Laserfiche WebLink
? <br />? <br />R09R10R11R12R13R14R15R16R17 <br />RF <br />RG <br />RH <br />RJ <br />RK <br />RL <br />R07R08R11' <br />STAIR 01 <br />R16D23 <br />VESTIBULE <br />R15H11 <br />STAIR 02 <br />R35 <br />ELEVATOR <br />LOBBY <br />R15H10 <br />STORAGE <br />R15H09 <br />ELEVATOR <br />03 <br />R38 <br />TRASH <br />ROOM <br />R15F16 <br />VESTIBULE <br />R15H15 <br />ELEVATOR <br />LOBBY <br />R15H14 <br />ELEVATOR <br />01 <br />R154 <br />ELEVATOR <br />02 <br />R155 <br />4"RD-1 <br />4"OD-1 <br />(700 SF) <br />4"RD-1 <br />4"OD-1 <br />(700 SF) <br />4"RD-1 <br />4"OD-1 <br />(700 SF) <br />4"RD-1 <br />4"OD-1 <br />(750 SF) <br />1 <br />1 <br />1 <br />6" SD DN <br />6" OD DN <br />6" SD DN <br />6" OD DN <br />6" SD DN <br />6" OD DN <br />6" SD DN <br />6" OD DN <br />6" SD UP <br />6" OD UP6" OD UP <br />6" SD UP <br />6" OD UP <br />6" SD UP <br />6" OD UP 6" SD UP <br />1 <br />1 1/2" MG DN <br />1 1/2" MG UP <br />6" PCW DN <br />6" PCW UP <br />2" SS UP <br />2" SS UP <br />SEE IRRIGATION PLANS <br />FOR POC ON L14. <br />SOV <br />1 <br />2BR_2 <br />R15G16 <br />2BR_1 <br />R15F15 <br />2BR_1 <br />R15F13 2BR_1 <br />R15F12 <br />ST_1 <br />R15F11 <br />2BR_1 <br />R15F10 <br />ALL <br />GENDER RR <br />R15F09C <br />VESTIBLE <br />R15F09B <br />ALL <br />GENDER RR <br />R15F09A <br />JANITOR <br />R15F09D <br />STORAGE <br />R15J10 <br />2BR_1 <br />R15J11 <br />ST_1 <br />R15H12 <br />2BR_1 <br />R15H13 <br />SOV <br />23 <br />SOV <br />22 <br />SOV <br />21 <br />SOV <br />20 SOV <br />19 <br />SOV <br />18 <br />SOV <br />17 <br />SOV <br />2 <br />SOV <br />4 <br />SOV <br />5 <br />SOV <br />6 <br />SOV <br />7 SOV <br />8 <br />SOV <br />9 <br />SOV <br />10 <br />SOV <br />11 <br />REFER TO REHEAT <br />STATION PIPING <br />DIAGRAM DETAIL 8 ON <br />SHEET R1-P9.4 FOR <br />CONTINUATION <br />3/4" CD <br />2 <br />15A-15 <br />FC <br />SOV <br />13 <br />SOV <br />14 <br />2 <br />2 <br />2 2 <br />2 <br />2 <br />2 <br />2 <br />2 <br />2 <br />2 <br />2 <br />2 <br />2 <br />2 <br />2 <br />2 <br />1" HWR UP <br />4" HW UP <br />4" CW UP <br />SHEET NOTES GENERAL NOTES KEY PLAN <br />Ref North <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2015 <br />NOT FOR <br />CONSTRUCTION <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />Job No.: <br />Contact: <br />www.glumac.com <br />18200 Von Karman Ave., Suite 100 <br />Irvine, CA 92612 <br />T. 949.833.8190 <br />1/8" = 1'-0" <br />6/12/2024 7:39:44 PM <br />BIM 360://007.3757.000 - Caribou Industries - 3rd & Broadway/3RD-B_MEP_WEST_R20.rvt <br />R1-P2.115 <br />PLUMBING PLAN - LEVEL 15 <br />21US00608 <br />3rd & Broadway West <br />1103 North Broadway <br />Santa Ana, CA 92701 <br />21US00608 <br />TG <br />SCALE:1/8" = 1'-0" <br />PLUMBING PLAN - LEVEL 151 0 8' -0"16' -0"24' -0"32' -0" <br />1 9/21/2021 REISSUE FOR PLAN CHECK <br />2 01/18/2022 REISSUE FOR PLAN CHECK <br />4 06/17/2024 REVISION TO PERMIT <br />1 3/4" CD FROM ABV AND DN THRU FLOOR. <br />2 VENT THROUGH ROOF IN LOCATION MIN. 10 FT <br />AWAY FROM ANY WINDOW, DOORWAY, OR AIR <br />INTAKE. LOCATE MIN. 1 FT AWAY FROM ANY <br />VERTICAL SURFACE. SOVENT VENTING SHALL <br />CONFORM WITH MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS. <br />4 <br />EOR: SEAN AGUON <br />LIC#: M41274 <br />10/11/2024