Laserfiche WebLink
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)1063 @ 2"4922 (2.25")Passed (22%)--1.0 D + 1.0 L (All Spans) <br />Shear (lbs)859 @ 10 3/4"3045 Passed (28%)1.00 1.0 D + 1.0 L (All Spans) <br />Moment (Ft-lbs)2126 @ 4' 2 3/4"2958 Passed (72%)1.00 1.0 D + 1.0 L (All Spans) <br />Live Load Defl. (in)0.106 @ 4' 2 3/4"0.271 Passed (L/917)--1.0 D + 1.0 L (All Spans) <br />Total Load Defl. (in)0.142 @ 4' 2 3/4"0.406 Passed (L/686)--1.0 D + 1.0 L (All Spans) <br />Member Length : 8' 3" <br />System : Floor <br />Member Type : Flush Beam <br />Building Use : Residential <br />Building Code : IBC 2021 <br />Design Methodology : ASD <br />•Deflection criteria: LL (L/360) and TL (L/240). <br />•Applicable calculations are based on NDS. <br />• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Floor Live Factored Accessories <br />1 - Column - DF 3.50"2.25"1.50"274 815 1089 1 1/4" Rim Board <br />2 - Beam - DF 3.50"2.25"1.50"274 815 1089 1 1/4" Rim Board <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)8' o/c <br />Bottom Edge (Lu)End Bearing Points <br />• Side loads are assumed to not induce cross-grain tension. <br />Dead Floor Live <br />Vertical Loads Location (Side)Tributary <br />Width <br />(0.90)(1.00)Comments <br />0 - Self Weight (PLF)1 1/4" to 8' 4 1/4"N/A 6.4 -- <br />1 - Uniform (PLF)0 to 8' 5 1/2" (Front)N/A 38.3 126.0 Linked from: <br />(N)CJ1, Support 2 <br />2 - Uniform (PLF)0 to 8' 5 1/2" (Front)N/A 20.3 66.8 Linked from: <br />(N)CJ2, Support 1 <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ <br />document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). <br />MEMBER REPORT PASSED <br />CLG, (N)CB17 <br />1 piece(s) 4 x 8 DF No.2 <br />Page 163 of 290