provide additional backing for <br />fold away grab bar. <br />verify requirement with <br />selected manufacturer <br />grab bar reinforcement for <br />water closets <br />back wall side wall <br />2' <br />- <br />8 <br />" <br /> <br />M <br />A <br />X <br />2' <br />- <br />8 <br />" <br /> <br />M <br />A <br />X <br />3' <br />- <br />2 <br />" <br /> <br />M <br />I <br />N <br />3'-6" MIN1'-0" <br />MAX <br />3' <br />- <br />2 <br />" <br /> <br />M <br />I <br />N <br />2'-2" <br />MIN <br />3'-4" MIN <br />1' <br />- <br />4 <br />" <br />MI <br />N <br />1'-4" <br />32 <br />" <br />full width at all <br />shower stall walls <br />side wallback wall grab bar reinforcement <br />for shower <br />39 <br /> <br />1 <br />/ <br />4 <br />" <br />full width at all <br />shower stall walls <br />Reinforcement shall not be <br />less than 2x8 or other <br />construction material providing <br />equal height and load capacity <br />AGING-IN-PLACE/FALL PREVENTION FEATURES <br />AGING-IN-PLACE/FALL PREVENTION NOTES: <br />A. Reinforcement for Grab Bars. [R327.1.1] At least one bathroom on <br />the entry level shall be provided with reinforcement installed in <br />accordance with this section. Where there is no bathroom on the <br />entry level, at least one bathroom on the 2nd, or 3rd floor of the <br />dwelling shall comply. <br />1. Reinforcement shall be solid lumber or other construction <br /> material approved by the enforcing agency. <br /> 2. Reinforcement shall not be less than 2 by 8 inch nominal <br />lumber (1-1/2" x 7 1/4" actual dimension) or other construction <br />material providing equal height and load capacity. <br />Reinforcement shall be located between 32" and 39 1/4" <br />above finish floor, flush with the wall framing. <br /> 3. Water closet reinforcement shall be installed on both side <br />walls of the fixture, or one side wall and the back side wall. <br /> 4. Shower reinforcement shall be continuous where wall framing is <br />provided. <br /> 5. Bathtub and combination bathtub/shower reinforcement shall be <br />continuous on each end of the bathtub and the back wall. <br />Additionally, back wall reinforcement for a lower grab bar shall be <br />provided with the bottom edge located no more than 6" above the <br />bathtub rim. <br /> 6. Where the water closet is not placed adjacent to a side wall <br />capable of accommodating a grab bar, the bathroom shall have <br />provisions for installation of floor-mounted, foldaway or similar <br />alternate grab bar reinforcement approved by the enforcing <br />agency. <br />B. Documents for Grab Bar Reinforcement. [R327.1.1.] Information <br />and/or drawings identifying the location of grab bar reinforcement <br />shall be placed in the operation & maintenance manual in <br />accordance with the California Green Building Standards Code, <br />Chapter 4, Division 4.4 <br />C. Electrical Receptacle Outlet, Switch & Control Height [R327.1.2] <br />Electrical Receptacle outlets, switches and controls (including <br />controls for heating, ventilation and air conditioning) intended to be <br />used by occupants shall be located no more than 48" measured from <br />the top of the outlet box and not less than 15" measured from the <br />bottom of the outlet box above the finish floor. <br />D. Interior Doors [R327.1.3] Effective July 1, 2024, at least one <br />bathroom and one bedroom on the entry level shall provide a <br />doorway with a net clear opening of not less than 32", measured with <br />the door positioned at an angle of 90 degrees from the closed <br />position; or in the case of 2- or 3- story single family dwelling, on the <br />2nd and 3rd floor of the dwelling if a bathroom and bedroom is not <br />located on the entry level. <br />E. Doorbell Buttons [R327.1.4] Doorbell buttons or controls, when <br />installed, shall not exceed 48" above exterior floor or landing, <br />measured from the top of the doorbell button assembly. Where <br />doorbell buttons integrated with other features are required to be <br />installed above 48" measured from the exterior floor or landing, a <br />standard doorbell button or control shall also be provided at a height <br />not exceeding 48" above exterior floor or landing, measured from the <br />top of doorbell button or control. <br />NOTE:SIZES ARE TAKEN FROM DATA SUPPLIED BY WINDOW MANUFACTURERS. HOWEVER THESE ARE GENERAL DIMENSIONS. IT IS <br />THE OWNER"S RESPONSIBILITY TO VERIFY THAT THE ACTUAL WINDOWS INSTALLED MEET THE MINIMUM EGRESS REQUIREMENTS. <br />STANDARD 6'-8" HEADER HEIGHT <br />Casement <br />Single/Double Hung <br />Slider <br />44 <br />" <br /> <br />M <br />A <br />X <br />. <br />TO <br /> <br />A <br />C <br />T <br />U <br />A <br />L <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br />44 <br />" <br /> <br />M <br />A <br />X <br />. <br />TO <br /> <br />A <br />C <br />T <br />U <br />A <br />L <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br />34-1/8" CLEAR <br />20" CLEAR <br />41 <br />" <br /> <br />C <br />L <br />E <br />A <br />R <br />24 <br />" <br /> <br />C <br />L <br />E <br />A <br />R <br />44 <br />" <br /> <br />M <br />A <br />X <br />. <br />FLOOR LEVEL <br />EMERGENCY ESCAPE/ EXIT WINDOW FOR BEDROOMS <br />ICC-P104.4.1 REQUIREMENTS <br />1.20" MIN. CLEAR WIDTH <br />2.24" MIN. CLEAR HEIGHT <br />3.5.7 SF MIN. OPENABLE AREA (EXCEPT FOR GROUND FLOOR) <br />4.5.0 SF MIN. OPENABLE AREA FOR GROUND FLOOR <br />MIN.WINDOW SIZE <br />FOR 24" CLEAR HEIGHT <br />(USING 5.7 S.F. REQ'T.) <br />MIN. WINDOW SIZE <br />FOR 20" CLEAR WIDTH <br />(USING 5.7 S.F. REQ'T.) <br />OPENABLE <br />AREA <br />OPENABLE <br />AREA <br />THE FOLLOWING WINDOW SIZES WILL BE THE MINIMUM ALLOWED FOR EGRESS <br />UNLESS MANUFACTURERS DATA IS PROVIDED PROVIDING ACCEPTABLE OPENING SIZE <br />FOR 5.7 SF (REQ'D. UNLESS FOR GROUND FLOOR) <br />NEW FOR 2022 CBC - FOR 5.0 SF {GROUND FLOOR) <br />Single Casement Single/Double Hung Slider <br />Single Casement Single/Double Hung Slider <br />Double Casement <br />Double Casement <br />NOTE:OTHER WINDOW TYPES SUCH AS AWNING. BAY W/ FIXED CENTER & SINGLE / FIXED COMBO ARE NOT <br />ALLOWED AS AN EGRESS WINDOW UNLESS MFR'S DATA IS PROVIDED SHOWING ACCEPTABLE OPENING SIZE. <br />2'-4" x 4'-0" <br />2'-6" x 3'-6" <br />4'-8" x 4'-0" <br />5'-0" x 3'-6" <br />3'-0" x 5'-0" <br />3'-0" x 5'-6" <br />2'-6" x 6'-2" <br />2'-8" x 5'-8" <br />2'-4" x 6'-8" <br />4'-0" x 4'-0" <br />5'-0" x 3'-6" <br />6'-0" x 3'-0" <br />2'-4" x 3'-6" <br />2'-6" x 3'-0" <br />4'-8" x 3'-6" <br />5'-0" x 3'-0" <br />2'-9" x 5'-0" <br />3'-0" x 4'-8" <br />2'-6" x 5'-0" <br />2'-8" x 5'-2" <br />2'-4" x 5'-8" <br />4'-0" x 3'-6" <br />5'-0" x 3'-0" <br />6'-0" x 3'-0" <br />FLOOR LEVEL <br />MINIMUM WINDOW SIZE (NEW AND REPLACE WINDOW) <br />EVERY HABITABLE ROOM MUST BE PROVIDED WITH NATURAL LIGHT BY MEANS <br />OF EXTERIOR OPENINGS WITH AN AREA NOT LESS THAN 8 PERCENT OF THE <br />FLOOR AREA OF SUCH ROOMS. EVERY HABITABLE ROOM MUST BE PROVIDED <br />WITH NATURAL VENTILATION BY MEANS OF EXTERIOR OPENINGS WITH AN AREA <br />NOT LESS THAN 4 PERCENT OF THE FLOOR AREA OF SUCH ROOMS. <br />ICC-228.4.9 REQUIREMENTS <br />doorbell <br />48 <br />" <br /> <br />M <br />A <br />X <br />1' <br />- <br />3 <br />" <br />MI <br />N <br />4' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />electrical receptacle outlet, switch & <br />control mounting heights <br />push button <br />doorbell heights <br />finish floor <br />1 DETAIL A - 1HR FIRE RATED EXTERIOR WALL AND EAVE PROJECTION <br />NTS <br />DELTA DATE DESCRIPTION <br />MA <br />I <br />N <br /> <br />H <br />O <br />U <br />S <br />E <br /> <br />R <br />E <br />M <br />O <br />D <br />E <br />L <br /> <br />- <br /> <br />B <br />A <br />T <br />H <br />R <br />O <br />O <br />M <br />40 <br />1 <br /> <br />W <br /> <br />J <br />o <br />n <br />q <br />u <br />i <br />l <br /> <br />R <br />d <br />, S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />NE <br />W <br /> <br />A <br />D <br />U <br />40 <br />1 <br /> <br />W <br /> <br />J <br />o <br />n <br />q <br />u <br />i <br />l <br /> <br />R <br />d <br />, <br />U <br />n <br />i <br />t <br /> <br />2 <br />, <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />3/19/2025 <br />DATE SIGNED: <br />ARCHITECTURE <br />3 DETAIL C - AGING-IN-PLACE/FALL PREVENTION FEATURES <br />NTS2DETAIL B - HABITABLE ROOM AND EGRESS WINDOW <br />NTS