Laserfiche WebLink
Job No: <br />Drawn by: <br />Sheet: <br />Date: <br />Scale: <br />DA <br />T <br />E <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />10 <br />4 <br />9 <br />2 <br /> <br />T <br />R <br />A <br />S <br />K <br /> <br />A <br />V <br />E <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />B <br />Ga <br />r <br />d <br />e <br />n <br /> <br />G <br />r <br />o <br />v <br />e <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />8 <br />4 <br />3 <br />Ph <br />o <br />n <br />e <br />: <br /> <br />( <br />7 <br />1 <br />4 <br />) <br />4 <br />1 <br />7 <br />- <br />1 <br />8 <br />3 <br />9 <br /> <br />- <br /> <br />( <br />6 <br />5 <br />7 <br />) <br />7 <br />2 <br />0 <br />- <br />8 <br />5 <br />5 <br />5 <br />Em <br />a <br />i <br />l <br />: <br /> <br />a <br />r <br />t <br />. <br />d <br />e <br />s <br />i <br />g <br />n <br />. <br />g <br />r <br />o <br />u <br />p <br />2 <br />0 <br />2 <br />2 <br />@ <br />g <br />m <br />a <br />i <br />l <br />. <br />c <br />o <br />m <br />De <br />s <br />i <br />g <br />n <br />EISTING FOOR PAN <br />PROPOSED FOOR PAN <br />A-1 <br />1 <br />A <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br /> <br />F <br />O <br />R <br />TE <br />N <br />A <br />N <br />T <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br />ON <br />S <br />E <br />N <br /> <br />H <br />E <br />A <br />D <br />S <br />P <br />A <br /> <br />A <br />N <br />D <br /> <br />W <br />E <br />L <br />L <br />N <br />E <br />S <br />S <br />040225 <br />33 <br />7 <br />6 <br /> <br />S <br /> <br />B <br />r <br />i <br />s <br />t <br />o <br />l <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />1/4" = 1'-0"PROPOSED FLOOR PLAN21/4" = 1'-0"EXISTING / DEMOLITION FLOOR PLAN <br />(E) ENTRANCE <br />60x60 CLR. <br />(E)FIXED WINDOW, <br />TEMP TO BE REMAIN <br />(E)FIXED WINDOW, <br />TEMP TO BE REMAIN <br />(E)FIXED WINDOW, <br />TEMP TO BE REMAIN <br />(E) BUILDING COLUMN <br />(E) BUILDING COLUMN <br />(E) EXIT <br />60x60 CLR. <br />(E) <br />ALL GENDER <br />RESTROOM <br />TO BE REMAIN <br />EXISTING WALLS AND DOOR TO BE REMOVED <br />(E) <br />(E) <br />(E) <br />(E) ENTRANCE <br />(E)FIXED WINDOW, <br />TEMP TO BE REMAIN <br />(E)FIXED WINDOW, <br />TEMP TO BE REMAIN <br />(E)FIXED WINDOW, <br />TEMP TO BE REMAIN <br />(E) BUILDING COLUMN <br />(E <br />) <br /> <br />B <br />U <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />C <br />O <br />L <br />U <br />M <br />N <br /> <br />NOT AN EXIT DOOR <br />60x60 CLR. <br />(E) <br />ALL GENDER <br />RESTROOM <br />(E) <br />(E) <br />(E) <br />1960 SF <br />CHANGING ROOM <br />DRY HAIR ROOM <br />30X36 <br />REF. <br />STACK. <br />W/D 6 <br />57 <br />9 <br />FACIAL ROOM <br />GLASS WALL, TEMP. <br />BREAKROOM <br />CU <br />S <br />T <br />O <br />M <br />E <br />R <br /> <br />L <br />O <br />C <br />K <br />E <br />R <br />RE <br />C <br />E <br />P <br />T <br />I <br />O <br />N <br />34 <br />" <br /> <br />m <br />a <br />x <br />. <br /> <br />A <br />F <br />F <br />4 <br />WAITING AREA <br />10 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />8 <br />HAIR SPA ROOM #1 <br />HAIR SPA ROOM # 2 <br />2 <br />STORAGE/LAUNDRY <br />2 2 <br />2 2 <br />1 <br />1 <br />GLASS WALL, TEMP. <br />Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort.” <br />CBC Section 11B-404.2.9: <br /> “Maximum effort to operate doors shall not exceed 5 pounds for exterior doors and interior doors, such pull or push effort being applied at right angles to hinged doors and at the center <br />place of sliding or folding doors. Compensating devices or automatic door operators may be utilized to meet the above standards. When fire doors are required, the maximum effort to <br />operate the door may be increased to the minimum allowable by the appropriate administrative authority, not to exceed 15 pounds. <br />Tactile exit signs shall be required at the following locations: <br />-Each grade-level exterior exit door shall be identified by a tactile exit with the word “EXIT.” <br />-Each exit door that leads directly to a grade-level exterior exit by means of an exit enclosure, or an exit passageway, shall be identified by a tactile exit sign with the words “EXIT <br />ROUTE.” <br />-Each exit access door from an interior room or area to a corridor or hallway, which is required to have a visual exit sign, shall be identified by a tactile exit sign with the words “EXIT <br />ROUTE.” <br />-Each exit door through a horizontal exit shall be identified by a sign with the words “TO EXIT.” <br />CBC 11B-303. <br />There shall be a floor or landing on each side of a <br />door.the floor or landing shall be not more than ½” lower than the threshold of the doorway <br />It is the project designer’s/property owner’s responsibility to show compliance on the drawings with all applicable Federal and State Accessibility Standards. <br />2406.3 Identification of Safety Glazing <br />Except as indicated in Section 2406.3.1, each pane of safety glazing installed in hazardous locations shall be identified by a manufacturer's designation specifying who applied the <br />designation, the manufacturer or installer and the safety glazing standard with which it complies, as well as the information specified in Section 2403.1. The designation shall be acid <br />etched, sand blasted, ceramic fired, laser etched, embossed or of a type that once applied, cannot be removed without being destroyed. A label meeting the requirements of this section <br />shall be permitted in lieu of the manufacturer's designation. <br />Exceptions: <br />For other than tempered glass, manufacturer's designations are not required, provided that the building official approves the use of a certificate, affidavit or other evidence confirming <br />compliance with this code. <br />Tempered spandrel glass is permitted to be identified by the manufacturer with a removable paper designation. <br />2406.3.1 Multipane Assemblies <br />Multipane glazed assemblies having individual panes not exceeding 1 square foot (0.09 m2) in exposed areas shall have one pane or more in the assembly marked as indicated in Section <br />2406.3. Other panes in the assembly shall be marked "CPSC 16 CFR Part 1201" or "ANSI Z97.1," as appropriate. <br />2406.3.1 Multipane Assemblies <br />1. ALL EXIT DOORS SHALL PROVIDE FOR DISABLED ACCESS PER CBC 11B-404.2.7. <br />2. HAND-ACTIVATED DOOR OPENING HARDWARE MUST BE MOUNTED BETWEEN 34 AND 48 INCHES ABOVE FINISH FLOOR. <br />3. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT IN ACCORDANCE WITH THE CBC <br />4. DOOR HARDWARE SHALL BE OPERABLE WITH A SINGLE EFFORT WITHOUT REQUIRING THE ABILITY TO GRASP THE HARDWARE (LEVER OR PUSH TYPE IS <br />ACCEPTABLE) PER CBC 11B-404.2.7. <br />5. PER CBC 11B-4-4.2.9, THE MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5LBS. FOR EXTERIOR AND INTERIOR DOORS, SUCH PULL OR PUSH EFFORT <br />BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLACE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR <br />OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. <br />6. PANIC HARDWARE SHALL COMPLY WITH CBC 1008.1.9. <br />7. THE LOWER 10" OF THE DOOR SHALL BE A SMOOTH AND PLANE SURFACE. (NO RECESS OR TRAP). <br />8. MODIFY WIDTH OF DOOR STOP TO ACCOMMODATE TOTAL DOOR THICKNESS, INCLUDING VENEER. <br />9. MINIMUM STRIKE EDGE DISTANCES SHALL BE PROVIDED PER CBC 1004.4.9.2.3a. <br />10. THE SWEEP OF A DOOR CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO <br />A POINT 3" FROM THE LATCH AS MEASURED FROM THE LEADING EDGE OF THE DOOR. <br />11. LEVEL LANDINGS SHALL BE PROVIDED ON EACH SIDE OF DOORS. LANDINGS SHALL BE AT THE SAME ELEVATION ON EACH SIDE OF THE DOOR. LANDINGS SHALL <br />HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE DOOR AND A LENGTH MEASURED IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 44 INCHES PER CBC <br />1008.1.5, 1008.1.6. <br />12. THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL EXTEND 24" PAST THE STRIKE EDGE OF THE EXTERIOR DOORS AND 18" FOR <br />INTERIOR DOORS <br />13. THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2" LOWER THAN THE THRESHOLD OF THE DOORWAY. BEVEL 1:2 MAX. SLOPE, WHERE THRESHOLD EXCEEDS <br />1/4" IN HEIGHT. <br />14. EXTERIOR LEVEL LANDING MAY SLOPE UP TO 1/4" PER FOOT IN ANY DIRECTION FOR SURFACE DRAINAGE. SEE CIVIL DRAWINGS FOR GRADE ELEVATIONS. <br />15. WHERE NOTED AND/OR REQUIRED, A DURABLE SIGN WITH LETTERING ON A CONTRASTING BACKGROUND WILL BE PLACED OVER EXIT DOORS STATING "THIS <br />DOOR TO REMAIN UNLOCKED WHEN THE BUILDING IS OCCUPIED" PER CBC 1010.1.9.3. <br />16. PROVIDE INTERNATIONAL SYMBOL OF ACCESSIBILITY AT ALL ACCESSIBLE ENTRANCES PER CBC 11B-216.1 & 11B-703.1 <br />17. PROVIDE CBC COMPLIANT WALL AND DOOR SIGNAGE AT ALL ACCESSIBLE RESTROOMS. <br />18. VALID EXIT DOOR HARDWARE- WHERE PANIC IS NOT REQUIRED. <br />-SELF-RELEASING DOOR HARDWARE WITH INTERCONNECTED SINGLE LOCKING HARDWARE: SINGLE DEADBOLT PROTECTION WITH A SINGLE MOTION EXITING <br />(CO-ACTIVATING) WHEN THE LEVER IS TURNED. THE DEADBOLT RETRACTS WHEN THE INTERIOR LEVER TURNED. <br />-SELF-RELEASING DOOR HARDWARE: THE OUTSIDE LEVER IS LOCKED AND UNLOCKED BY THE KEY FROM HE EXTERIOR. THE INSIDE LEVER IS ALWAYS <br />UNLOCKED AND PROVIDES A SINGLE MOTION EXITING WHEN THE INTERIOR LEVER IS TURNED. <br />#Q.SIZE DESCRIPTION DOOR FINISH FRAME M.F.LOCATION REMARKSTHICK <br />1 3/4" <br />DOOR HARDWARE/ HINGERS <br />LOCK, SEALS, DOOR BOTTOM& THRESHOLD <br />1 <br />EXISTING AND NEW DOOR SCHEDULE <br />a/ ALL DOOR HARDWARE TO MEET ADA CODE,b/ VERIFY EXISTING DOORS TO MEET CODE18" HIGH STAINLESS KICKPLATES ON BOTH SIDES <br />MAIN EXIT DOOR SHALL PROVIDED WITH A DURABLE SIGN OF ONE (1") LETTERS ON <br />CONTRASTING BACKGROUND INDICATING (THERE DOOR TO REMAIN UNLOCKED WHEN <br />THIS SPACE IS OCCUPIED) . PUSH - PULL <br />EXISTING FRONT <br />EXTERIOR 1 DOOR FRONT ENTRANCEEXISTING <br />3 <br />101A <br />101B <br />SURFACE CLOSER-P404 1 <br />EDA-695-LCN <br />KICK PLATE-8400 10"x2" <br />LDW-613-IVES <br />LOCK GUARD-LG1-600 <br />1 3/4" <br />101C <br />1 EXISTING <br />EXISTING <br />SELF CLOSING3'-0" x8'-0" <br />INTERIOR WD. SOLID CORE PAINT SEMI GLOSS WD.SELF-CLOSING <br />LEVER TYPE <br />1101D 1 3/4"EXSTINGPAINT SEMI GLOSSREAR DOOR <br />EXISTING <br />SELF CLOSINGWD.REAR DOOR <br />3'-0" x6'-8" <br />3'-0" x6'-8" <br />Shall be openable from the inside <br />without the use of a key or any <br />special knowledge or effort. <br />PAINT SEMI GLOSS WD. <br />3 <br />1 3/4"NEWINTERIOR WD. SOLID CORE PAINT SEMI GLOSS WD.3'-0" x6'-8" <br />60x60 CLR. <br />INTERIOR WALL @ SLAB <br />TYPICAL NON-BEARING <br />NON BEARING WALL DETAIL 34 <br />36X48 CLR. <br />36 <br />X <br />4 <br />8 <br /> <br />C <br />L <br />R <br />. <br />36X48 CLR. <br />36X48 CLR. <br />7 <br />A-2 <br />3,4 <br />A-1 <br />17 <br />101A <br />3 <br />2 <br />TYP. <br />4 <br />5 <br />MINIMUM NUBER OF PLUMBING FIXTURES PER CPC TABLE 422.1 <br />PLUMBING FIXTURE COUNT <br />TOTAL OCC.LOAD = 28 <br />CPC TABLE 422.1 EXCEPTION (3)ONLY ONE EACH WOMEN'S &MEN'S <br />TOILET ROOM REQUIRED <br />PLUMBING FIXTURE COUNT <br />WATER CLOSET LAVATORY URINAL <br />REQ'D PROV'D REQ'D PROV'D REQ'D PROV'D <br />ALL GENDER RR 1 1 1 1 <br />6 <br />8 <br />101B <br />101B <br />101B <br />101C <br />101C <br />101C <br />101D <br />3 NEW <br />13 <br />11VITREOUS CHINALAVATORYKATHRYNK-2330 <br />(N) SINK <br />36 <br />X <br />4 <br />8 <br /> <br />C <br />L <br />R <br />. <br />13 <br />(E.) FIXED EXTERIOR GLAZING BEHIND NO CHANGE <br />(E.) EXTERIOR STRUCTURAL WALLS NO CHANGE <br />(E) INTERIOR NON-BEARING PARTITION TO BE REMAIN <br />(E.) & (N.) FLOOR PLAN WALL LEGEND: <br />1 <br />2 <br />3 <br />4 <br />5 <br />STACKABLE W/D <br />6 <br />7 <br />8 EXISTING ELEC. SUB PANEL <br />EMPLOYEE LOCKER. 2022 CBC-11B-225.2.1 <br />EQUIPMENT FLOOR PLAN KEY NOTES: <br />Where lockers are provided, at least 5 <br />percent, but no fewer than one of each <br />type, shall comply with Section 11B-811. <br />9 <br />HAIR SPA STATION <br />STYLING STATION <br />ACCESSIBLE DRINKING DESPENSER <br />FULL ACCESSIBLE RECEPTIONIST COUNTER <br /> SERVICE SINK <br />NEW ELEC. WATER HEATER TANK TYPE <br />CHAIR <br />10 <br />11 <br />ACCESSIBLE SIGNAGE KEY NOTES <br />MAIN EXIT DOOR SHALL PROVIDED WITH A DURABLE SIGN OF <br />ONE (1") LETTERS ON CONTRASTING BACKGROUND <br />INDICATING ( THESE DOORS SHALL REMAIN UNLOCKED WHEN <br />THIS SPACE IS OCCUPIED) PER SEC. 1008.1.9.3 <br />1 <br />TACTILE EXIT SIGN W./ WORDS "EXIT" (1011.1, 1011.4.9(4))2 <br />INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGNAGE.3 <br />THIS TABLE TO BE OPEN AT ALL TIMES FOR CUSTOMER WITH <br />DISABILITIES CLEAR FOR ACCESSIBLE AT COUNTER MAX. 34" <br />HIGH AND 36" WIDE <br />4 <br />FLOOR PLAN NOTES: <br />1.WALL AND CEILING MATERIALS SHALL NOT EXCEED THE <br />FLAME SPREAD CLASSIFICATIONS IN CBC TABLE 803.9 <br />2.DOORS SHALL BE READILY OPENABLE FROM THE <br />EGRESS SIDE WITHOUT THE USE OF A KEY OR ANY <br />SPECIAL KNOWLEDGE OR EFFORT IN CBC TABLE <br />1008.1.9) <br />3.ALL CABINETS MILLWORKS DRAWING AND INSTALLATION <br />BY OTHER <br />4.ALL BASE CABINETS SHALL BE @ 34" MAX. HEIGHT <br />5.NO HAZARDOUS MATERIALS WILL BE STORED AND/ OR <br />USED WITHIN THE BUILDING,WHICH WILL EXCEED THE <br />QUANTITIES LISTED IN CBC 414.2.5(1) <br />6.THERE WILL NOT BE ANY DIAMOND PLATE ON THE WALK <br />IN UNIT DOORS OR WALLS. <br />INDICATES TOTAL CAPACITY POSTED "MAXIMUM <br />OCCUPANT LOAD 12 PERSON"5 <br />6 <br />ALL EXTERIORS ARE SELF-CLOSING, <br />TIGHT-FITTING RODENT-PROOF7 <br />RESTROOM VENTILATION IS LIGHT SWITCH <br />ACTIVATED MECHANICAL EX. FAN8 <br />EXIT SIGNAGE TO COMPLY PER CBC SECTION 1013 <br />TOTAL OCCUPANT = 28< 50 <br />EXIT REQUIRED : 1 PROVIDED :2 <br />OCCUPANCY LOAD CBC 2022, 1004.5, 1004.6 <br />STYLING STATION + STYLIST <br /># OF SEATFIXED SEATING <br />5 <br />SPA STATION 8 <br />1 <br />2 <br />3 <br />TOTAL OCCUPANCY LOAD 27.5 <br />0.5 <br />4 <br />RECEPTION AREA <br />5 <br />5 <br />WAITING AREA <br />5BREAK ROOM <br />75 SF 150 SF <br /> 15 SF <br />15 SF <br />81 SF <br />83 SF <br />FOOT SOAK 4 <br />LASH CHAIR12 <br />FACIAL CHAIR13 <br />Accessible sink: Per Section 11B-804, non-commercial <br />kitchen sinks (such as at employee break rooms, etc.) shall <br />provide the following: <br />a)A clear floor space of at least 30”x 48” shall be <br />provided for forward approach and shall be on an accessible <br />route. The clear space shall extend a maximum of 19” <br />underneath the sink. Section 11B-606.2. <br />b)The accessible sink shall be mounted with the counter <br />or rim no higher than 34” above the finish floor. Knee <br />clearance that is at least 27” high, 30” side and 19” <br />underneath the sink shall be provided. Hot water and drain <br />shall be insulated or otherwise configured so as to protect <br />against contact. There shall be no sharp or abrasive surfaces <br />under the sink. Section 11B-606. <br />c)Faucet controls and operating mechanisms shall be <br />operable with one hand and shall not require tight grasping, <br />pinching, or twisting of the wrist. Lever operated, push-type <br />and electronically controlled mechanisms are acceptable. <br />Self-closing valves are allowed if the faucet remains open for <br />at least 10 seconds. Section 11B-606.4. <br />N <br />NEW INTERIOR NON-BEARING PARTITION. <br />(E) INTERIOR NON-BEARING PARTITION TO BE REMOVED <br />EXISTING WALLS AND DOOR TO BE REMAIN <br />1 <br />1S <br />T <br /> <br />C <br />O <br />R <br />R <br />E <br />C <br />T <br />I <br />O <br />N <br />08 <br />. <br />2 <br />9 <br />. <br />2 <br />5 <br />1 <br />1 <br />1 <br />1 <br />101B