My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
922 W Park Ln - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Park Ln
>
922 W Park Ln
>
922 W Park Ln - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:30 AM
Creation date
2/13/2026 5:00:26 AM
Metadata
Fields
Template:
Plan
Permit Number
101124745
Full Address
922 W Park Ln
Street Number
922
Street Direction
W
Street Name
Park
Street Suffix
Ln
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (12' 1"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi <br />(+/- 0.18), Effective Wind Area determined using full member span and trib. width. <br />• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. <br />Wind <br />Lateral Load Location Tributary Width (1.60)Comments <br />1 - Uniform (PSF)Full Length 4' 6"16.5 <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ <br />document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />Page 178 of 290