My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
407 & 419 E 1st St - Plan
PBA
>
Building
>
ProjectDox
>
F
>
First St
>
407 E First St
>
407 & 419 E 1st St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:21 AM
Creation date
2/13/2026 5:00:29 AM
Metadata
Fields
Template:
Plan
Permit Number
20186557
20186558
101124531
101124532
Full Address
407 E First St
419 E First St
Street Number
419
Street Direction
E
Street Name
First
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Testing <br />1. Coefficient of Friction <br />2. Wind Tunnel <br />3. UL 2703 <br />4. Component Testing (Bay and Clamp) <br />Setbacks <br />For the wind tunnel recommendations in U-Builder to apply, the following setbacks should be observed/followed for <br />U-Builder wind design: <br />1. Modules should be placed a minimum of 3.00 ft from the edge of the building in any direction. <br />2. If the array is located near an obstruction that is 3.50 ft wide and 3.50 ft high or larger, the nearest <br />module of the array must be located a distance from the obstruction that is greater than or equal to the height of the obstruction. Exception: When <br />using ASCE 7-16/ASCE 7-22 Building Code and using the obstruction feature in the module editor to accurately model the size and location of <br />obstruction. <br />3. Installations within the setbacks listed above require site specific engineering. <br />4. The setbacks above are for wind and seismic. Fire access isles, mechanical equipment etc., may require larger setbacks than listed above. <br />Site Specific Engineering <br />Conditions listed below are beyond the current capabilities of U-Builder. Site specific engineering is required. <br />1. Building assumptions and design parameters outside of U-Builder assumptions <br />2. Wind tunnel testing reduction factors are not permitted by the Authority Having Jurisdiction (AHJ) <br />3. Seismic designs that fall outside SEAOC PV1-2012/ASCE 7-16/ASCE 7-22 SECTION 13.6.12 recommendations (>3% roof slope, or AHJ’s that <br />require shake table testing or non-linear site-specific response history analysis) <br />4. Signed and sealed site-specific calculations, layouts, and drawings <br />5. Building that is not enclosed and categorized as open structures, carport or others <br />Notes: <br />• Please contact EngineeringServices@unirac.com for more information. <br />Page 32 of 32 <br />Page 52
The URL can be used to link to this page
Your browser does not support the video tag.