Laserfiche WebLink
Client: Verizon Wireless Date: 11/1/2024 <br />Site Name: Santa Ana MTSO <br />MDG #: 5000377172 <br />Fuze ID #: 17356224 Page: 1 <br />Version 2.00 <br />I. Mount-to-Tower Connection Check <br />Custom Orientation Required Yes <br />Nodes <br />(labeled per Risa) <br />Orientation <br />(per graphic of typical platform) <br />N98 0 <br />N100 0 <br />Tower Connection Bolt Checks Yes <br />Bolt Orientation Parallel <br />4 <br />5.125 <br />3 <br />A36 <br />0.625 <br />3.5 <br />0.8 <br />10.0 <br />6.0 <br />34.8% <br />Tower Connection Baseplate Checks No <br />Shear Capacity / bolt (kips): <br />Bolt Overall Utilization: <br />Tensile Capacity / bolt (kips): <br />Bolt Quantity per Reaction: <br />dx (in) (Delta X of typ. bolt config. sketch): <br />dy (in) (Delta Y of typ. bolt config. sketch): <br />Bolt Type: <br />Bolt Diameter (in): <br />Required Tensile Strength / bolt (kips): <br />Required Shear Strength / bolt (kips):