My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
301 N Broadway - Apt TI - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Broadway
>
301 N Broadway
>
301 N Broadway - Apt TI - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:47 AM
Creation date
2/13/2026 5:00:39 AM
Metadata
Fields
Template:
Plan
Permit Number
101120329
Full Address
301 N Broadway
Street Number
301
Street Direction
N
Street Name
Broadway
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
167
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DYH <br />LIMIT OF PODIUM LIMIT OF PODIUM <br />LIMIT OF PODIUM <br />? <br />FOR REFERENCE <br />ONLY <br />PROPERTY LINE <br />PROPERTY LINE <br />PROPERTY LINE <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />N. <br /> <br />B <br />R <br />O <br />A <br />D <br />W <br />A <br />Y <br /> <br />W. 3RD STREET <br />N. <br />S <br />Y <br />C <br />A <br />M <br />O <br />R <br />E <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />(E) BLDG <br />N.I.C. <br />(E) BLDG <br />N.I.C. <br />PROPERTY LINE <br />PROPERTY LINEPROPERTY LINE <br />LINE USED TO MEASURE FIRE <br />SEPARATION DISTANCE. SEE <br />BUILDING ADJACENCY ANALYSIS <br />LETTER ON SHEET LS1.002 <br />LINE USED TO MEASURE FIRE <br />SEPARATION DISTANCE. SEE <br />BUILDING ADJACENCY ANALYSIS <br />LETTER ON SHEET LS1.002 <br />MAXIMUM EXISTING EXTERIOR <br />WALKWAY LOCATION <br />LINE USED TO MEASURE FIRE <br />SEPARATION DISTANCE. SEE <br />BUILDING ADJACENCY ANALYSIS <br />LETTER ON SHEET LS1.002 <br />MAXIMUM EXISTING EXTERIOR <br />WALKWAY LOCATION <br />10' NO BUILD ZONE15' NO BUILD ZONE <br />5' - 6" <br />10' - 0''. <br />5' - 6" <br />10' - 0''. <br />30' - 4" <br />30' - 5" <br />31 <br />' <br /> <br />- <br /> <br />0 <br />" <br />21' - 2" <br />CENTERLINE OF STREET CENTERLINE OF STREETCENTERLINE OF STREET <br />7" <br />8" <br />7" <br />FOR REFERENCE ONLY -REFER TO PERMIT: B-101107992, B-101107990, B-101107993 <br />15 <br />' <br /> <br />- <br /> <br />0 <br />" <br />SHEET NOTES GENERAL NOTES LEGEND <br />NORTH <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2021 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />1/16" = 1'-0" <br />9/23/2024 2:47:10 PM <br />BIM 360://007.3757.000 - Caribou Industries - 3rd & Broadway/3RD-B_INTERIOR_WEST_R20.rvt <br />R2.G2.040 <br />SITE PLAN - OVERALL <br />07.3897.000 <br />3rd & Broadway Interior <br />301 N. Broadway, Santa Ana, CA <br />SCALE:1/16" = 1'-0" <br />SITE PLAN - OVERALL01 <br />N. SITE WORK FOR ACCESSIBILITY WILL BE REVIEWED <br />AND INSPECTED BASED ON AN APPROVED <br />ARCHITECTURAL SITE ACCESSIBILITY PLAN AND <br />NOT THE CIVIL OR LANDSCAPE PLANS. REFER TO <br />PERMIT: B-101107992, B-101107990, B-101107993 <br />FOR THE ASSOCIATED SITE PLANS. <br />K. ILLUMINATION SHALL BE PROVIDED ALONG THE <br />PATH OF TRAVEL FOR THE EXIT DISCHARGE <br />FROM EACH EXIT TO THE PUBLIC WAY. <br />ILLUMINATION LEVEL SHALL BE NOT LESS THAN 1 <br />FOOTCANDLE AT THE WALKING SURFACE UNDER <br />NORMAL POWER AND AN AVERAGE OF NOT LESS <br />THAN 1 FOOTCANDLE AT INITIATION OF <br />EMERGENCY POWER DURATION. <br />L. FLOOR SURFACES SHALL BE SLIP-RESISTANT. <br />M. EXTERIOR LIGHTING, WHERE PROVIDED, SHALL <br />BE OF LOW INTENSITY IN ORDER TO PROVIDE <br />AESTHETICALLY PLEASING LIGHTING WHICH <br />PROMOTE SAFETY, BUT SHALL NOT IMPOSE ON <br />ADJACENT PROPERTIES AND USES. <br />G. ALL PATH OF TRAVEL AREA TO MAINTAIN <br />MAXIMUM RUNNING SLOPE OF 5% AND MAXIMUM <br />CROSS SLOPE OF 2%. <br />H. ALL CURB RAMPS TO MAINTAIN MAXIMUM <br />RUNNING SLOPE OF 8.3% <br />I. ALL ACCESSIBLE STALL LOADING AREA TO <br />MAINTAIN MAXIMUM RUNNING AND CROSS <br />SLOPE OF 2%. <br />A. REFER TO G0 DRAWINGS SERIES FOR SYMBOLS <br />AND ABBREVIATIONS APPLICABLE TO THIS PLAN <br />NOT ALREADY INCLUDED ON THIS SHEET. <br />B. REFER TO G0 DRAWING SERIES FOR ADDITIONAL <br />BUILDING AND CONSTRUCTION SUMMARY AND <br />ANALYSIS. <br />C. REFER TO G0 DRAWING SERIES FOR VEHICLE <br />AND BICYCLE PARKING SUMMARY TABULATION. <br />D. REFER TO OCFA SR#297959 & 297960 FOR FIRE <br />MASTER <br />PLAN. <br />F. REFER TO LIFE SAFETY DRAWING SERIES FOR <br />OCCUPANCY AND EGRESS ANALYSIS. <br />06.13.2022 ISSUE FOR PLAN CHECK <br />A 08.10.2022 REISSUE FOR PLAN CHECK <br />C 06.17.2024 REVISION TO PERMIT <br />11/12/2024
The URL can be used to link to this page
Your browser does not support the video tag.