Permit Number
101123703
101123704
Full Address
3080 S Harbor Blvd
Street Number
3080
Street Direction
S
Street Name
Harbor
Street Suffix
Blvd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
187
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Section : 362S162-43 (33 ksi) @ 16" o.c. Single C Stud (punched) <br />Maxo =612.0 ft-lb 1739.1 lbVa =I =0.71 in^4 <br />Loads have not been modified for strength checks <br />Loads have been multiplied by 0.70 for deflection calculations <br />Bridging Connectors - Design Method =AISI S100 <br />Span KyLy, KtLt <br />Flexual, <br />Distortional Connector <br />Stress <br />Ratio <br />Axial <br />Span 60.0", 60.0"60.0", 132.0"LSUBH3.25 (Min)0.54 <br />Web Crippling <br />Support Load (lb)(in)Max Int.Stiffener? <br />Bearing Pa M <br />(lb)(ft-lbs) <br />R2 112.64 --Shear Connection w/ clip--NO <br />R1 112.64 --Stud/Track Design, Ref Connectors--NO <br />Gravity Load <br />Type Load (lb) <br />Uniform 28.00plf <br />Code Check Required Interaction NotesAllowed <br />Max. Axial, lbs 308.0(c)14%KΦ=0.00 lb-in/in Max KL/r = 982169.1(c)Span <br />Max. Shear, lbs 112.6 17%Shear (Punched)675.7 <br />Max. Moment (MaFy, Ma-dist), ft-lbs 309.8 51%MaFy (control),KΦ=0.00 lb-in/in612.0 <br />Moment Stability, ft-lbs 309.8 56%553.1 <br />Shear/Moment 0.51 51%Shear 0.0, Moment 309.81.00 <br />Axial/Moment 0.63 63%Axial 163.9(c), Moment 308.51.00 <br />Deflection Span, in 0.226 --meets L/585-- <br />Support Rx(lb)Ry(lb)Simpson Strong-Tie Connector <br />Connector <br />Interaction <br />Anchor <br />Interaction <br />10.10 %R2 112.6 0.0 18.47 %SCB45.5(2) & (2) #12-24 SST X or XL to A36 Steel <br />51.15 %R1 112.6 308.0 25.82 %362T125-33 (33) & (1) .157" SST PDPA/PDPAT-62KP to <br />steel (3/16" to 1/2" thickness) <br />* Reference catalog for connector and anchor requirement notes as well as screw placement requirements <br />www.strongtie.comSIMPSON STRONG-TIE COMPANY INC. <br />Project Name:McGuff CFS Designer <br />Model:Exterior Wall Stud <br />2012 NASPEC [AISI S100-2012]Code: <br />Page 1 of 1 <br />Date: 03/12/2025 <br />Simpson Strong-Tie® CFS Designer™ 5.2.7.0