ALL NOTES ARE TYPICAL THROUGHOUT: <br />1. REFERENCE GENERAL NOTES ON IA-G1 AND IA-G-2 FOR ADDITIONAL INFORMATION <br />2. VERIFY EXISTING CONDITIONS AND NOTIFY H. HENDY ASSOCIATES OF ANY DISCREPANCIES. <br />3. WORK SHALL COMPLY FULLY WITH ALL APPLICABLE NATIONAL, STATE AND LOCAL CODES. <br />4. PROVIDE LEVEL-5 FINISH AT ALL GYP. BOARD CEILINGS/SOFFITS, U.O.N. <br />5.INSTALL R30 BATT INSULATION AND SCRIM AT UNDERSIDE OF EXISTING ROOF DECK. SCRIM COLOR: WHITE. <br />6.SEE DETAILS 2/ IA-7.1, 3/IA-7.1, AND 4/ IA-7.1 FOR SUSPENDED CEILING DETAILS <br />CEILING NOTES <br />2 <br />EXISTING 2 X 4 SUSPENDED CEILING GRID TO REMAIN. REPLACE EXISTING ACCOUSTICAL TILES WITH <br />NEW TILES COMPATIBLE WITH EXISTING GRID. SEE NOTE 6.4 FOR ADDITIONAL INFORMATION <br />CEILING HEIGHT <br />EXPOSED CEILING <br />ILLUMINATED EXIT SIGNS, DIRECTIONAL ARROW WHERE INDICATED. TIED TO BUILDING LIFE <br />SAFETY OR BATTERY BACKUP. <br />FOR EMERGENCY LIGHTING, REFER TO ELECTRICAL ENGINEERING PLANS. <br />AREA NOT IN CONTRACT <br />LEGEND <br />X'-X" <br />EXP. <br />EXISTING 2 X 2 SUSPENDED CEILING GRID TO REMAIN. REPLACE EXISTING ACCOUSTICAL TILES WITH <br />NEW TILES COMPATIBLE WITH EXISTING GRID. SEE NOTE 6.4 FOR ADDITIONAL INFORMATION <br />EXISTING 2 X 4 FLOURESCENT FIXTURE. REMOVE AND REPLACE WITH NEW LED FIXTURE. SEE <br />ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION <br />EXISTING 2 X 2 FLOURESCENT FIXTURE. REMOVE AND REPLACE WITH NEW LED FIXTURE. SEE <br />ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION <br />NEW 2X4 LED FIXTURE. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION <br />EXISTING FLOURESCENT CAN LIGHT. REMOVE AND REPLACE WITH NEW LED FIXTURE <br />EXISTING FLOURESCENT WALL WASHER FIXTURE. REMOVE AND REPLACE WITH NEW LED FIXTURE <br />NEW 2X4 SUSPENDED CEILING SYSTEM TO MATCH EXISTING <br />EXISTING METAL HALIDE HIGH BAY LIGHT FIXTURE. REMOVE AND REPLACE WITH NEW LED HIGH BAY <br />FIXTURE. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION <br />EXISTING FLOURESCENT STRIP LIGHT TO REMAIN <br />EXISTING FLOURESCENT FIXTURE TO REMAIN. <br />1.REMOVE ALL UNUSED WIRES, HANGERS, STRAPS, CLIPS, SCREWS, CABLING, CONDUITS OR ELECTRICAL WIRES <br />AT EXPOSED CEILING CONDITIONS. <br />2.REMOVE INSULATION AT EXISTING DUCTWORK WHERE OCCURS. CLEAN EXTERIOR OF DUCTWORK AND PREP TO <br />RECEIVE PAINT, U.N.O. <br />3.COORDINATE EXISTING DRAFT STOPS AT EXPOSED CEILING CONDITIONS WITH ARCHITECT. <br />4.PROVIDE RIGID DUCTWORK WITH SIDE DUCT MOUNTED SUPPLY DIFFUSERS AT ALL EXPOSED CEILING <br />CONDITIONS, U.N.O. PROVIDE CUT SHEETS TO ARCHITECT FOR APPROVAL PRIOR TO ORDERING AND <br />INSTALLATION. <br />5.PROVIDE ALUMINUM STRAPS TO MATCH ALUMINUM DUCTWORK FOR COVERING ALL DUCT SEALANT LOCATIONS, <br />U.N.O. <br />6.ALL VISIBLE PIPING, DUCTS AND CONDUITS IN EXPOSED CEILING CONDITIONS SHALL HAVE 90 DEGREE ANGLES <br />INSTEAD OF SHORTEST DISTANCE PATH. <br />7.PAINT ALL EXPOSED DUCTWORK, CONDUIT, PIPES, DECKING, SUPPORT BEAMS, ETC., U..N.O. REFER TO FINISH <br />LEGEND FOR PAINT SPECIFICATION. <br />8.WHERE INSULATION IS REQUIRED BY CODE, PROVIDE BATT INSULATION WITH SCRIM AT UNDERSIDE OF DECK IN <br />ALL EXPOSED CEILING CONDITIONS AT UNDERSIDE OF ROOF. COLOR OF SCRIM SHALL BE SELECTED BY <br />ARCHITECT. <br />9.EXTEND EXISTING WALLS AND FURRING SURROUNDING EXPOSED CEILING FULL HEIGHT TO UNDERSIDE OF DECK <br />ABOVE AS REQUIRED FOR CONSISTENT APPEARANCE. EXPOSED KICKERS SHALL BE AVOIDED. <br />10.COORDINATE LIGHT FIXTURE AND EXIT SIGN LOCATIONS IN ALL EXPOSED CEILINGS PRIOR TO ROUGH-IN TO <br />CONFIRM LOCATIONS AND ANY POSSIBLE HEIGHT LIMITATIONS. NOTIFY ARCHITECT OF ANY CONFLICTS. <br />11.PROVIDE ALLOWANCE FOR MOUNTING LIGHT FIXTURES AND EXIT SIGNS UNDER UNI-STRUT AS NEEDED TO <br />MAINTAIN FIXTURE LOCATIONS AT OBSTRUCTIONS. <br />EXPOSED CEILING NOTES <br />1 <br />A <br />B <br />C <br />D <br />C.6 <br />C.5 <br />2 3 4 5 6 <br />201 <br />OFFICE <br />200 <br />EXECUTIVE OFFICE <br />202 <br />LOUNGE <br />203 <br />RESTROOM <br />204 <br />STORAGE <br />206A <br />VETIBULE <br />205 <br />STOR <br />206 <br />OPEN OFFICE <br />207 <br />OFFICE <br />208 <br />MEN <br />209 <br />WOMEN <br />210 <br />JAN <br />+9'-0" <br />+9'-0" <br />+9'-0" <br />+9'-0" <br />+9'-0" <br />+9'-0" <br />+9'-0" <br />+9'-0" <br />+9'-0" <br />+9'-0" <br />+8'-0" <br />+8'-0" <br />NORTH <br />HHENDY.COM <br />T (949) 851-3080 <br />4770 Campus Dr., Suite 100 <br />Newport Beach, CA 92660 <br />H ndy <br />ISSUES AND REVISIONS <br />JOB NUMBER <br />SCALE <br />PROJECT <br />TEAM <br />All specifications, drawings, concepts, designs, arrangements, intellectual and written material represented herein constitute <br />unique and unpublished work of H. Hendy Associates and may not be copied, used by or disclosed to others without written <br />consent of H. Hendy Associates. <br /> 2023 H.HendyAssociatesc <br />DATE <br />1/8" = 1'-0" <br />04463.0000.24 <br />3080 S. HARBOR BLVD. <br />SANTA ANA, CA 92704 <br />LEVEL 2 REFLECTED CEILING PLAN <br />IA-2.2 <br />MCGUFF <br />AB/CD <br />NO. DESCRIPTION DATE <br />PLAN CHECK SUBMITTAL 3/17/25