EP <br />BATH 2 <br />BATH 1 <br />W/D <br />WH <br />BEDROOM 1 <br />BEDROOM 2 <br />BEDROOM 3 <br />DINING <br />LIVING <br />REF. <br />KITCHEN <br />PANTRY <br />-1.5"2% <br />Min. <br />CRH <br />WP <br /> GFCI <br />DW <br />W <br />D <br />30 AMP <br />WH <br />RF <br />OD <br />CT <br />V <br />CTV <br />+48" GFCIAFCI <br />+48" GFCI <br />+30" AFCI/GFCI <br />S <br />CT <br />V <br />240V- GFCI <br />240V- GFCI <br />GFCI <br />AFCIAFCI <br />AFCI AFCI <br />AFCI <br />AFCI AFCI <br />AFCI AFCI <br />AFCI <br />AFCI <br />AFCI <br />AFCI <br />AFCI AFCI <br />AFCI <br />AFCI <br />AFCI <br />AFCI <br />AFCI <br />AFCI <br />AFCI <br />+30" AFCI/GFCI <br />+4 <br />8 <br />" <br /> <br />G <br />F <br />C <br />I <br />+4 <br />8 <br />" <br /> <br />G <br />F <br />C <br />I <br />+4 <br />8 <br />" <br /> <br />G <br />F <br />C <br />I <br />+6 <br />5 <br />" <br /> <br />G <br />F <br />C <br />I <br />24 <br />0 <br />V <br /> <br />- <br />G <br />F <br />C <br />I <br /> G <br />F <br />C <br />I <br />+4 <br />8 <br />" <br /> <br />G <br />F <br />C <br />I <br /> G <br />F <br />C <br />I <br />WP <br /> GFCI <br />24 <br />0 <br />V <br /> <br />- <br />G <br />F <br />C <br />I <br />+48" AFCI <br />DOORBELL <br />1.1 <br />TYP. <br />1.2 <br />1.3 TYP. <br />1.4 <br />1.6 <br />1.6 <br />1.6 <br />1.8 1.7 <br />U9 <br />1.2 <br />U5 <br />U4 <br />U8 <br />M2M3 <br />1.51.6 1.9 <br />BATH 2 <br />BATH 1 <br />W/D <br />WH <br />BEDROOM 1 <br />BEDROOM 2 <br />BEDROOM 3 <br />DINING <br />LIVING <br />REF. <br />KITCHEN <br />PANTRY <br />-1.5"2% <br />Min. <br />D <br />S <br />D <br />S <br />S/C <br />S <br />D <br />D <br />2DS/C <br />P <br />EF <br />59 <br /> <br />C <br />F <br />M <br />EF <br />DVS <br />280 CFM <br />59 <br /> <br />C <br />F <br />M <br />VS <br />VS <br />2D <br />D <br />10 <br />0 <br /> <br />C <br />F <br />M <br />D <br />VS <br />10'-0" CLG. <br />10'-0" CLG. <br />10'-0" CLG. <br />10'-0" CLG. <br />9'-0" CLG. <br />9'-0" CLG. <br />IDID <br />ID <br />ID <br />V <br />Min. 3'-0" <br />2.2 <br />TYP. <br />2.4 <br />2.6 <br />2.5 <br />2.1 <br />2.3 <br />2.7 <br />2.7 <br />2.7 <br />GENERAL NOTES KEY NOTES <br />DRYER MACHINE - PROVIDE GAS LINE, <br />EXHAUST TO OUTSIDE <br />ELECTRICAL SYMBOLS <br />CTV FLUSH WALL MOUNTED CABLE TV RECEPTACLE <br />FLUSH WALL MOUNTED DUPLEX RECEPTACLE <br />FLUSH WALL MOUNTED DEDICATED DUPLEX <br />RECEPTACLE <br />FLUSH WALL MOUNTED HALF-SWITCHED DUPLEX <br />RECEPTACLE <br />GROUND FAULT CIRCUIT INTERRUPTERGFCI <br />WATERPROOF RECEPTACLEWP <br />EQUIPMENT LIST <br />RF <br />H <br />CR <br />DW <br />RANGE HOOD WITH A MIN. EXHAUST RATE <br />OF 280 CFM - VENTED TO OUTSIDE <br />COOKING RANGE - PROVIDE GAS LINE <br />CONNECTION <br />DISHWASHER - PROVIDE WATER LINE <br />REFRIGERATOR - PROVIDE WATER LINE <br />D <br />W WASHER MACHINE - PROVIDE DRAIN LINE <br />WATER SHUT-OFF VALVE <br />EP MAIN SERVICE ELECTRICAL PANEL - MAINTAIN <br />36" CLEAR FROM FACE OF PANEL TO ANY <br />OBSTRUCTION. PROVIDE UFER GROUNDING <br />SYSTEM PER CEC 250.52(A)(3). <br />W/H WALL MOUNTED TANK-LESS WATER HEATER <br />SHALL BE STRAPPED TO STRUCTURE WITH 1 <br />1 2" x 16GA STRAPS AT TOP & BOTTOM WITH <br />3 8"DIA. x 3" LONG LAG BOLT - PROVIDE DRAIN <br />LINE WATER SHUT-OFF VALVE, POWER, GAS <br />LINE & EXHAUST TO OUTSIDE. MOUNTED @ <br />44" A.F.F. MIN. <br />OUTDOOR RECEPTACLES SHALL BE LISTED AS WEATHER <br />RESISTANT PER SECTION 406.9(B) (1). <br />1.1 <br />PROVIDE A MINIMUM OF (1) 20-AMP CIRCUIT FOR <br />BATHROOM OUTLET. SUCH CIRCUIT SHALL HAVE NO <br />OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN <br />ONE BATHROOM, PER CEC 210-52(C) (1). <br />1.2 <br />PROVIDE A MINIMUM OF (2) 20-AMP SMALL APPLIANCE <br />CIRCUITS FOR KITCHEN COUNTER TOPS. SUCH CIRCUIT <br />SHALL HAVE NO OTHER OUTLETS. LOAD SHALL BE <br />BALANCED, PER CEC 210-52(B) (2). <br />1.3 <br />FOR ELECTRIC CLOTHES DRYER READY: A DEDICATED <br />240 V BRANCH CIRCUIT WIRING SHALL BE INSTALLED <br />WITHIN 3 FEET FROM THE CLOTHES DRYER LOCATION <br />AND ACCESSIBLE WITH NO OBSTRUCTION. THE THE <br />BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT <br />30AMPS MIN. THE BLANK COVER SHALL BE IDENTIFIED AS <br />"240V READY". THERE SHALL BE A RESERVED DOUBLE <br />POLE CIRCUIT BREAKER SPACE IN THE ELECTRICAL <br />PANEL LABELED "240V DRYER". <br />1.4 <br />PROVIDE A MINIMUM 4" DIA. MOISTER EXHAUST DUCT TO <br />OUTSIDE, EQUIPPED WITH BACK-DRAFT DAMPER. <br />MOISTER EXHAUST DUCTS SHALL NOT EXCEED A TOTAL <br />COMBINED HORIZONTAL AND VERTICAL LENGHT OF 14'. <br />DUCT LENGTH IS LIMITED OR REQUIRED BY THE <br />MANUFACTUER'S INSTALLATION INSTRUCTIONS AND <br />APPROVED BY THE BUILDING OFFICIAL. <br />2.1 <br />PROVIDE GARBAGE DISPOSAL WITH SWITCH <br />CONTROL ON SIDE OF KITCHEN CABINET. <br />1.5 <br />SWITCH FOR HALF-SWITCHED OUTLET.1.6 <br />PROVIDE A DEDICATED GAS LINE FROM THE GAS METER <br />TO THE WATER HEATER. <br />1.7 <br />PROVIDE UFER GROUNDING SYSTEM PER CEC <br />250.52(A)(3). <br />1.8 <br />ELECTRIC VEHICLEEV <br />GROUNDING PANEL <br />EXHAUST AIR TO OUTSIDE THROUGH ROOF. <br />U9 <br />ID INDOOR UNIT AC. <br />CEILING MOUNTED SMOKE DETECTOR IN EACH BEDROOM & <br />KITCHEN. INSTALL +30" FROM AIR INTAKE SMOKE DETECTOR <br />SYSTEM SHALL DIRECT WIRED, INTERCONNECTED, SHALL BE <br />EQUIPPED WITH A BATTERY BACKUP AND SHALL EMIT A <br />SIGNAL WHEN THE BATTERY IS LOW. <br />A.AMINIMUM OF 20 FT. FROM PERMENANT COOKING <br />EQUIPMENT (OR 10 FT WITH PHOTO ELECTRIC TYPE.) <br />B.A MINIMUM OF 3 FT. FROM BATHROOM. <br />COMBINATION SMOKE/CARBON MONOXIDE ALARM, CEILING <br />MOUNTED, HARD WIRED AND W/ BATTERY BACK UP.ICC <br />APPROVED <br />LIGHTING/MECH. SYMBOLS <br />EF CEILING MOUNTED EXHAUST FAN/FLUORESCENT LIGHT <br />COMBINATION. EXHAUST FAN TO EXTERIOR WITH AIRFLOW <br />RATED ON TITLE 24. EXHAUST FAN MUST BE CONTROLLED <br />BY A HUMIDISTAT WHICH SHALL BE CAPABLE ADJUSTMENT <br />BETWEEN RELATIVE HUMINITY RANGE OF 50% TO 80%. <br />S/C <br />S <br />U4 NEW DUAL ELECTRICAL PANEL 200 AMP. <br />U7 NEW GAS METER LOCATION. <br />U5 NEW 100AMP ELECTRICAL SUB-PANEL FOR ADU. <br />U6 NEW 100AMP ELECTRICAL SUB-PANEL FOR MAIN <br />HOUSE. <br />U8 SOLAR PANEL SYSTEM. <br />4-ZONE MULTI-SPLIT SYSTEM AC. HEAT PUMP HEATING <br />FACILITY ON PLAN TO MATCH WITH T-24 ENERGY CALCULATION: <br />M2 <br />FAN COIL AND HEAT PUMP <br />FC-12(CARRIER - 40MAHBQ12XA3) OR EQUAL <br />FC-09(CARRIER - 40MAHBQ09XA3) OR EQUAL <br />HP-30(CARRIER - 38MGHBQ30DA3) <br />OR EQUAL <br />MECHANICAL: <br />HP30 <br />FC-12 (LIVING) <br />FC-09 (BEDROOM 1) <br />FC-09 (BEDROOM 2) <br />FC-09 (BEDROOM 3) <br />HEAT PUMP WATER HEATERS - T24: <br />Rheem PRO H40 T2 RH310BM (40 gal, JA13) <br />OR EQUAL <br />2.2 <br />PROVIDE ACCESS DOOR . OPENING SHALL BE 30" x 30" <br />WITH 30" MIN. HEADROOM. ACCESS DOOR MUST BE <br />WITHIN 20 FEET OF FURNACE UNIT AND SHOULD HAVE A <br />CONTINUOUS SOLID PATHWAY 24" MIN. WIDE. PROVIDE A <br />SWITCH CONTROLLED LIGHT. [CMC. 304.4.1] <br />M3 PAD SUPPORTING CONDENSER SHALL BE A MINIMUM OF 3" <br />ABOVE THE GRADE (1105.2 CMC) <br />2.6 FAU LOCATED IN ATTIC WITH VERTICAL DUCT VENT TO <br />EXTERIOR. PROVIDE POWER CONNECTION . PROVIDE <br />MINIMUM 36"x36" CLEAR WORKING SPACE PLATFORM IN <br />FRONT OF UNIT. <br />D / VS LIGHT SWITCH. ALL SWITCHES TO HAVE <br />DIMMER CONTROL, EXCEPT, UTILITY & <br />LAUNDRY RM, GARAGE <br />D INDICATE DIMMER <br />OS INDICATE OCCUPANCY SENSOR <br />VS INDICATE VACANCY SENSOR <br />P INDICATE PHOTOCELL SENSOR <br />RECESSED LED DOWN LIGHT FIXTURE <br />WALL MOUNTED EXTERIOR LED LIGHT FIXTURE, HIGH <br />EFFICACY AND CONTROL BY MOTION SENSOR AND <br />PHOTO-SENSOR COMBINATIONS. <br />WALL MOUNTED BATHROOM LED LIGHT FIXTURE <br />1.CONTRACTOR SHALL COMPLY WITH APPLICABLE LOCAL, <br />STATE AND FEDERAL CODES AND REGULATIONS PERTAINING <br />TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL <br />PROTECTION. <br />2.ALL ELECTRICAL OUTLET TO BE MOUNTED @ 15" A.F.F. <br />3.ALL APPLIANCES TO BE "ENERGY STAR". <br />4.PROVIDE TAMPER-RESISTANT FOR ALL 15 & 20 AMP <br />RECEPTACLES IN NEW CONSTRUCTION AREA PER CEC 406.12. <br />5.PROVIDE IN KITCHEN LOCAL EXHAUST SYSTEM VENTED TO <br />OUTDOOR WITH RATE = 100 CFM. <br />6. AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED: <br /> A. ESS READY INTERCONNECTION EQUIPMENT WITH A MINIMUM <br />BACKED-UP CAPACITY OF 60 AMPS AND A MINIMUM OF FOUR <br />ESS-SUPPLIED BRANCH CIRCUITS; OR <br /> B. A DEDICATED RACEWAY FROM THE MAIN SERVICE TO A <br />PANELBOARD (SUBPANEL) THAT SUPPLIES THE BRANCH <br />CIRCUITS IN SEC. 150.0(S)(2). ALL BRANCH CIRCUITS ARE <br />PERMITTED TO BE SUPPLIED BY THE MAIN SERVICE PANEL PRIOR <br />TO THE INSTALLATION OF AN ESS. THE TRADE SIZE OF THE <br />RACEWAY SHALL BE NOT LESS THAN 1 INCH. THE PANELBOARD <br />THAT SUPPLIES THE BRANCH CIRCUITS (SUBPANEL) MUST BE <br />LABELED “SUBPANEL SHALL INCLUDE ALL BACKED-UP LOAD <br />CIRCUITS.” <br />7.A MINIMUM OF FOUR BRANCH CIRCUITS SHALL BE IDENTIFIED <br />AND HAVE THEIR SOURCE OF SUPPLY COLLOCATED AT A SINGLE <br />PANELBOARD SUITABLE TO BE SUPPLIED BY THE ESS. AT LEAST <br />ONE CIRCUIT SHALL SUPPLY THE REFRIGERATOR, ONE LIGHTING <br />CIRCUIT SHALL BE LOCATED NEAR THE PRIMARY EGRESS AND AT <br />LEAST ONE CIRCUIT SHALL SUPPLY A SLEEPING ROOM <br />RECEPTACLE OUTLET. <br />8.THE MAIN PANELBOARD SHALL HAVE A MINIMUM BUSBAR RATING <br />OF 225 AMPS. <br />9.SUFFICIENT SPACE SHALL BE RESERVED TO ALLOW FUTURE <br />INSTALLATION OF A SYSTEM ISOLATION EQUIPMENT/ TRANSFER <br />SWITCH WITHIN 3 FT. OF THE MAIN PANELBOARD. RACEWAYS <br />SHALL BE INSTALLED BETWEEN THE PANELBOARD AND THE <br />SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCH LOCATION <br />TO ALLOW THE CONNECTION OF BACKUP POWER SOURCE. <br />10.ALL INSTALLED LUMINARIES MUST BE HIGH EFFICACY IN <br />ACCORDANCE WITH TABLE 150.0-A. <br />11.EXHAUST FANS MUST BE SWITCHED SEPARATELY FROM <br />LIGHTING SYSTEMS. <br />12.IN BATHROOMS, GARAGE, LAUNDRY ROOM, UTILITY ROOM, AT <br />LEAST ONE LUMINARIES IN EACH OF THESE SPACES MUST BE <br />CONTROLLED BY VACANCY SENSOR. <br />13.OUTDOOR LIGHTING PERMANENTLY MOUNTED TO BUILDING <br />MUST MEET THE REQUIREMENT IN ITEM 150.0(k)3Ai (ON AND <br />OFF SWITCH) AND THE REQUIREMENTS IN EITHER ITEM <br />150.0(k)3Aii (PHOTOCELL AND MOTION SENSOR) OR ITEM <br />150.0(k)3Aiii (PHOTO CONTROL AND AUTOMATIC TIME SWITCH <br />CONTROL, ASTRONOMICAL TIME CLOCK, OR EMCS). <br />14.SHOW COMPLIANCE WITH THE FOLLOWING LIGHTING MEASURES: <br />[150.0(K) / 160.5(A)] <br />A.KITCHENS. ALL INSTALLED WATTAGE OF LUMINARIES IN <br />KITCHENS SHALL BE HIGH EFFICACY. <br />B.LIGHTING IN BATHROOMS, GARAGES, LAUNDRY ROOMS, <br />WALK-IN CLOSETS AND UTILITY ROOMS. ALL LUMINAIRES <br />SHALL BE HIGH EFFICACY AND SHALL BE CONTROLLED BY <br />AN OCCUPANCY OR VACANCY SENSOR. <br />C.HABITABLE SPACES. ALL LUMINAIRES SHALL BE HIGH <br />EFFICACY AND SHALL BE CONTROLLED BY A VACANCY/ <br />OCCUPANCY SENSOR OR DIMMER. <br />D.OUTDOOR LIGHTING. ALL LUMINAIRES MOUNTED TO THE <br />BUILDING OR TO OTHER BUILDINGS ON THE SAME LOT <br />SHALL BE HIGH EFFICACY LUMINAIRES AND SHALL BE <br />CONTROLLED BY A PHOTOCONTROL/MOTION SENSOR <br />COMBINATION (WITH OVERRIDE). SEE 150(K)3 FOR <br />REQUIREMENTS. <br />2.4 <br />EXHAUST FAN MUST BE SWITCHED SEPARATELY FROM <br />LIGHTING SYSTEMS. AND SHOULD BE HUMIDISTAT FAN. <br />2.5 SMOKE ALARMS WITHIN 20 FEET OF COOK TOP SHALL BE <br />IONIZED OR PHOTOELECTRIC TYPE. <br />2.3 PROVIDE KITCHEN LOCAL EXHAUST SYSTEM <br />VENTED TO OUTDOOR WITH RATE = 280 CFM . <br />2.7 PROVIDE LIGHTING WITH CONTROLLED BY VACANCY <br />SENSOR IN BATHROOM, W.I. CLOSET, GARAGES, <br />LAUNDRY ROOMS, AND UTILITY ROOMS. <br />2.7 PROVIDE LIGHTING WITH CONTROLLED BY VACANCY <br />SENSOR IN BATHROOM, W.I. CLOSET, GARAGES, <br />LAUNDRY ROOMS, AND UTILITY ROOMS. <br />1.9 FOR ELECTRIC COOKTOP: A DEDICATED 240 V BRANCH <br />CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FEET <br />FROM THE COOKTOP LOCATION AND ACCESSIBLE WITH <br />NO OBSTRUCTION. THE THE BRANCH CIRCUIT <br />CONDUCTORS SHALL BE RATED AT 30AMPS MIN. THE <br />BLANK COVER SHALL BE INDENTIFIED AS "240V READY". <br />THERE SHALL BE A RESERVED DOUBLE POLE CIRCUIT <br />BREAKER SPACE IN THE ELECTRICAL PANEL LABELED <br />"240V COOKTOP". <br />DELTA DATE DESCRIPTION <br />MA <br />I <br />N <br /> <br />H <br />O <br />U <br />S <br />E <br /> <br />R <br />E <br />M <br />O <br />D <br />E <br />L <br /> <br />- <br /> <br />B <br />A <br />T <br />H <br />R <br />O <br />O <br />M <br />40 <br />1 <br /> <br />W <br /> <br />J <br />o <br />n <br />q <br />u <br />i <br />l <br /> <br />R <br />d <br />, S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />NE <br />W <br /> <br />A <br />D <br />U <br />40 <br />1 <br /> <br />W <br /> <br />J <br />o <br />n <br />q <br />u <br />i <br />l <br /> <br />R <br />d <br />, <br />U <br />n <br />i <br />t <br /> <br />2 <br />, <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />3/19/2025 <br />DATE SIGNED: <br />ARCHITECTURE <br />1 PROPOSED ADU - ELECTRICAL & EQUIPMENT <br />1/4"=1'-0" <br />2 PROPOSED ADU - REFLECTED CEILING PLAN <br />1/4"=1'-0"