THREADED <br />ROD (TYP.) <br />EXCESS CABLE MIN <br />1" (TYP) <br />EXCESS CABLE <br />MIN 1" (TYP) <br />EXCESS CABLE <br />MIN 1" (TYP) <br />FORGED WIRE ROPE <br />CLIP. INSTALL TWO PER <br />CABLE END <br />1/8" WIRE ROPE (TYP) <br />THIMBLE <br />(TYP) <br />1/8" WIRE ROPE <br />(TYP) <br />FORGED WIRE ROPE CLIP. INSTALL <br />TWO PER CABLE END <br />ADJUSTABLE PIPE STAND <br />STEEL OFFSET <br />WALL BRACKET <br />CONCRETE ANCHOR <br />CONCRETE ANCHOR (TYP OF 2) <br />NOTES: <br />1. PIPING SUPPORTS SHALL MEET ALL STATE AND LOCAL SEISMIC RESTRAINT REQUIREMENTS. <br />2. COORDINATE ANCHORAGE REQUIREMENTS WITH STRUCTURAL DESIGN. <br />3. PROVIDE SEISMIC CABLE TRANSVERSE BRACING AT 40 FEET. AND EACH CHANGE OF DIRECTION. <br />4. SEISMIC CABLE LONGITUDINAL BRACING AT 80 FEET. AND EACH CHANGE OF DIRECTION. <br />5. MAXIMUM ROD SPAN BETWEEN SUPPORTS IS 10'. CLOSER SPAN AS REQUIRED BY SPECIFICATIONS AND SMACNA. <br />6. PROVIDE TRANSVERSE AND LONGITUDINAL BRACES AT 40 FEET MAXIMUM FOR PIPES SMALLER THAN 4 IN. AND AT <br />20 FEET MAXIMUM FOR PIPES 4 TO 8 INCHES. <br />7. SEISMIC CABLE RESTRAINTS ARE NOT REQUIRED AT EVERY HANGER LOCATION. VERTICAL HANGERS, DIAGONAL <br />AND HORIZONTAL BRACES TO BE SIZED IN ACCORDANCE WITH SMACNA SEISMIC RESTRAINT MANUAL. <br />8. SEISMIC BRACING REQUIRED FOR PIPE SIZE 2-1/2" AND LARGER. <br />WALL BRACKET <br />U-BOLT <br />PEDESTAL BRACKET <br />U-BOLT <br />TRAPEZE <br />CLEVIS <br />1" <br />STEEL CLEVIS <br />1" <br />STEEL STRAP <br />U-BOLTS <br />1" <br />THIMBLE (TYP) <br />CL <br />NOTES: <br />1. REFER TO PLANS FOR SIZES AND CONTINUATION. <br />2. COORDINATE ANCHORAGE REQUIREMENTS WITH STRUCTURAL <br />DESIGN. <br />PIPE <br />SECTION <br />3/4" STEEL <br />PLATE (TYP) <br />BUILDING STRUCTURE <br />(TYP) <br />5/8" DIAMETER A325 <br />BOLTS (TYP) <br />ELEVATION <br />8" <br />W <br />A. <br />L <br />. <br />D <br />. <br />A <br />3A <br />DOUBLE THICKNESS TURNING <br />VANES <br />ROUND ELBOW W/ TURNING <br />BLADES IF W > 18" <br />ADJUSTABLE TAP <br />DAMPER <br />OFFSET IN VERTICAL PLANE SHALL BE <br />MADE WITH SMOOTH FITTINGS. ARROW <br />IN DIRECTION OF AIRFLOW. <br />OFFSET IN HORIZONTAL PLANE <br />SHALL BE MADE WITH SMOOTH <br />FITTINGS. <br />PLENUM OVER DIFFUSER <br />CONICAL FITTINGS <br />REGULATION OF VOLUME DAMPER <br />SHALL BE ACCESSIBLE THROUGH THE <br />FACE OF DIFFUSER <br />ACCESS DOOR IN DUCT <br />FLD MOUNTING TYPE DEPENDS ON AIR <br />VELOCITIES AND DUCT SIZE - SEE <br />SPECIFICATIONS. RATING EQUAL TO <br />PARTITION UNLESS NOTED OTHERWISE. <br />(2HR MIN.) <br />COIL WITH FLANGED CONNECTION ALL AROUND <br />DIRECTION OF FLOW <br />ACCESS DOORS <br />NOTE: INSTALL ELECTRIC <br />DUCT HEATERS 2'-0" MIN FROM <br />ANY FANS, ELBOWS, OR "T" <br />FITTINGS. <br />VOLUME DAMPER <br />AUTOMATIC LOUVER DAMPER <br />(MOTORIZED DAMPER) <br />BDD - BACKDFAFT DAMPER <br />TRANSITION <br />FLEXIBLE CONNECTION <br />INTERLOCK WITH HEAT PUMP UNIT. IN <br />HEATING MODE RADIANT SHALL BE <br />ENERGIZED AS SECOND STAGE <br />SOLID CROSS INDICATES UP OR TOWARD. DASHED <br />CROSS INDICATES DOWN OR AWAY. <br />SUPPLY RETURN OR EXHAUST <br />GRILLE, REGISTER AND DIFFUSER SYMBOLS: <br />SQUARE CEILING SUPPLY <br />DIFFUSER OR REGISTER <br />ROUND CEILING SUPPLY <br />DIFFUSER OR REGISTER <br />CEILING RETURN OR <br />EXHAUST GRILLE OR <br />REGISTER <br />SIDEWALL SUPPLY <br />REGISTER <br />SIDEWALL RETURN OR <br />EXHAUST GRILLE OR <br />REGISTER <br />TYPE (SEE SCHEDULE) <br />∅NECK SIZE OR WIDTH X HEIGHT OR SLOT X LENGTH <br />CFM <br />A 8 <br />300 <br />ELECTRIC RADIANT HEAT (TYP.) <br />BDD <br />AL <br />D <br />VD VD <br />AL <br />D <br />BDD <br />HEATING COIL <br />HTG. COIL <br />FIRE DAMPER <br />FIRE RATED <br />WALL <br />FLD <br />FLD <br />PLENUM <br />OVER <br />DIFFUSER <br />CONN. TO LINEAR <br />DIFFUSER PLENUM <br />HORIZONTAL <br />OFFSET <br />RISE OR DROP <br />ELEVATION <br />SUPPLY <br />TAP TAKE-OFF <br />ELBOW R = 3W/4 <br />RETURN <br />RI <br />S <br />E <br />OR <br />DO <br />W <br />N <br />WHERE DUCTWORK IS SHOWN SINGLE LINE, FOLLOWING SHALL APPLY FOR ACTUAL DUCT CONSTR. <br />SINGLE LINE ACTUAL CONSTRUCTION <br />CU <br />FCU <br />CU <br />ROOF/ <br />GRADE <br />INDOOR FAN COIL <br />ROOF MOUNTED CONDENSING UNIT <br />CONDENSATE DRAIN TO <br />NEAREST FLOOR DRAIN <br />PAD OR CURB <br />REFRIGERANT PIPING <br />NEOPRENE OR <br />FIBERGLASS MOUNT <br />WALL-HUNG CONDENSING UNIT <br />NOTES: <br />1. INSTALL CONDENSING UNIT TO MAINTAIN A MINIMUM OF 12" CLEAR BEHIND CONDENSING UNIT AIR INTAKE. <br />2. MOUNT WALL-HUNG CONDENSING UNIT APPROX. 8' AFF. <br />3. SECURLY BOLT CONDENSING UNIT TO STRUCTURE. <br />12" MIN. <br />FULL SIZE <br />NEOPRENE OR FIBER <br />GLASS MOUNT <br />0.5" DEFLECTION <br />T <br />A <br />A <br />A <br />A <br />A <br />NOTES: <br />1. TRANSFER DUCT SHALL BE SHEET METAL CONSTRUCTION. <br />2. SIZE TRANSFER DUCT FOR MAXIMUM 500 FPM VELOCITY: <br />A = 14", 500 CFM <br />A = 20", 1125 CFM <br />A = 26", 2000 CFM <br />1" ACOUSTICAL <br />LINING <br />1.5 X A <br />NO CLEAR SIGHT <br />LINE THROUGH <br />DUCT <br />DIR SUPPLY DUCT <br />(FROM FAN <br />POWERED <br />TERMINAL UNITS) <br />25mm <br />ACOUSTICAL <br />DUCT LINING <br />FLEXIBLE DUCT <br />VOLUME <br />DAMPER <br />SUPPLY <br />PLENUM <br />PERIMETER LINEAR DIFFUSER <br />GLASS <br />CEILING <br />NOTES: <br />1.ALL EXPOSED SURFACES SHALL <br /> BE FLAT BLACK. <br />PROVIDE MOUNTING FLANGE ON <br />DUCT FOR FASTENING OF DUCT SO <br />EDGE OF GRILLE BORDER FLANGE IS <br />FLUSH WITH OUTSIDE FACE OF DUCT <br />DUCT-MOUNTED GRILLE <br />DUCT- <br />MOUNTED <br />VOLUME <br />DAMPER <br />RECTANGULAR <br />ANGLE TAP <br />AI <br />R <br />F <br />L <br />O <br />W <br />45 <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2021 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />EXP: 12/31/2025 <br />N.T.S <br />6/12/2024 7:44:36 AM <br />BIM 360://007.3757.000 - Caribou Industries - 3rd & Broadway/228011-04_3RD-B_MECH_R20.rvt <br />R2.M9.001 <br />MECHANICAL DETAILS <br />228011-04 <br />3rd & Broadway Residential <br />Tower Tenant Interiors <br />1103 North Broadway <br />Santa Ana, CA 92701 <br />SCALE: N.T.S1PIPE SUPPORTS <br />SCALE: N.T.S2RISER SUPPORT <br />SCALE: N.T.S3DUCTWORK SYMBOLS & STANDARDS <br />SCALE: N.T.S4SPLIT SYSTEM <br />SCALE: N.T.S5TRANSFER DUCT <br />SCALE: N.T.S7TYPICAL SUPPLY DIFFUSER CONNECTION <br />SCALE: N.T.S8TYPICAL SUPPLY DIFFUSER CONNECTION <br />1 <br />06.13.2022 ISSUE FOR PLAN CHECK <br />1 06.17.2024 REVISION TO PERMIT <br />1/15/2025