2 <br />A-6.0 <br />1 <br />A-6.0 <br />2 <br />A-4.1 <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />10' - 10 1/2"37' - 2 1/2"3' - 11" <br />20' - 11 1/2" <br />5' - 9" <br />4' - 2"5' - 1"5' - 1" <br />6' - 1 3/4"10' - 2"2' - 7"10' - 1 3/8" <br />5' - 3 1/4"23' - 8 7/8" <br />10' - 9 1/2" <br />10' - 2" <br />EXISTING <br />LAUNDRY <br />EXISTING <br />MECH <br />EQ <br />EQ <br />EQ <br />EQ <br />31" <br />15" <br />15" <br />2' - 0"7'-0" HDR. <br />3' - 0" CLR. MIN. <br />1' - 8" <br />1' - 8" <br />BEDROOM 1 <br />104 <br />BEDROOM 2 <br />105 <br />LIVING / <br />KITCHEN <br />102 BATHROOM <br />103 <br />SCM <br />36" REF <br />SS101 <br />102 103 <br />104 <br />106 <br />105 <br />101 102 <br />103 <br />67 <br />6 6 <br />13 <br />13 <br />13 <br />13 <br />14 <br />14 <br />15 <br />24 <br />37 <br />13 <br />EGRESS <br />20 20 <br />EGRESS <br />37 <br />FOR (E) 3.5" CONCRETE <br />SLABS, INSTALL A <br />LAYER OF REDGARD <br />WATERPROOFING <br />FLUID APPLIED VAPOR <br />BARRIER. INSTALL PER <br />MANUFACTURER'S <br />SPECIFICATIONS. ESR <br />1413 <br />33 <br />DW <br />17 18 <br />ADU SETBACK <br />4' - 0" <br />2 <br />A-6.1 <br />2 <br />A-6.1 <br />1 <br />A-6.1 <br />HALL <br />101 <br />1 1/2"3' - 0" <br />WOOD FLOOR <br />8'-0' CLG <br />221.15 SF <br />WINDOW 103 <br />11.00 / 221.15 x 100 = 4.9% VENT <br />17.78 / 221.15 X 100 = 8.0% LIGHT <br />WOOD FLOOR <br />8'-0' CLG <br />100.42 SF <br />WINDOW 101 <br />10.00 / 100.42 x 100 = 9.96% VENT <br />17.78 / 100.42 X 100 = 17.70% LIGHT <br />5' - 0"3 1/2" <br />PROVIDE FURRING WALL <br />AT PLUMBING WALL. NO <br />PENETRATIONS AT 1HR <br />WALL. <br />27 <br />38 <br />36" RANGE <br />3' - 0" <br />107 <br />(E) SHARED WATER <br />HEATER TO BE USED <br />BY NEW ADU <br />(N) <br />CONDESER <br />LOCATION <br />UNIT #E <br />WOOD FLOOR <br />8'-0' CLG <br />100.83 SF <br />WINDOW 102 <br />10.00 / 100.83 x 100 = 9.92% VENT <br />17.78 / 100.83 X 100 = 17.63% LIGHT <br />PROVIDE BACKING FOR <br />FLOOR MOUNTED GRAB <br />BAR <br />FLOOR PLAN KEY NOTES <br />1 PROVIDE 5/8" TYPE "X" GYPSUM BOARD ON ALL GARAGE WALLS, CEILINGS, POSTS, <br />ANS SUPPORTING BEAMS, AND SHALL EXTEND FROM THE GARAGE CONCRETE <br />SLAB TO THE CEILING <br />2 GARAGE DOOR OPENER: PUSH BUTTON SHALL BE PRE-WIRED BEFORE GYPSUM <br />BOARD IS INSTALLED <br />3 PROVIDE 5/8" TYPE "X" GYPSUM BOARD ON WALLS AND CEILINGS IN ENCLOSED <br />USEABLE SPACE UNDER STAIRS <br />4 PROVIDE 5/8" TYPE "X" GYPSUM BOARD ON WALLS AND CEILINGS OF SHAFT <br />ENCLOSURES <br />5 PROVIDE SELF-CLOSING, SELF-LATCHING DEVICE ON 20 MINUTE FIRE RATED <br />DOOR, SEE DOOR SCHEDULE <br />6 PROVIDE STATE FIRE MARSHALL APPROVED SMOKE ALARMS (DETECTORS) AS <br />SHOWN ON THE PLANS AND ACCORDING TO SECTION R314.4 OF THE 2016 CRC. <br />ALARMS SHALL BE HARD WIRED TO SEPARATE CIRCUITS WITH BATTERY BACK UP <br />FOR NEW CONSTRUCTION (907.2.11.4). IN EXISTING SFD, SMOKE DETECTOR MAY <br />BE BATTERY OPERATED. ALARMS SHALL BE LOCATED IN EACH SLEEPING ROOM <br />AND CENTRALLY LOCATED IN CORRIDORS GIVING DIRECT ACCESS TO SLEEPING <br />ROOMS, WHEN SLEEPING ROOMS ARE ON AN UPPER LEVEL, A SMOKE ALARM <br />SHALL BE LOCATED IN CLOSE PROXIMITY TO STAIRWAYS. ALARMS SHALL BE <br />AUDIBLE IN ALL SLEEPING AREAS OF THE DWELLING WHICH THEY SERVE. ALARMS <br />SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE <br />ALARM WILL ACTIVATE ALL OF THE ALARMS. <br />7 PROVIDE STATE MARSHALL APPROVED CARBON MONOXIDE ALARMS AS SHOWN <br />ON PLANS AND ACCORDING TO SECTION R315 OF THE 2016 CRC. ALARMS SHALL <br />BE INSTALLED IN DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL <br />BURNING APPLIANCES ARE INSTALLED, INCLUDING FIRE PLACES, AND IN <br />DWELLING UNITS THAT HAVE ATTACHED GARAGES. CARBON MONOXIDE ALARMS <br />SHELL BE PROVIDED IN EACH SLEEPING AREA, IMMEDIATELY OUTSIDE EACH <br />SLEEPING AREA, AND ON EVERY LEVEL OF THE DWELLING UNIT, INCLUDING <br />BASEMENTS. CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED IN SUCH <br />A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATED ALL OF THE <br />ALARMS IN THE DWELLING. <br />8 30" X 30" ROOF ACCESS, SEE DETAILS <br />9 30" X 30" ATTIC ACCESS, SEE DETAILS <br />10 30" X 54" ACCESS WITH PULL-DOWN LADDER, SEE DETAILS <br />11 CRAWLSPACE (UNDERFLOOR) ACCESS, SEE DETAILS <br />12 6" X 14" UNDERFLOOR SCREENED VENT, SEE EXTERIOR ELEVATIONS AND DETAILS <br />13 BUILT-IN CABINETRY <br />14 CLOSET MILLWORK, SEE DETAILS FOR LEVELS A, B, C, D, AND E <br />15 BATHROOM EXHAUST FAN CAPABLE OF PROVIDING THE MINIMUM RATE OF 50 <br />CUBIC FEET PER MINUTE (12 L/s) CONTINOUS VENTILATION PER SECTION R303.3 <br />OF THE 2016 CRC. VENTILATION AIR FROM THE SPACE SHALL BE EXHAUSTED <br />FDIRECTLY TO THE OUTSIDE. EXHAUST FANS SHALL BE ENERGY STAR <br />COMPLIANT. ROOMS CONTAINING BATHTUBS, SHOWER, SPAS, AND SIMILAR <br />BATHINGFIXTURES, SHALL BE MECHANICALLY VENTILATED. SEPARATE <br />MECHANICAL PERMIT MAY BE REQUIRED (1203.5.2.1) <br />16 PRE-FABRICATED FIREPLACE UNIT: FMI MODEL DVF42NH, DIRECT VENT SEALED <br />COMBUSTION (PFS REPROT #09-95: ANSI STANDARD Z21 .50b-2009 VENTED GAS <br />FIREPLACES CSA 2.22b-2009), WITH HERRINGBONE BRICK PATTERNS. PROVIDE <br />UNIT CONTROLS AND VENTING SYSTEMS PER MANUFACTURER'S <br />RECOMMENDATIONS, SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION <br />17 WASHER: PROVIDE RECESSED HOT AND COLD WATER DRAIN STAND PIPE, AND <br />FLOOR DRAIN UNDER WASHER <br />18 DRYER: PROVIDE WEATHER HOOD VENT WITH DAMPER TO OUTSIDE AIR AT ROOF. <br />VENT DUCT SHALL BE MINIMUM 4" DIAMETER, SMOOTH GALVANIZED METAL, <br />LIMITED TO TWO (2) 14'-0" LEGNTH WITH TWO (2) ELBOWS, SEE MECHANICAL <br />PLANS. <br />19 GAS METER. PROVIDE EARTHQUAKE VALVE <br />20 MINI SPLIT REGISTER WITH ELECTRIC HEAT PUMP. SEE TITLE 24. HEATER <br />CAPABLE OF MAINTAINING A MIN. ROOM TEMPERATURE OF 68 DEG. F AT A POINT 3 <br />FEET ABV THE FLOOR AND 2 FEET FROM EXTERIOR WALLS IN ALL HABITABLE <br />ROOMS AT TE DESIGN TEMPERATURE <br />21 ELECTRICAL PANEL, SEE ELECTRICAL PLANS <br />22 PHONE PANEL: ALL LINES TO BE HOME RUNS, SEE ELECTRICAL AND A/V PLAN <br />23 HEAT PUMP WATER HEATER. PROVIDE REQUIRED STRAPPING AND ENCLOSURE. <br />SEE TITLE 24 DRAWINGS <br />24 TUB / SHOWER WITH TILE / STONE FINISH ON WALLS, FLOORS TO CELING, SEE <br />INTERIOR ELEVATIONS <br />25 SHOWER WITH TILE / STONE FINISH ON WALLS, FLOOR TO CEILING, SEE INTERIOR <br />ELEVATIONS <br />26 FRAMELESS 3/8" THICK TEMPERED GLASS ENCLOSURE WITH SET-IN GLAZING <br />CHANNEL, SEE SPECS AND INTERIOR ELEVATIONS <br />27 SOAP / SHAMPOO NICHE, SEE DETAILS AND INTERIOR ELEVATIONS FOR SIZE <br />28 WATER METER LOCATION <br />29 PROVIDE 30" X 24" WATER CLOSET CLEARANCE <br />30 "INSTA-HOT" DISPENSER AND WATER FILTRATION SYSTEM, VERIFY WITH OWNER <br />31 PROVIDE PURIFIED COLD WATER SUPPLY LINE TO ICE-MAKER WITH RECESSED <br />SHUT-OFF VALVE, VERIFY WITH MANUFACTURER <br />32 LINE OF EXHAUST HOOD ABOVE, VENT TO OUTSIDE AIR WITH REMOTE EXHAUST <br />FANS. VERIFY VENTING REQUIREMENTS WITH MECHNAICAL PLANS AND <br />MANUFACTURER'S RECOMMENDATIONS. <br />33 HOSE BIBB IN RECESSED ENCLOSURE, FIXTURE TO MATCH WINDOW / DOOR <br />FRAME FINISH. COORDINATE LOCATIONS WITH ARCHITECT. <br />36 ELECTRIC VEHICLE CHARGING STATION, INSTALL CONDUIT AND ELECTRICAL <br />PANEL CAPACITY FOR FUTURE VEHICLE PARKING FOR AT LEAST 3% OF THE <br />TOTAL PARKING SPACES BUT NOT LESS THAN ONE. (4.107 AND A5.106.5.33) <br />34 GUARDRAIL, 42" ABOVE FINISH FLOOR <br />35 HANDRAIL, 34-38" ABOVE FINISH FLOOR WITH 1 1/2" - 2" HANDGRIP, SEE DETAILS <br />SHEET A-9.5 <br />FLOOR PLAN NOTES <br />VERIFY ALL EXISTING CONDITIONS AND INFORM ARCHITECT OF ANY <br />DISCREPANCIES <br />B <br />DO NOT SCALE DRAWINGS, REFER TO DIMENSIONS AS SHOWNA <br />CONTACT ARCHITECT FOR ANY MISSING DIMENSIONS OR INFORMATIONC <br />ALL DIMENSIONS ARE TO FACE OF CONCRETE OR FACE OF STUDD <br />INSULATION: PROVIDE R-19 MIN. AT ALL EXTERIOR WALLS, INCLUDING GARAGE. <br />PROVIDE R-30 INSULATION IN ATTIC SPACES. PROVIDE R-19 INSULATION AT ALL <br />INTERIOR WALLS. PROVIDE R-30 INSULATION AT ALL FLOOR FRAMING. SEE TITLE <br />24 FOR ADDITIONAL REQUIREMENTS. PROVIDE INSULATION AROUND PLUMBING <br />PIPES AND HVAC DUCTS, SEE MECHANICAL AND PLUMBING PLANS FOR <br />ADDITIONAL REQUIREMENTS <br />E <br />ROUGH CARPENTER TO COORDINATE FRAMING LAYOUT WITH LIGHTING, <br />PLUMBING, AND MECHANICAL PLANS AND INFORM ARCHITECT OF ANY <br />DISCREPANCIES. ALL REQUIRED FURRING, SOFFITS, VOLUME CEILINGS AND <br />NON-STRUCTURAL FRAMING SHALL BE INCLUDED IN BID <br />F <br />REFER TO REFLECTED CEILING PLANS, BUILDING SECTIONS, AND INTERIOR <br />ELEVATIONS FOR VOLUME CEILINGS <br />G <br />ALL EXTERIOR STUDS SHALL BE 2X4 FRAMING OR MULTIPLE ROWS OF 2X4 <br />FRAMING UNLESS OTHERWISE NOTED. ALL INTERIOR WALLS SHALL BE 2X4 <br />FRAMING UNLESS OTHERWISE NOTED. SPACING AND SPECIFICATION ARE PER <br />STRUCTURAL <br />H <br />PROVIDE DRAFT STOPS AS REQUIRED IN SECTION R302.11 OF THE 2011 CRC OR <br />CURRENT BUILDING CODE: ENCLOSED SPACES IN STUD WALLS, PARTITIONS, AND <br />FURRED WALLS SHALL HAVE FIRE STOPS AT TOP AND BOTTOM AND AT MID POINT <br />IN WALLS MORE THAN 10 FEET HIGH <br />I <br />CONTRACTOR SHALL PROVIDE ALL REQUIRED SHIMMING SO THAT FINISH FLOOR <br />MATERIALS ALIGN AT THE SAME ELEVATION, UNLESS OTHERWISE NOTED <br />J <br />CONTRACTOR SHALL COORDINATE ALL WINDOW AND DOOR ROUGH OPENING <br />WITH MANUFACTURER <br />K <br />PROVIDE EMERGENCY EGRESS FROM SLEEPING ROOMS ACCORDING TO SECTION <br />R310 OF THE 2011 CRC: MINIMUM 24 INCHES CLEAR HEIGHT, 20 INCHES CLEAR <br />WIDTH; 5.7 SQ. FT. MINIMUM AREA (5.0 SQ. FT. AT GRADE), AND 44 INCHES <br />MAXIMUM TO WINDOW SILL <br />L <br />FOR ALL PLUMBING FIXTURES AND APPLIANCES VERIFY WITH INTERIOR DESIGNERM <br />PROVIDE A WHOLE-HOUSE VENTILATION SYSTEM FOR ALL HABITABLE SPACESN <br />37 PROVIDE A SMOOTH LANDING WITH A MINIMUM 36" LENGTH IN THE DIRECTION OF <br />TRAVEL. <br />38 MEDICINE CABINET <br />NEW WALL <br />EXISTING WALL <br />WALL LEGEND <br />DEMO WALL <br />1-HR RATED WALL <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />COLUMNS TO REMAINBEAM TO REMAIN <br />GARAGE GARAGE GARAGE <br />COLUMN TO REMAIN <br />COLUMN TO REMAIN <br />REMOVE EXISTING WALL <br />LOCATION OF (N) WINDOW <br />REMOVE (E) GARAGE DOORS <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />10' - 10 1/2"37' - 2 1/2"3' - 11" <br />2 <br />A-6.1 <br />1 <br />A-6.1 <br />1 <br />A-6.1 <br />DEMOLITION FLOOR PLAN NOTES <br />CONTRACTOR NOTE: BIDDERS, BEFORE SUBMITTING PROPOSALS, SHALL VISIT <br />AND CAREFULLY EXAMINE THE AREA AFFECTED BY THIS WORK TO FAMILIARIZE <br />THEMSELVES WITH THE EXISTING CONDITIONS AND THE DIFFICULTIES THAT WILL <br />ATTEND THE EXECUTION OF THIS WORK. SUBMISSIONS OF A PROPOSAL WILL BE <br />CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE IN AN <br />ATTEMPT TO OBSERVE DIFFICULTIES THAT WOULD BE ENCOUNTERED ONLY IF <br />SUCH AN EXAMINATION HAD BEEN MADE. <br />A. <br />CONTRACTOR SHALL TAKE ALL PRECAUTIONS DURING DEMOLITION WORK SO AS <br />NOT TO CAUSE ANY DAMAGE TO EXISTING WORK TO REMAIN. <br />B. <br />BEFORE ANY REMOVAL WORK IS STARTED, ELECTRICAL CONTRACTOR SHALL <br />VERIFY THAT SERVICE HAS BEEN CUT TO THAT AREA EXCEPT AS NOTED BELOW. <br />C. <br />CONTRACTOR SHALL COORDINATE HIS WORK WITH THAT OF THE MECHANICAL <br />AND ELECTRICAL SUBCONTRACTORS BEFORE WORK IS STARTED. <br />D. <br />REMOVE EXISTING PARTITIONS WHERE INDICATED ON PLANS AND REQUIRED BY <br />FIELD CONDITIONS. <br />E. <br />CONTRACTOR NOTE THAT ALL EXISTING CARPETING, BASE AND ALL OTHER <br />FINISHES ARE TO BE REMOVED, UNLESS OTHERWISE NOTED. <br />F. <br />CONTRACTOR SHALL REMOVE ALL DEBRIS FROM BUILDING AND SITE AT THE END <br />OF EACH DAY. ACCUMULATION OF RUBBISH SHALL NOT BE PERMITTED. <br />SPRINKLE ALL WORK TO LAY OUT SO IT DOES NOT BECOME A NUISANCE TO <br />OTHERS AT WORK. <br />G. <br />AT NO TIME SHOULD THE CONTRACTOR ALLOW THE DEMOLITION WORK OR <br />STORAGE OF DEBRIS TO CAUSE INTERFERENCE WITH ANY REQUIRED MEANS OF <br />EGRESS OR CAUSE A HAZARDOUS CONDITION. <br />H. <br />CONTRACTOR NOTE THAT ACOUSTIC TILE AND GRID CEILING IS TO REMAIN <br />UNLESS OTHERWISE NOTED OR REQUIRED BY THESE DRAWINGS, CEILING LIGHTS, <br />DIFFUSERS, TILE, ETC., WILL BE MODIFIED OR ALTERED AS REQUIRED BY NEW <br />FLOOR PLAN. ALL COMPONENTS IN ACCEPTABLE CONDITION ARE TO BE REUSED. <br />I. <br />MAINTAIN AT ALL TIMES THE EMERGENCY LIGHTING THROUGHOUT THE BUILDING <br />DURING DEMOLITION WORK, AS WELL AS RECONSTRUCTION WORK. PROVIDE ALL <br />NECESSARY TEMPORARY LIGHTING, PARTITIONS, DUST COVERS, DROP COVERS, <br />ETC. <br />J. <br />COORDINATE WITH CONTRACTOR FOR DEMOLITION WORK AND DISCONNECT LINE <br />END OF CONDUCTORS WHICH ARE DIRECTLY AFFECTED BY DEMOLITION OR <br />WHICH FEED EQUIPMENT. <br />K. <br />CUT, CAP AND FLUSH ALL ABANDONED STUBS, AND PROVIDE REQUIRED <br />PATCHING. PROVIDE ABANDONED OUTLETS WITH BLANK COVER. <br />L. <br />PROVIDE BOX AND SPLICE WIRES WHERE IT IS REQUIRED TO MAINTAIN <br />CONTINUITY OF CIRCUITS OR REMOVE WIRING AND SPLICE WIRE AT NEAREST <br />ACTIVE BOX FROM OUTLETS WHICH HAVE BEEN TERMINATED. <br />M. <br />COORDINATE ALL WORK, SCHEDULING, ETC., WITH BUILDING OWNER.N. <br />INCLUDE IN BID ALL DEMOLITION WORK AS REQUIRED TO COMPLETE ALL NEW <br />WORK AS DELINEATED BY ARCHITECTURAL AND ENGINEERING DRAWINGS <br />WHETHER SHOWN ON DRAWINGS OR NOT I.E.; COORDINATION OF ALL <br />SUBCONTRACTORS WORK, ELECTRICAL, PLUMBING, HVAC, CUTTING, PATCHING, <br />ETC. <br />O. <br />CUT ALL EXISTING WALLS/PARTITIONS ETC., AS REQUIRED FOR ALL ELECTRICAL, <br />HVAC, PLUMBING AND SPRINKLER WORK, INCLUDE ALL PATCHING AND <br />REFINISHING. <br />P. <br />CONTRACTOR IS TO REMOVE ALL MISCELLANEOUS ATTACHED ITEMS, BOARDS, <br />SCREENS, TV'S, ETC. VERIFY DISPOSITION WITH OWNER AND EITHER RETURN TO <br />OWNER OR DISCARD. <br />Q. <br />WHERE ATHC IS TO BE REMOVED: REMOVE ANY AND ALL GYPSUM BOARD <br />CEILINGS, AND/ OR SOFFITS, IN THE AFFECTED AREA. <br />R. <br />ANY STAIR REMOVAL NOTES APPLY TO ENTIRE STAIR TO ITS TERMINATION, I.E.; AT <br />ROOF OR AT SECOND FLOOR), WHETHER STATED OR NOT. <br />S. <br />ALL EXISTING POKE-THROUGH FITTINGS NOT BEING REUSED SHALL BE REMOVED. <br />ALL CORE-DRILLED HOLES SHALL BE PATCHED. INSTALL NEW METAL DECKING, <br />TACK WELD TO UNDERSIDE OF EXISTING DECK, POUR CONCRETE TO FINISH <br />FLUSH WITH EXISTING CONCRETE FLOOR SLAB. <br />T. <br />SEE CONSTRUCTION PLANS & FURNITURE/ELECTRICAL PLANS FOR NEW <br />POKE-THROUGH LOCATIONS. <br />U. <br />PRIOR TO THE START OF DEMOLITION, CONTRACTOR SHALL VERIFY THAT ALL <br />WALLS AND SOFFITS TO BE REMOVED DO NOT CONTAIN PLUMBING OR <br />ELECTRICAL RUNS FROM ABOVE OR BELOW. <br />V. <br />TYPE X 5/8" <br />GYPSUM <br />BOARD. <br />MIN 1-HR EXTERIOR WALL <br />PER 15-1.3 AND 15-1.15 FROM <br />TABLE 721.1(2) OF CRC <br />BATT <br />INSULATION <br />2X4 #1 DF STUD <br />SHEATHING <br />PER <br />STRUCTURAL <br />MIN. 7/8" CEMENT <br />STUCCO <br />PLASTER. <br />2" × 4" wood studs 16" on center with 7/8" cement plaster <br />(measured from the face of studs) on the exterior surface with <br />interior surface treatment as required for interior wood stud <br />partitions in this table. Plaster mix 1:4 for scratch coat and 1:5 <br />for brown coat, by volume, cement to sand. <br />2" × 4" wood studs at 16" with double top plates, single <br />bottom plate; interior and exterior sides covered with 5/8" <br />Type X gypsum wallboard and sheathing, respectively, 4' <br />wide, applied horizontally or vertically with vertical joints over <br />studs, and fastened with 21/4" Type S drywall screws, spaced <br />12" on center. Cavity to be filled with 31/2" mineral wool <br />insulation. <br />A <br /> <br />R <br /> <br /> <br />C <br /> <br /> <br />H <br /> <br /> <br />I <br /> <br /> <br />T <br /> <br /> <br />E <br /> <br /> <br />C <br /> <br /> <br />T <br /> <br /> <br />U <br /> <br /> <br />R <br /> <br /> <br />E <br />D <br /> <br />I <br /> <br /> <br />A <br /> <br /> <br />L <br /> <br /> <br />E <br /> <br /> <br />C <br /> <br /> <br />T <br /> <br /> <br />I <br /> <br /> <br />C <br /> <br />80 <br />1 <br /> <br />S <br />O <br />U <br />T <br />H <br /> <br />H <br />O <br />P <br />E <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />, <br /> <br /> <br />S <br />U <br />I <br />T <br />E <br /> <br />9 <br />1 <br />7 <br /> <br />| <br /> <br />L <br />O <br />S <br /> <br />A <br />N <br />G <br />E <br />L <br />E <br />S <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />0 <br />0 <br />1 <br />7 <br />62 <br />6 <br />. <br />3 <br />7 <br />5 <br />. <br />2 <br />8 <br />7 <br />3 <br /> <br />| <br /> <br />W <br />W <br />W <br />. <br />D <br />I <br />A <br />L <br />E <br />C <br />T <br />I <br />C <br />A <br />R <br />C <br />H <br />. <br />C <br />O <br />M <br /> <br />| <br /> <br /> <br />D <br />I <br />A <br />L <br />E <br />C <br />T <br />I <br />C <br />A <br />R <br />C <br />H <br />@ <br />G <br />M <br />A <br />I <br />L <br />. <br />C <br />O <br />M <br />REVISIONS <br />ISSUE DATE: <br />PROJECT #: <br />DRAWN BY: <br />CHECKED BY: <br />SCALE: <br />DIGITAL STAMP <br />As indicated <br />PI <br />N <br />E <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br /> <br />A <br />D <br />U <br /> <br />2 <br />A-4.0 <br />PLANS <br />Checker <br />2401.00 <br />VF <br />03.12.2025 <br />PERMIT SET <br />42 <br />3 <br /> <br />E <br /> <br />P <br />I <br />N <br />E <br /> <br />S <br />T <br /> <br />& <br /> <br />4 <br />2 <br />3 <br /> <br />P <br />I <br />N <br />E <br /> <br />S <br />T <br />. <br /> <br />UN <br />I <br />T <br /> <br /># <br />E <br /> <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />SCALE: 3/8" = 1'-0"PROPOSED FLOOR PLAN 1 <br />SCALE: 3/8" = 1'-0"DEMOLITION PLAN 2 <br />SCALE: 1 1/2" = 1'-0"1HR WALL 3 <br />AGE IN PLACE NOTES: <br />DOORBELL BUTTONS - DOORBELL BUTTONS OR CONTROLS, <br />WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES (1219.2 MM) <br />ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE <br />TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE <br />DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES <br />ARE REQUIRED TO BE INSTALLED ABOVE 48 INCHES (1219.2 <br />MM) MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A <br />STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE <br />PROVIDED AT A HEIGHT NOT EXCEEDING 48 INCHES (1219.2 <br />MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM <br />THE TOP OF THE DOORBELL BUTTON OR CONTROL. (CRC <br />R327.1.4) <br />AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE <br />PROVIDED WITH REINFORCEMENT INSTALLED IN <br />ACCORDANCE WITH CRC R327.1. <br />• REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER <br />CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING <br />AGENCY. <br />• REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH (51 <br />MM BY 203 MM) NOMINAL LUMBER. [11/2 INCH BY 71/4 INCH (38 <br />MM BY 184 MM) ACTUAL DIMENSION] OR OTHER <br />CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND <br />LOAD CAPACITY. REINFORCEMENT SHALL BE LOCATED <br />BETWEEN 32 INCHES (812.8 MM) AND 391/4 INCHES (997 MM) <br />ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL <br />FRAMING. <br />• WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON <br />BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND <br />THE BACK WALL. <br />• SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE <br />WALL FRAMING IS PROVIDED. <br />• BATHTUB AND COMBINATION BATHTUB/SHOWER <br />REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF <br />THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK <br />WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE <br />PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN <br />6 INCHES (152.4 MM) ABOVE THE BATHTUB RIM. <br />O EXCEPTIONS: <br />O WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO <br />A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, <br />THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION <br />OF FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE <br />GRAB BAR REINFORCEMENTS APPROVED BY THE ENFORCING <br />AGENCY. <br />O REINFORCEMENT SHALL NOT BE REQUIRED IN WALL <br />FRAMING FOR PRE-FABRICATED SHOWER ENCLOSURES AND <br />BATHTUB WALL PANELS WITH INTEGRAL FACTORY- INSTALLED <br />GRAB BARS OR WHEN FACTORY-INSTALLED REINFORCEMENT <br />FOR GRAB BARS IS PROVIDED. <br />O SHOWER ENCLOSURES THAT DO NOT PERMIT <br />INSTALLATION OF REINFORCEMENT AND/OR GRAB BARS <br />SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR <br />INSTALLATION OF FLOOR-MOUNTED GRAB BARS OR AN <br />ALTERNATE METHOD IS APPROVED BY THE ENFORCING <br />AGENCY. <br />O BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE <br />WALL PANELS DO NOT PERMIT THE INSTALLATION OF <br />REINFORCEMENT SHALL BE PERMITTED, PROVIDED <br />REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED <br />GRAB BARS ADJACENT TO THE BATHTUB OR AN ALTERNATE <br />METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />O REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED <br />FOR BATHTUBS AND WATER CLOSETS INSTALLED ON <br />CONCRETE SLAB FLOORS.