Laserfiche WebLink
(E) FP <br />(E) LIVING ROOM <br />(E) MASTER BEDROOM <br />(E) BEDROOM <br />(E) GARAGE <br />(E) BEDROOM <br />(E <br />) <br /> <br />B <br />A <br />T <br />H <br />R <br />O <br />O <br />M <br />(E) CLOSET <br />(E) CLOSET <br />(E) CLOSET <br />(E) STORE <br />ATTIC <br />FAU AA <br />(N) ENTRY <br />8' CLG <br />(N) DINING ROOM <br />(N) KITCHEN <br />8' CLG <br />(N) FRONT PORCH <br />(N) LIVING ROOM <br />(E <br />) <br /> <br />M <br />A <br />S <br />T <br />E <br />R <br /> <br />B <br />A <br />T <br />H <br />CA <br /> 2 <br />4 <br />" <br />X <br />1 <br />8 <br />" <br />. <br />CA <br /> 2 <br />4 <br />" <br />X <br />1 <br />8 <br />" <br />. <br />W <br />D <br />REFD/W <br />(N) <br />LAUNDRY/PANTRY <br />(E) FP <br />(E) LIVING ROOM <br />(E) MASTER BEDROOM <br />(E) BEDROOM <br />(E) GARAGE <br />(E) BEDROOM <br />(E <br />) <br /> <br />B <br />A <br />T <br />H <br />R <br />O <br />O <br />M <br />(E) CLOSET <br />(E) CLOSET <br />(E) CLOSET(E) STORE <br />ATTIC <br />FAU AA <br />(N) ENTRY <br />8' CLG <br />(N) DINING ROOM <br />(N) KITCHEN <br />8' CLG <br />(N) FRONT PORCH <br />(N) LIVING ROOM <br />(E <br />) <br /> <br />M <br />A <br />S <br />T <br />E <br />R <br /> <br />B <br />A <br />T <br />H <br />CA <br /> 2 <br />4 <br />" <br />X <br />1 <br />8 <br />" <br />. <br />CA <br /> 24 <br />" <br />X <br />1 <br />8 <br />" <br />. <br />W <br />D <br />REFD/W <br />(N) <br />LAUNDRY/PANTRY <br />FOUNDATION PLAN SCHEDULE SYMBOL DESCRIPTIONS <br />SCALE: 1/4"=1'-0"FLOOR AND FOUNDATION PLAN1 <br />INDICATES SHEARWALL TYPE <br />FOR SHEARWALL SCHEDULE <br />SEE 1/S1.21 <br />INDICATES MINIMUM <br />LENGTH OF SHEARWALL <br />SWXX <br />(#'-#") <br />INDICATES HOLDOWN TYPE X <br />INDICATES WOOD POST MARK, <br />SEE POST SCHEDULE <br />C# <br />HDU <br />X <br /># <br />S#.##INDICATES SECTION <br />INDICATES SHEET NUMBER <br />INDICATES DETAIL <br />NUMBER ON THE SHEET <br />S#.## <br /># <br />INDICATES CALLOUT <br />#INDICATES REVISION ON <br />DRAWINGS <br />INDICATES VIEW# <br />S#.## <br />INDICATES LOAD BEARING WALL <br />BW <br />FOUNDATION PLAN NOTES <br />(E <br />) <br />B <br />E <br />A <br />M <br />(E <br />) <br />B <br />E <br />A <br />M <br />(E <br />) <br />B <br />E <br />A <br />M <br />DBL. (N) FLOOR JOIST UNDER <br />KITCHEN ISLAND <br />(N)CRAWL ACCESS <br />PER ARCH. DWG. <br />SEE DETAIL 1/S1.02 <br />(N)4xLEDGER <br />JOIST & HANGER SCHEDULE UNO ON PLAN <br />MARK JOIST SIZE HANGER <br />(N)FJ1 2x6 @16" O.C.- <br />(N)DJ1 2x8 @16" O.C.- <br />POST SCHEDULE UNO ON PLAN <br />MARK POST SIZE <br />(N)C44 4x4 <br />(N)C46 4x6 <br />(N)C66 6x6 <br />(N <br />) <br />4 <br />x <br />6 <br />S1.02 <br />02TYP. <br />(N)FJ1 <br />SCOPE OF WORK <br />(FLOOR AND FOUNDATION PLAN) <br />INDICATES (E) FOUNDATION <br />UNO ON PLAN <br />INDICATES (N) FOUNDATION <br />UNO ON PLAN <br />F <br />D <br />8 <br />A <br />B <br />7 9 <br />C <br />E <br />G <br />H <br />I <br />J <br />K <br />1 2 3 4 5 6 10 11 <br />(N)DJ1 <br />(N) <br />C <br />4 <br />4 <br />(N) <br />C <br />4 <br />6 <br />(N) <br />C <br />4 <br />4 <br />(N) <br />C <br />4 <br />4 <br />(N) <br />C <br />4 <br />4 <br />(N)FJ1 <br />(N)FJ1 <br />(N)FJ1(N)FJ1 <br />(N)2x14 NO.1 <br />UC4A P.T. STRINGER <br />@12" O.C. <br />(N)GH46-8 HANGER <br />(N)DBL.2x4 <br />1 . T HE S E D R A W I NG A R E BAS E D ON T HE B ES T A VAI L A B L E S OU R C ES AN D D O N O T A DD R ES S T H E F IE L D <br />CONDITIONS. THE CONTRACTOR SHALL VER IFY ALL FIELD CONDITIONS AND ALL EXISTING STR UCTURAL <br />E L E M E N T S S P E C I F I E D A S V E R I F I E D I N F I E L D (V .I .F .) P R I O R T O C O M M E N C I N G T H E W O R K . A N Y <br />DISCREPANCIES BETWEEN THESE DRAWINGS AND FIELD CONDITIONS SHALL BE REPORTED TO THE AEOR <br />A N D S E OR . NO WOR K SHALL BE P ER FO RMED IN THE A FF E CTED A R E AS UNTIL T HE DISCR EP ANCI ES AR E <br />RESOLVED. <br />2. NO CUTTING, DRILLING, DEMOLITION OR DESTRUCTIVE WORK ON CONCRETE OR WOOD ELEMENTS SHALL <br />BE PERMITTED UNLESS ALL REINFORCING STEEL INCLUDING PT TENDONS, BEARING WALLS, SHEAR WALLS, <br />BEAMS,AND DIRECTIONS OF JOISTS AND RAFTERS THAT WILL BE AFFECTED ARE POSITIVELY IDENTIFIED. <br />3. CO N T R A C TO R IS SO LE L Y R E SPO N S I B LE F O R PR OT EC TI O N O F A L L S T R U C T U R AL , N O NS T R UC TUR A L , <br />ARCHITECTURAL, FINISHING, ELECTRICAL AND MECHANICAL COMPONENTS WHICH ARE NOT DESIGNATED <br />FOR DEMOLITION OR NEW CONSTRUCTION. ANY DAMAGES CAUSED BY THE CONTRACTOR OR <br />SUBCONTRACTORS SHALL BE REPAIRED BY THE CONTRACTOR AT NO COSTS TO THE ENGINEERS OR OWNER. <br />4. STRUCTURAL DRAWINGS ARE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN <br />CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER <br />DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS <br />INTO THE SHOP DRAWINGS AND FIELD WORK. <br />5. ALL ELEVATIONS, SLOPES, DRAINAGE, DIMENSIONS OF OPENINGS, PENETRATIONS, DEPRESSIONS, AND <br />LAYOUT AND GEOMETRY OF NONSTRUCTURAL ELEMENT SUCH AS BUT NOT LIMITED TO PARTITION, <br />WINDOWS, PLUMBING, ARE NOT INCLUDED IN THE STRUCTURAL ENGINEERING SCOPE OF WORK AND SHALL <br />NOT BE THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER. REFER TO THE DRAWINGS FROM OTHER <br />PROFESSIONS FOR THE INFORMATION MENTIONED ABOVE. <br />6. FOR CONSTRUCTION NOTES AND TYPICAL SYMBOLS DESCRIPTIONS, SEE S0 SERIES SHEETS. <br />7. FOR TYPICAL DETAILS, SEE S1 SERIES SHEETS. DETAILS AND SCHEDULES INDICATED AS 'TYPICAL' MAY <br />NOT BE SPECIFICALLY REFERENCED ON DRAWINGS. DETERMINE WHERE EACH TYPICAL DETAIL OR <br />SCHEDULE APPLIES BEFORE PROCEEDING WITH WORK. <br />8. SEE ARCH./CIVIL DWGS. FOR CONCRETE SLAB ELEVATIONS, DEPRESSIONS, SLOPES, OPENINGS, CURBS, <br />DRAINS, TRENCHES, SLAB EDGE LOCATIONS, ETC., AND FOR WALL OVERALL DIMENSIONS, LOCATIONS OF <br />OPENINGS, ETC., NOT INDICATED ON STRUCTURAL DWGS. <br />9. HOLD-DOWNS& ANCHORS HARDWARE MUST BE SECURED IN PLACE PRIOR TO CALLING FOR FOUNDATION <br />INSPECTION. WET SETTING ANCHORS IS PROHIBITED. <br />10. APPROVED PLATE WASHERS SHALL BE USED FOR HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING. <br />HOLD-DOWNS SHALL BE FINGER TIGHT AND 1/2 WRENCH TURN JUST PRIOR TO COVERING WALL FRAMING. <br />11. STANDING WATER SHALL BE REMOVED FROM THE FOUNDATION EXCAVATIONS PRIOR TO THE CONCRETE <br />PLACING. <br />12. UNO IN ARCH./CIVIL DWGS. SURFACE OUTSIDE THE HOUSE NEEDS TO HAVE 5% SLOPE (UNPAVED <br />SURFACE) & 2% SLOPE (PAVED SURFACE) AWAY FROM THE STRUCTURE. <br />13. ANCHOR BOLTS IN CONTACT WITH PRESSURE TREATED SILL PLATE SHALL BE OF HOT-DIPPED <br />ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. <br />14. MINIMUM EDGE DISTANCE FOR ANCHOR BOLTS SHALL BE 1-3/4". ALL ANCHOR BOLTS SHALL INCLUDE A <br />MINIMUM 0.229"X3"X3" STEEL PLATE WASHER .THE HOLE IN THE PLATE WASHER SHALL BE PERMITTED TO <br />BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 3/16" LARGER THAN THE BOLT DIAMETER AND A SLOT <br />LENGTH NOT TO EXCEED 1-3/4" ,PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE <br />WASHER AND THE NUT .THE PLATE WASHER SHALL EXTEND TO WITHIN 1/2" OF THE EDGE OF THE BOTTOM <br />PLATE ON THE SIDE(S )FOR SHEATHING WITH SHEAR DESIGN VALUES EXCEEDING 400PLF. <br />15. THE FOUNDATION PLAN SHOWS THE GENERAL LAYOUT OF THE FOUNDATION. FOR LOCALIZED SIZE <br />CHANGES AT THE HOLD-DOWNS, REFER TO TYPICAL DETAILS. AT ALL HOLD-DOWN LOCATIONS, <br />FOUNDATION SHALL BE CONSTRUCTED WITH THE DIMENSIONS SPECIFIED IN TABLE FOR HOLD-DOWN <br />ANCHOR SCHEDULE SEE SHEET S1.01. <br />16. ALL WOOD MEMBERS IN CONTACT WITH MASONRY AND CONCRETE SHALL BE PRESSURE-TREATED AND <br />CONFORM TO THE REQUIREMENT OF "AWPA U1" FOR CATEGORY UC4A OR BETTER. <br />17. WOOD AND WOOD BASED MATERIALS USED RAISED FLOOR SYSTEMS INCLUDING JOISTS AND BEAMS <br />SHALL CONFORM TO THE REQUIREMENTS OF "AWPA U1" FOR CATEGORY UC3B OR HIGHER. <br />18. NO HORIZONTAL COLD JOINTS OTHER THAN THE LOCATIONS SHOWN ON THESE DRAWINGS SHALL BE <br />PERMITTED IN FOUNDATION CONSTRUCTION. ALL CONSTRUCTION JOINTS SHALL BE SUBMITTED TO SEOR <br />FOR REVIEW. <br />19. BEARING WALLS SHALL BE SHEATHED ON NOT LESS THAN ONE SIDE OR BRIDGING SHALL BE INSTALLED <br />NOT GREATER THAN 4 FEET APART MEASURED VERTICALLY FROM EITHER END OF THE STUD. 2x BLKG SHALL <br />BE PROVIDED AT PLYWD JOINTS FOR ALL WALLS. <br />20. SPECIAL SOIL CONDITIONS AND PROPERTIES SUCH AS LIQUEFACTION ZONES; ADJACENT TO OR WITHIN <br />AREAS PRONE TO LANDSLIDE, SLOPED LOTS GREATER THAN 1 UNIT VERTICAL UNITS HORIZONTAL ARE NOT <br />INCLUDED IN THIS SCOPE OF WORKS AND NOT CONSIDERED FOR FOUNDATION DESIGN. OWNER SHALL <br />HIRE A SOIL ENGINEER TO VERIFY THESE CONDITIONS AND THEIR EFFECTS ON STRUCTURAL ELEMENTS. <br />21. CONSTRUCTION BELOW THE RAISED FLOOR AND AT CRAWL SPACE INCLUDING LUMBERS AND TIMBERS <br />SHALL BE GRADE 1 OR BETTER , JOISTS & BEAM THAT ARE AT LEAST 18" ABOVE GROUND SHALL BE <br />CATEGORY 3B OR HIGHER AND POSTS, SILL PLATES AND BEAMS AND JOISTS LESS THAN 18" ABOVE THE <br />GROUND SHALL BE CATEGORY 4A OR HIGHER AS SPECIFIED BY AWPA STANDARD U1. <br />22. ALL CRIPPLE WALLS SHALL BE BRACED. <br />23. ALL TOP AND BOTTOM CONTINUAL/ LONGITUDINAL BARS IN STRIP FOUNDATIONS SHALL HAVE <br />STANDARD HOOKS AT THE ENDS. <br />24. ALL TOP AND BOTTOM DISCONTINUED/ LOCAL BARS ( IN BOTH DIRECTIONS ) AT THE PAD/ <br />ISOLATED FOUNDATIONS SHALL HAVE STANDARD HOOKS AT THE ENDS. <br />25. ALL SOG BARS SHALL HAVE STANDARD HOOKS AT THE ENDS. <br />26. FOR DRAINAGE LAYOUT AND REQUIREMENTS, SEE ARCHITECTURAL/CIVIL DRAWINGS. DRAINAGE IS NOT <br />INCLUDED IN STRUCTURAL ENGINEER'S SCOPE OF WORK. <br />27. WHERE THE STEEL COLUMNS ARE EXPOSED TO WEATHER, BASE PLATES AND COLUMNS UP TO 12" ABOVE <br />THE CONCRETE SLAB SHALL BE COATED WITH MIN. 2 COATS OF MACROPOXY 646. <br />28. ALL PERMANENT STEELS IN CONTACT WITH WEATHER SHALL BE PROTECTED FOR CORROSION. <br />29.ALL HANGERS ,COLUMN CAPS ,AND COLUMN BASES ARE MINIMUM REQUIREMENTS ,PRIOR TO ORDER ALL <br />OF THEM SHALL BE CHECKED BY THE CONTRACTOR / FRAMER ANY DISCREPANCY SHALL BE REPORTED TO <br />SEOR. <br />30. FOR ALL BASE PLATES AND STEELS THAT ARE OUTSIDE OR UNDER GROUND, APPLY MIN. 2 COATS OF <br />MACROPOXY 646 WITH MINIMUM 8 MILS THICKNESS. <br />31. THE LOCATION, DIMENSIONS, AND SPECIFIC REQUIREMENTS FOR MECHANICAL EQUIPMENT PADS, <br />INCLUDING HEAT PUMP UNITS AND CONDENSERS, SHALL BE COORDINATED BY THE ARCHITECT WITH THE <br />MECHANICAL ENGINEER, EQUIPMENT MANUFACTURER, AND OTHER RELEVANT DISCIPLINES. FINAL PAD <br />DIMENSIONS, CLEARANCES, ANCHORAGE REQUIREMENTS, AND EQUIPMENT LOADS SHALL BE PROVIDED BY <br />THE MECHANICAL ENGINEER AND/OR MANUFACTURER. <br />32. THE STRUCTURAL ENGINEER OF RECORD (SEOR) SHALL PROVIDE THE STRUCTURAL DESIGN OF THE PAD <br />(E.G., THICKNESS, REINFORCEMENT) BASED SOLELY ON THE MECHANICAL LOADING AND LOCATION <br />INFORMATION FURNISHED BY OTHERS. THE SEOR ASSUMES NO RESPONSIBILITY FOR DETERMINING <br />EQUIPMENT LOCATION, UTILITY COORDINATION, ACCESSIBILITY, SERVICE CLEARANCE, VIBRATION <br />ISOLATION, OR CONFORMANCE WITH MECHANICAL/ELECTRICAL CODES. <br />33. ANY CHANGE IN EQUIPMENT WEIGHT, CONFIGURATION, OR LAYOUT SHALL BE COMMUNICATED TO THE <br />SEOR FOR VERIFICATION OF STRUCTURAL ADEQUACY PRIOR TO CONSTRUCTION. <br />(N)4xLEDGER <br />REVIEW THE PLAN NOTES AND <br />PERFORM FIELD CONDITION <br />ASSESSMENT AND VERIFICATION <br />PRIOR TO COMMENCING THE WORK. <br />LOCATE THE POSITION OF THE <br />REINFORCING STEEL AT THE WORK <br />AREA BY GPR, X-RAY OR OTHER <br />MEANS. SLAB CAN BE POST TENSION <br />WITHOUT ANY STAMP MARK ON IT. <br />EXISTING FOUNDATION SHALL <br />HAVE 12" WIDTH AND 12" DEPTH INTO <br />THE COMPACTED SOIL BELLOW THE <br />ADJACENT GARDE. THE SOIL SHALL <br />HAVE MINIMUM OF 90% COMPACTION <br />DENSITY OR BEING PLACED IN <br />BEDROCK OR NATIVE SOIL. <br />(V.I.F./TYP.) <br />2E <br />S1.01 <br />TYP. <br />TYP. <br />SW1 <br />(30'-7") <br />SW <br />1 <br />(1 <br />6 <br />' <br />- <br />1 <br />0 <br />" <br />) <br />(N) <br />C <br />4 <br />4 <br />(N)HDU2 (N) <br />C <br />4 <br />4 <br />(N) <br />H <br />D <br />U <br />2 <br />(N) <br />C <br />4 <br />4 <br />(N) <br />H <br />D <br />U <br />2 <br />(N) <br />C <br />4 <br />4 <br />(N) <br />H <br />D <br />U <br />2 <br />(N) <br />H <br />D <br />U <br />2 <br />(S <br />W <br />1 <br />) <br />(1 <br />5 <br />' <br />- <br />6 <br />" <br />) <br />(N) <br />C <br />4 <br />4 <br />(N)HDU2 <br />SW <br />1 <br />(1 <br />8 <br />' <br />- <br />1 <br />" <br />) <br />(N) <br />C <br />4 <br />4 <br />3'-0" <br />3' <br />- <br />0 <br />" <br />2'-0" <br />2' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />2'-0" <br />2' <br />- <br />0 <br />" <br />2'-0" <br />2' <br />- <br />0 <br />" <br />(N) 4x6 <br />DROP BEAM <br />(N) 4x6 <br />DROP BEAM(N) 4x6 <br />DROP BEAM <br />(N) 4x6 <br />DROP BEAM <br />(N) <br />H <br />D <br />U <br />2 <br />(N) <br />C <br />4 <br />6 <br />2'- <br />6 <br />" <br />1' <br />- <br />4 <br />" <br />(N <br />) <br />4 <br />x <br />8 <br />1' <br />- <br />6 <br />" <br />(N) <br />C <br />4 <br />4 <br />W/C <br />B <br />S <br />Q <br />4 <br />4 <br />(N)CANT. <br />4x8 <br />(N)HFX 24x14 HARDY PANEL <br />ANCHOR BOLT 1-1/8-HS-RA <br />FOR BOT. CONNECTION <br />SEE DETAIL 10/HFX.01. <br />SEE NOTE A. <br />12 <br />" <br />12 <br />" <br />12"12" <br />(E)12" <br />(V.I.F <br />. <br />) <br />12" <br />(E)12" <br />(V.I.F.) <br />TYP. <br />02 <br />S4.01 <br />TYP. <br />1D <br />S1.01 <br />02 <br />S4.01 <br />(N) <br />C <br />4 <br />4 <br />TYP. <br />S4.01 <br />06 <br />TYP. <br />7 <br />S4.01 <br />(N)THAI222 <br />HANGER <br />W/(N)APT4 <br />09 <br />S4.01 <br />10 <br />S4.01 <br />03 <br />S4.01 <br />11 <br />S4.01 <br />TYP. <br />TYP. <br />TYP. <br />INDICATES JOISTJ# <br />SW <br />1 <br />(8 <br />' <br />- <br />1 <br />1 <br />" <br />) <br />SW <br />1 <br />(5 <br />' <br />- <br />0 <br />" <br />) <br />(N <br />) <br />H <br />D <br />U <br />2 <br />(N) <br />C <br />4 <br />4 <br />(E)BRA <br />C <br />E <br />D <br /> <br />L <br />I <br />N <br />E <br />(E)BRACED LINE <br />(E <br />) <br />B <br />R <br />A <br />C <br />E <br />D <br /> <br />L <br />I <br />N <br />E <br />(E <br />) <br />B <br />R <br />A <br />C <br />E <br />D <br /> <br />L <br />I <br />N <br />E <br />(N) <br />C <br />4 <br />6 <br />(N) <br />H <br />D <br />U <br />2 <br />HFX(2'-0") <br />(N) <br />C <br />4 <br />6 <br />(E) S. <br />O <br />. <br />G <br />. <br />(E <br />) <br />1 <br />2 <br />" <br />(V <br />. <br />I <br />. <br />F <br />. <br />) <br />(E)6" STEM <br />WALL (V.I.F.) <br />(E)FOUNDATION <br />TYP. <br />(E) <br />C <br />4 <br />4 <br />(E) <br />C <br />4 <br />4 <br />(E) <br />C <br />4 <br />4 <br />(E) <br />C <br />4 <br />4 <br />(E) <br />C <br />4 <br />4 <br />(E) <br />C <br />4 <br />4 <br />(E) <br />C <br />4 <br />4 <br />(E) <br />C <br />4 <br />4 <br />(E) <br />C <br />4 <br />4 <br />(E) <br />C <br />4 <br />4 <br />(E) <br />C <br />4 <br />4 <br />(E) <br />C <br />4 <br />4 <br />(E)FJ <br />(E)FJ <br />(N)8" STEM WALL <br />(N)FJ1 <br />(N)FJ1 (N) <br />C <br />4 <br />4 <br />W/A <br />C <br />4 <br />(N) <br />C <br />4 <br />4 <br />W/A <br />C <br />4 <br />(N) <br />C <br />4 <br />4 <br />W/A <br />C <br />4 <br />(N) <br />C <br />4 <br />4 <br />W/A <br />C <br />4 <br />(N) <br />C <br />4 <br />4 <br />W/A <br />C <br />4 <br />(E)FJ <br />(V.I.F. <br /> <br />D <br />I <br />R <br />E <br />C <br />T <br />I <br />O <br />N <br />) <br />(E)BE <br />A <br />M <br />(E)C44 <br />(N)2 #5 EPOXY BARS EXTEND <br />8" INTO (E) FOOTING AND <br />24" INTO (N) FOOTING <br />ALL WOOD MEMBERS (I.E. <br />PLYWOOD, LUMBER, TIMBER, <br />NAILERS. ETC.) SHALL BE <br />PRESSURE TREATED (UC4A) <br />12" <br />(N) <br />C <br />4 <br />6 <br />(N) <br />C <br />4 <br />4 <br />(N) <br />H <br />D <br />U <br />2 <br />(N) <br />C <br />4 <br />4 <br />3'-0" <br />3' <br />- <br />0 <br />" <br />(N) <br />C <br />4 <br />4 <br />(N) <br />C <br />4 <br />4 <br />(N) <br />H <br />D <br />U <br />2 <br />2'-6" <br />2' <br />- <br />6 <br />" <br />(E)6" STEM <br />WALL (V.I.F.) <br />2'-6" <br />2' <br />- <br />6 <br />" <br />(N) <br />H <br />D <br />U <br />2 <br />(N)LUS46 <br />HANGER <br />TYP. <br />12 <br />" <br />12" <br />(N) <br />C <br />4 <br />4 <br />(N) <br />C <br />4 <br />4 <br />(N)C44 <br />W/CBSQ44 <br />NOTE: <br />A.CONTRACTOR SHALL V.I.F NET HEIGHT BELOW EXISTING FLOOR <br />FRAMING AND INFORM THE EOR IN WRITING BEFORE ORDER THE <br />HARDY FRAME. <br />(E <br />) <br />1 <br />2 <br />" <br />(V <br />. <br />I <br />. <br />F <br />. <br />) <br />(N)MSTC40 <br />(TYP.) <br />SW1 <br />(23'-2") <br />(N) <br />C <br />4 <br />6 <br />(N) <br />C <br />4 <br />4 <br />(N) <br />H <br />D <br />U <br />2 <br />S4.01 <br />06 <br />TYP. <br />(N)FJ1 <br />1'-4" <br />1' <br />- <br />4 <br />" <br />(N) <br />C <br />4 <br />4 <br />W/B <br />C <br />4 <br />12 <br />" <br />(N)8" <br />STEM WALL <br />(N) <br />C <br />6 <br />6 <br />W/B <br />C <br />6 <br />0 <br />(N) <br />C <br />6 <br />6 <br />W/B <br />C <br />6 <br />0 <br />(N) <br />C <br />6 <br />6 <br />W/B <br />C <br />6 <br />0 <br />1F <br />S1.01 <br />(N) <br />H <br />D <br />U <br />2 <br />08 <br />S4.01 <br />01 <br />S4.01 <br />05 <br />S4.01 <br />(N)2x6 <br />7'-8" <br />(N) <br />C <br />4 <br />4 <br />(N)8" <br />STEM WALL <br />(E)C44 <br />(N)DJ1 <br />(N)HUC48 <br />HANGER <br />PROJECT <br />CLIENT <br />0'2'4'8'16' <br />SHEET TITLE <br />FOR FIELD VERIFICATION AND <br />CITY PERMIT ONLY <br />922 W PARK LN, <br />SANTA ANA, CA 92706 <br />SAZAN INC. <br />77 Waldorf, Irvine, CA 92612 <br />KAWEHI HOLOMALIA, <br />KEKANI112299@YAHOO.COM <br />S2.01 <br />FLOOR AND <br />FOUNDATION PLAN <br />07/07/2025 <br />EXP. 06-30-2026