301 N Broadway - Apt TI - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Broadway
>
301 N Broadway
>
301 N Broadway - Apt TI - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:47 AM
Creation date
2/13/2026 5:00:39 AM
Metadata
Fields
Template:
Plan
Permit Number
101120329
Full Address
301 N Broadway
Street Number
301
Street Direction
N
Street Name
Broadway
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
167
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SCALE: NONE1RESIDENTIAL BUILDING'S TYPICAL SOVENT RISERS <br />10TH TO 12TH FL <br />9TH FL <br />13TH TO 15TH FL <br />16TH FL <br />10TH TO 12TH FL <br />9TH FL <br />13TH TO 15TH FL <br />16TH FL <br />Top View <br />Side View <br />4'' Sovent Stack <br />4'' Deaerator Fitting <br />Fin Floor <br />Tite Ruff 3" PRL <br />Less than 20' <br />Sinks - Vertical Branch <br />Sinks - Horizontal Branch <br />Lavatories - Vertical Branch <br />Lavatories - Horizontal Branch <br />Detail "A-A"Detail "B-B" <br />Detail "A-A" <br />Lc <br />Lcc <br />cL <br />L <br />Min. Elev. Reqmts. <br />Pressure Relief Line <br />one pipe size <br />More than 20ft., Increase <br />Lc <br />3 in. Stack, Min. 30 in. <br />4 in. Stack, Min. 40 in. <br />Lc <br />Pressure Relief Line <br />Min. Elev. Reqmts. <br />Lc Lc <br />More than 20' <br />More than 20', Increase <br />one pipe size <br />3 in. Stack, Min. 30 in. <br />4 in. Stack, Min. 40 in. <br />12' max. <br />12 ft. max.* <br />Remainder <br />15 ft. max. <br />13.5" <br />13 <br />. <br />8 <br />7 <br />5 <br />" <br />18 <br />. <br />6 <br />2 <br />5 <br />" <br />CL LC <br />4.5" <br />9.65" <br />8.5" <br />9.65"CL LC <br />C <br />9.65" <br />13.5" <br />D <br />A <br />B <br />cLcL <br />Lc <br />Lc <br />SOV <br /> # <br />SOV <br /> # <br />A <br />B <br />A <br />DeAerator <br />(P.R.L.) <br />Pressure <br />Relief Line <br />Building Drain <br />B3" PRL <br />Main Bldg. Drain <br />Branch Waste Line <br />Centerline of Main Bldg. Drain <br />Must Connect Above Horizontal <br />1-1/2'' <br />2'' <br />2'' <br />2'' <br />(typ) <br />2'' <br />(typ) <br />1-1/2'' <br />2'' <br />2'' <br />1-1/4'' <br />(typ) <br />2''1-1/2'' <br />2'' <br />1-1/2'' <br />(typ) <br />1-1/2''1-1/4'' (typ) <br />2'' <br />4'' <br />5'' <br />4'' <br />4'' <br />Vent Thru Roof <br />4" <br />DeAerator <br />B <br />A <br />A <br />B <br />4'' <br />4'' <br />Builiding Drain <br />(P.R.L.) <br />A <br />as req'd. <br />cleanout <br />A <br />DeAerator <br />Pressure <br />Relief Line <br />4'' <br />4'' <br />5'' <br />5'' <br />4'' <br />4" <br />4'' <br />use of 3 in. pipe for 1.6 GPF toilet systems. <br />on 4 in. soil branch, it is recommended to maximize <br />Note: Sovent criteria allows 27 ft. max. distance <br />SoventStack <br />Stack <br />Sovent <br />* <br />Aerator <br />*4'' <br />3'' <br />WC <br />2'' <br />WC <br />*3'' <br />3''* <br />WC <br />LAV <br />Stack <br />4'' Sovent <br />2'' Waste, Max. 15'-0" <br />3'' Waste, Max 15'-0" <br />2'' Waste, Max. 15'-0" <br />2'' Waste, Max. 15'-0" <br />4'' Soil, Max 27'-0" <br />3'' Soil, Max. 12'-0" <br />Aerator <br />WC <br />on 4" Stack <br />4'' SoventStack <br />* <br />D <br />C <br />B <br />A <br />Sovent Box <br />with <br />Variable Recess <br />Aerator Fitting <br />12.50" <br />30.75" <br />20.75" <br />16"13" <br />17.75" <br />24.75 <br />9.75"9.75" <br />24.75" <br />16.75" <br />10.50" <br />6.75" <br />19.50" <br />10" <br />5"4"4"x3" <br />13.25" <br />3" <br />Variable* <br />Tite-Ruff TM <br />Vent Thru Roof <br />Vent Thru Roof <br />SE4-DEA <br />4" DEAERATOR <br />C/O <br />4" VTR <br />4" <br />LAV <br />LAV <br />3" <br />SE4X3ABCDG <br />4" AERATOR <br />WC <br />LAV <br />4" <br />SE4X3ABCDG <br />4" AERATOR <br />SE4X3ABCDG <br />4" AERATOR <br />2" <br />2" <br />KS <br />CW <br />2" <br />3" <br />3" <br />TUB <br />2" <br />WC <br />3" <br />TUB <br />2" <br />LAV <br />3" <br />WC <br />LAV <br />2" <br />2" <br />KS <br />CW <br />2" <br />3" <br />3" <br />TUB <br />2" <br />WC <br />3" <br />TUB <br />2" <br />LAV <br />3" <br />WC <br />LAV <br />2" <br />2" <br />KS <br />CW <br />2" <br />3" <br />3" <br />TUB <br />2" <br />WC <br />3" <br />TUB <br />2" <br />LAV <br />WC <br />LAV <br />2" <br />2" <br />KS <br />CW <br />2" <br />TUB <br />2"WC <br />TUB <br />2" <br />4" <br />4" <br />3" PRL <br />(120 F.U. ) 4" <br />3"4" <br />SE4-DEA <br />4" DEAERATOR <br />C/O <br />4" VTR <br />4" <br />SE4X3ABDG <br />4" AERATOR <br />4" <br />SE4X3ABDG <br />4" AERATOR <br />SE4X3ABDG <br />4" AERATOR <br />3" <br />WC <br />2" <br />CW <br />TUB <br />WC <br />4" <br />4" <br />3" PRL (80 F.U. ) 4" <br />4" <br />2" <br />LAV <br />KS <br />2" <br />2" <br />3" <br />3" <br />2" <br />2" <br />2" <br />2" <br />CW <br />TUB <br />2" <br />LAV <br />KS <br />2" <br />2" <br />3" <br />3" <br />4" <br />3" <br />WC <br />2" <br />CW <br />TUB <br />3" <br />2" <br />LAV <br />KS <br />2" <br />2" <br />3" <br />3" <br />2" <br />2" <br />2" <br />4" <br />3" <br />WC <br />2" <br />CW <br />TUB <br />2" <br />LAV <br />KS <br />2" <br />2" <br />3" <br />3" <br />2" <br />2" <br />2" <br />3" <br />3" <br />2" <br />2" <br />2" <br />3" <br />3"FUTURE <br />FUTURE <br />FUTURE <br />FUTURE <br />FUTURE <br />FUTURE <br />FUTURE <br />FUTURE <br />FUTURE <br />FUTURE <br />FUTURE <br />FUTURE <br />FUTURE <br />FUTURE <br />FUTURE <br />SOVENT CONNECTION DETAILSSovent Fixture Branches <br />Sovent Stack Offsetting <br />Combining Sovent Stacks <br />Horizontal Length of Pressure Relief Line <br />Stack Offsets Above Highest Fixture <br />Fixture Distances From Sovent Stack <br />Sovent Waste Branches <br />4"C.I. Deaerator Dimensions <br />Tite Ruff 3"PRL with <br />SE Aerator Sizes <br />* Consult Factory For Penetration Applications <br />SE C.I. Aerator Rough-in Dimensions <br />TM <br />NOT TO SCALENOT TO SCALE <br />NOT TO SCALE <br />NOT TO SCALE <br />NOT TO SCALE <br />NOT TO SCALE <br />NOT TO SCALE <br />NOT TO SCALE <br />SE Sovent / Tite-Ruff <br />Specifications <br /> General: <br /> Provide SE Sovent (SESCO ) Tite-Ruff Aerators, Deaerators and related <br /> components as distributed by Walter Cornwall, Inc. (954) 785-0508. Install <br /> system in compliance with the plumbing construction documents, <br /> installation details and recommendations in the SE Sovent (SESCO) <br /> Design manual 101/o (or latest edition). Follow all recommendations regarding <br /> the use of 1.28GPF Water closets and clothes washer applications. <br /> Materials: <br /> Aerator and Deaerator fittings shall be made in compliance with standard <br /> ASME/ANSI B16.45. Fittings shall be manufactured with the "Dismatic" <br /> method of casting production. Fittings shall be gray cast iron of chemical <br /> composition in accord with ASTM-126 and CISPI 301-82 for hubless pipe <br /> and fittings. <br /> Installation: <br /> Install SE Sovent (SESCO ) Tite-Ruff system in accordance to Design <br /> manual 101/o and follow piping recommendations for 1.6 GPF water closets <br /> and cloths washing machine wastes. See other specification section for <br /> supports, hangers, fire rated pipe penetrations and related DWV <br /> requirements. <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2015 <br />NOT FOR <br />CONSTRUCTION <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />Job No.: <br />Contact: <br />www.glumac.com <br />18200 Von Karman Ave., Suite 100 <br />Irvine, CA 92612 <br />T. 949.833.8190 <br />6/12/2024 7:40:15 PM <br />BIM 360://007.3757.000 - Caribou Industries - 3rd & Broadway/3RD-B_MEP_WEST_R20.rvt <br />R1-P9.7 <br />PLUMBING DETAILS - SOVENT <br />SYSTEM <br />21US00608 <br />3rd & Broadway West <br />1103 North Broadway <br />Santa Ana, CA 92701 <br />21US00608 <br />Checker <br />1 9/21/2021 REISSUE FOR PLAN CHECK <br />2 01/18/2022 REISSUE FOR PLAN CHECK <br />4 06/17/2024 REVISION TO PERMIT <br />(FOR REFERENCE ONLY) <br />EOR: SEAN AGUON <br />LIC#: M41274 <br />10/11/2024