546/-72 1 1/4" Rim Board <br />2 - Column - DF 3.50"3.50"1.50"540 641 -655 1181/-69 Blocking <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)Continuous <br />Bottom Edge (Lu)End Bearing Points <br />• Side loads are assumed to not induce cross-grain tension. <br />Dead Roof Live Wind <br />Vertical Loads Location (Side)Tributary <br />Width <br />(0.90)(1.25)(1.60)Comments <br />0 - Self Weight (PLF)1 1/4" to 7' 6 1/2"N/A 8.2 ---- <br />1 - Uniform (PLF)0 to 7' 6 1/2" (Front)N/A 39.0 51.8 -53.3 Linked from: <br />(N)RR1, Support 3 <br />2 - Uniform (PLF)0 to 7' 6 1/2" (Front)N/A 77.3 99.0 -101.3 Linked from: <br />(N)RR2, Support 2 <br />3 - Point (lb)1' 2" (Front)N/A 161 165 -165 Linked from: <br />(N)RB3, Support 2 <br />4 - Point (lb)2' 4" (Front)N/A 161 165 -165 Linked from: <br />(N)RB3, Support 2 <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ <br />document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). <br />MEMBER REPORT PASSED <br />Roof, (N)RB12 <br />1 piece(s) 4 x 10 DF No.2 <br />Page 100 of 290