Laserfiche WebLink
SEE SCHEDULE <br />SEE SCHEDULE SEE SCHEDULE <br />SEE SCHEDULE <br />SEE SCHEDULE <br />SEE SCHEDULE <br />SEE SCHEDULE <br />EQ EQ <br />SEE SCHEDULE <br />SEE SCHEDULE <br />EQ EQ <br />AMENITY <br />LEVEL 6 + 7 <br />A1.2 <br />A1.3 <br />UNIT INTERIOR <br />PANTRY & LINEN & <br />WARDROBE <br />U 3.2 <br />AMENITY <br />LEVEL 6 + 7 <br />G 3.4 <br />UNIT INTERIOR <br />BATHROOM <br />BEDROOM <br />WALK-IN CLOSET <br />U 2.1-2.2 <br />UNIT INTERIOR <br />WASHER & DRYWER CLOSET <br />U 4.2 <br />1. DOOR THRESHOLDS TO BE 1/2" THICK MAXIMUM TYPICAL. A FLOOR OR LANDING SHALL BE NOT MORE THAN 1/2" <br />LOWER THAN THE THRESHOLD OF THE DOORWAY. CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" SHALL BE BEVELED <br />WITH A SLOPE NOT GREATER THAN 1:2. EXCEPT FOR CURBS AT ROOF LEVEL DOORS (RFM). <br />2. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR EFFORT. <br />SURFACE-MOUNTED FLUSH OR SURFACE BOLTS ARE PROHIBITED. AUTOMATIC FLUSH BOLTS ARE ALLOWED ON <br />PAIRS OF DOORS, PROVIDED THE DOOR WITH THE FLUSH BOLT HAS NO KNOBS OR SURFACE-MOUNTED HARDWARE <br />AND THE UNLATCHING OF ANY LEAF REQUIRES ONLY A SINGLE OPERATION. <br />3. DOOR FRAMES AND HARDWARE FOR RATED DOORS SHALL BE LISTED FOR THOSE RATINGS. ALL FIRE RATED DOORS <br />SHALL BE PROVIDED WITH AN AUTOMATIC DOOR CLOSER. SEE SHEET R1.A0.032-.033 FOR REQUIRED FIRE RATINGS <br />FOR DOORS AND SHUTTERS. <br />4. FIRE DOORS SHALL HAVE AN APPROVED LABEL OR EXISTING MARK INDICATING THE FIRE-PROTECTION RATING, <br />WHICH IS PERMANENTLY AFFIXED AT THE FACTORY WHERE FABRICATION AND ASSEMBLY ARE DONE. <br />5. ALL 20-MINUTE RATED ASSEMBLIES SHALL BE PROVIDED WITH APPROVED GASKETING MATERIAL SO INSTALLED TO <br />PROVIDE A SEAL WHERE THE DOOR MEETS THE STOP ON BOTH SIDES AND ACROSS THE TOP. THE DOOR AND FRAME <br />SHALL BEAR AN APPROVAL LABEL OR OTHER IDENTIFICATION SHOWING THE RATING THEREOF, FOLLOWED BY THE <br />LETTER "S". <br />6. FIRE-RATED DOOR FRAMES SHALL BE INSTALLED STRICTLY PER MANUFACTURER'S PRINTED INSTRUCTIONS. <br />MANUFACTURER'S PRINTED INSTRUCTIONS SHALL BE MADE AVAILABLE TO THE INSPECTING AUTHORITIES. <br />7. FURNISH DOOR STOPS FOR ALL DOOR LEAFS. IN EVENT SCHEDULED WALL OR FLOOR BUMPER CANNOT BE USED <br />EFFECTIVELY, FURNISH OVERHEAD STAY. <br />8. PROVIDE DOOR HINGES FOR: <br />A. DOORS OVER 60 INCHES OR LESS = 2 BUTTS <br />B. DOORS OVER 60 INCHES AND NOT OVER 90 INCHES = 3 BUTTS (86 INCHES FOR FIRE-RATED DOORS). <br />C. DOORS OVER 90 INCHES AND NOT OVER 120 INCHES (116 INCHES FOR FIRE-RATED DOORS) = 4BUTTS <br />9. PROVIDE WEATHERSTRIPPING AND SEALS FOR EXTERIOR DOORS AT JAMBS, HEAD AND DOOR BOTTOM. <br />10.DOOR THICKNESS SHALL BE 1 3/4" TYP. U.N.O. <br />11.DOORS INSTALLED IN SMOKE AND FIRE SEPARATIONS SHALL BE AUTOMATIC BY THE ACTUATION OF SMOKE <br />DETECTORS INSTALLED BY APPLICABLE CODES OR BY LOSS OF POWER TO THE SMOKE DETECTOR OR HOLD-OPEN <br />DEVICE. <br />12. DOOR FRAMES SHALL BE HOLLOW METAL, U.N.O. <br />13.ALL DOORS INTO WASHROOMS AND JANITOR CLOSETS SHALL HAVE 2" WIDE STONE THRESHOLDS WITH BEVELED <br />EDGES. COLOR T.B.D. BY ARCHITECT. <br />14.CONTRACTOR TO COORDINATE DOOR HARDWARE AND HARDWARE COUNT TYPICAL. ANY NON-COMPATIBLE <br />HARDWARE IN THE SAME HARDWARE GROUP TO BE BROUGHT IMMEDIATELY TO THE ARCHITECT'S ATTENTION. <br />15.HARDWARE SCHEDULE IS A GUIDE ONLY. FURNISH ALL HARDWARE AS REQUIRED FOR THE PROJECT. HARDWARE <br />REQUIRED FOR ANY PARTICULAR LOCATION, BUT NOT SPECIFIED SHALL BE THE SAME AS THAT SPECIFIED FOR SIMILAR <br />LOCATIONS. ALL DOORS SHALL BE COVERED BY A LISTING OF HARDWARE IN THE FINISH HARDWARE SCHEDULE <br />WHETHER SPECIFIED OR NOT. <br />16.REFER TO DRAWINGS FOR LOCATION OF SANITARY FACILITY SIGNAGE TYPICAL. <br />17.REFER TO DRAWINGS FOR REQUIRED CLEARANCES AT DOOR SWINGS TYPICAL. ANY DISCREPANCIES BETWEEN THE <br />FLOOR PLANS AND THE DETAILS SHOULD BE BROUGHT TO THE ARCHITECT'S ATTENTION PRIOR TO THE START OF WORK. <br />18.CONTRACTOR TO VERIFY & COORDINATE ROUGH OPENING DIMENSIONS IN CONCRETE AND CMU WALLS IN THE FIELD <br />PRIOR TO DOOR FABRICATION. <br />19.PROVIDE NO PAINTED OR PRIMED-FOR-PAINT HINGES. ALL HINGES TO BE FACTORY FINISHED. PROVIDE BRUSHED SS <br />FINISH AT EXTERIOR DOORS AND EQUAL CHROME FINISH AT INTERIOR DOORS TYPICAL. <br />20.SEE MECHANICAL DRAWINGS FOR REQUIRED DOOR UNDERCUTS TYPICAL. INDICATE ON SHOP DRAWINGS. DO NOT <br />USE TRANSFER GRILLES AT DOORS UNLESS APPROVED BY THE ARCHITECT. <br />21. ALL TRANSFORMERS REQUIRED FOR ELECTRIFIED HARDWARE TO BE CONCEALED BEHIND FLUSH ACCESS PANELS <br />TYPICAL. CONTRACTOR TO INDICATE ON SHOP DRAWINGS ACCESS PANEL LOCATIONS FOR ARCHITECT'S REVIEW. <br />ELECTRICAL CONTRACTOR TO COORDINATE REQUIREMENTS WITH SECURITY AND DOOR HARDWARE CONTRACTORS <br />PRIOR TO INSTALLATION. <br />22.THE FORCE FOR PUSHING OR PULLING OPEN INTERIOR SWINGING EGRESS DOORS, OTHER THAN FIRE DOORS, SHALL <br />NOT EXCEED 5 POUNDS. FOR OTHER SWINGING DOORS, AS WELL AS SLIDING AND FOLDING DOORS, THE DOOR LATCH <br />SHALL RELEASE WHEN SUBJECTED TO A 15 POUND FORCE. THE DOOR SHALL BE SET IN MOTION WHEN SUBJECTED TO <br />A 30 POUND FORCE. THE DOOR SHALL SWING INTO A FULL-OPEN POSITION WHEN SUBJECTED TO A 15 POUND FORCE. <br />23.EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING 50 OR MORE PERSONS AND IN ANY <br />HAZARDOUS AREA. <br />24.PROVIDE SAMPLES UPON REQUEST. <br />25.CONTRACTOR TO PROVIDE ELECTRIFIED HARDWARE AND DEVICES AS REQUIRED TO COMPLETE THE SECURITY <br />SYSTEM AND POWER OPERATED DEVICE INSTALLATION. CONTRACTOR TO PROVIDE AND COORDINATE ACCESS PANELS <br />REQUIRED FOR ELECTRIFIED HARDWARE OR SECURITY DEVICES. CONTRACTOR TO PROVIDE LAYOUT PLANS FOR <br />ARCHITECT'S REVIEW. <br />26.FOR EXTERIOR DOORS THAT ARE PART OF A CURTAINWALL SYSTEM ALL WIRING FOR ELECTRIFIED AND SECURITY <br />DEVICES TO BE CONCEALED WITHIN THE MULLIONS TYPICAL. <br />27.PANIC DEVICES TO BE PROVIDED AS REQUIRED TO MEET APPLICABLE CODES. <br />28.SMOKE SEALS TO BE PROVIDED PER APPLICABLE CODES. <br />29.DOORS SCHEDULED AS SMOKE DOORS TO BE DOOR HARDWARE + GASKET ASSEMBLIES MEETING THE TESTING <br />CRITERIA OF UL 1784 & NFPA 105 <br />30.ALL DOOR SIZES SHOWN ON THE DOOR SCHEDULE ARE OPENING SIZES. PROVIDE ALLOWANCE FOR THRESHOLDS, <br />FRAMES, ETC. <br />31.ALL DOORS AND FRAMES SHALL BE REINFORCED FOR CLOSERS, STOPS AND HARDWARE. <br />32.ALL FIRE RATED DOORS SHALL BE GASKETED AT HEAD AND JAMBS. <br />33.CONTRACTOR SHALL VERIFY ALL CONCRETE AND MASONRY OPENINGS IN THE FIELD PRIOR TO THE FABRICATION OF <br />DOORS AND FRAMES. <br />34.ALL LEGAL EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL <br />KNOWLEDGE OR EFFORT AND SHALL SWING IN THE DIRECTION OF EGRESS. SPECIAL LOCKING DEVICES SHALL BE AN <br />APPROVED TYPE. <br />35.AIR LEAKAGE AT EXTERIOR DOORS SHALL BE LIMITED PER THE FOLLOWING: <br />A. ALL DOORS SHALL BE PROVIDED WITH A SEAL, ASTRAGAL OR BAFFLE AT THE HEAD, SILL, AND JAMBS. <br />B. DOORS REQUIRING VERTICAL OR HORIZONTAL TRACK AND GUIDES SHALL USE A CONTINUOUS MOUNTING ANGLE, <br />SEALED IN ACCORDANCE WITH ITEM "e" LISTED HERE. <br />C. MEETING RAILS OF SECTIONAL DOORS AND MEETING STILES OR RAILS OF BI-PARTING DOORS SHALL BE PROVIDED <br />WITH A SEAL, ASTRAGAL OR BAFFLE. <br />D. SWINGING AND REVOLVING DOORS SHALL BE WEATHER-STRIPPED AT THE HEAD, SILL AND JAMBS. <br />36.ALL FIRE RATED DOORS WHICH OPEN INTO EXIT ENCLOSURES OR EXIT PASSAGEWAYS SHALL BEAR MANUFACTURES <br />LABEL INDICATING A MAXIMUM 450 DEGREE F TEMPERATURE RISE ON THE EXPOSED SIDE. <br />37.GLAZING WITHIN DOORS AND SIDELIGHTS WITHIN 24" SHALL COMPLY WITH CBC SECTION 2406. <br />38.NOT USED <br />39. ALL PIN-TYPE DOOR HINGES ACCESSIBLE FROM OUTSIDE SHALL HAVE NON-REMOVABLE HINGE PINS. HINGES SHALL <br />HAVE MIN. 1/4" DIA. STEEL JAMB STUD WITH 1/4" MIN. PROTECTION. THE STRIKE PLATE FOR LATCHES AND HOLDING DEVICE <br />FOR PROJECTING DEADBOLTS IN WOOD CONSTRUCTION SHALL BE SECURED TO THE JAMB AND THE WALL FRAMING <br />WITH SCREWS NO LESS THAN 2-1/2" LONG. <br />40.CYLINDER GUARDS SHALL BE INSTALLED ON ALL CYLINDER LOCKS WHENEVER THE CYLINDER PROJECTS BEYOND THE <br />FACE OF THE DOOR OR IS OTHERWISE ACCESSIBLE TO GRIPPING TOOLS. <br />41.DEADBOLTS SHALL HAVE HARDENED INSERTS. DEADLOCKING LATCH WITH KEY-OPERATED LOCKS SHALL BE PROVIDED <br />ON EXTERIOR. LOCKS SHALL BE OPENABLE WITHOUT KEY, SPECIAL KNOWLEDGE, OR SPECIAL EFFORT FROM THE <br />INTERIOR. <br />42.STRAIGHT DEADBOLTS SHALL HAVE A MIN. THROW OF 1" AND AN EMBEDMENT OF NOT LESS THAN 5/8", AND A HOOK- <br />SHAPED OR AN EXPANDING-LUG DEADBOLT SHALL HAVE A MINIMUM THROW OF 3/4" . <br />43.LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE <br />OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS OR OTHER <br />HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. <br />44.THE BOTTOM 10" OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING DOORS SHALL HAVE A SMOOTH UNINTERRUPTED <br />SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS <br />CONDITION. WHERE NARROW FRAME DOORS ARE USED, A 10" HIGH SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH <br />SIDE OF THE DOOR, WHICH WILL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A <br />TRAP OR HAZARDOUS CONDITION. <br />45.DOORS OPENING INTO REQUIRED 1-HOUR FIRE-RESISTIVE CORRIDORS SHALL BE PROTECTED WITH A SMOKE OR <br />DRAFT-STOP FIRE ASSEMBLY HAVING A 20-MINUTE RATING, AND SHALL BE SELF CLOSING. <br />46.ALL EGRESS DOOR OPERATION SHALL ALSO COMPLY WITH CBC SECTION 1008.1.9-1008.1.9.7. <br />47. G.C. TO PROVIDE COMPLETE DOOR/HARDWARE PACKAGE TO FUNCTION AS INDICATED. ALL DOORS AND HARDWARE <br />SHALL BE BUILDING STANDARD, U.O.N. SUBMIT COMPLETE SPECS TO ARCHITECT FOR REVIEW AND APPROVAL. <br />48. ALL HARDWARE TO MEET TITLE 24 AND ACCESSIBILITY REQUIREMENTS. SEE MOUNTING HEIGHTS ON SHEET R1.G0.032 <br />49. THE BOTTOM 10" OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE <br />TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS <br />CONDITION (CBC SEC. 11B-404.2.10) <br />50. ALL GLAZING SHALL BE TEMPERED, ALL EXPOSED EDGES SHALL BE POLISHED. GLAZING WITHIN A 24" ARC OF EITHER <br />SIDE OF DOORS MUST BE OF SAFETY GLAZING MATERIAL (CBC SEC. 2406). <br />51. HAND-ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 34" AND 44" A.F.F. (CBC SEC. 11B-404.2.7 ) <br />LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND ARE IN THE PATH OF TRAVEL SHALL BE OPERABLE WITH <br />A SINGLE EFFORT BY LEVER-TYPE HARDWARE, PANIC BARS OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE <br />WITHOUT REQUIRING THE ABILITY TO GRASP THE HARDWARE. (CBC SEC. 11B-309.4). <br />ABREVIATIONS LIST: <br />AL = ALUMINUM <br />BRZ = OIL RUBBED BRONZE <br />BS = BLDG STANDARD <br />CL = CLEAR <br />(E) = EXISTING <br />FH = FULL HEIGHT <br />FR = FIRE RATED <br />HC = HOLLOW CORE <br />HM =HOLLOW METAL <br />INT = BY INTERIOR DOCUMENTS <br />NR =NON FIRE RATED <br />PG =PAINT GRADE <br />PT = PAINT <br />SC = SOLID CORE <br />SS = STAINLESS STEEL <br />ST = STAIN <br />WD = WOOD <br />SHEET NOTES <br />LEGEND <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2022 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />1/4" = 1'-0" <br />9/23/2024 2:47:22 PM <br />BIM 360://007.3757.000 - Caribou Industries - 3rd & Broadway/3RD-B_INTERIOR_WEST_R20.rvt <br />R2.I0.031 <br />DOOR TYPES & SCHEDULE <br />07.3897.000 <br />3rd & Broadway Interior <br />301 N. Broadway, Santa Ana, CA <br />06.13.2022 ISSUE FOR PLAN CHECK <br />A 08.10.2022 REISSUE FOR PLAN CHECK <br />C 06.17.2024 REVISION TO PERMIT <br />D 09.27.2024 REISSUE FOR PLAN CHECK <br />SCALE:1/4" = 1'-0" <br />DOOR TYPES <br />SCALE:1/4" = 1'-0" <br />DOOR NOTES <br />G3.4 - - 3' - 6" 8' - 0" 0' - 0 1/2" GL GL - - NON-RATED PIVOT HINGE WITH HOLD OPEN <br />A1.3 3' - 4" 7' - 2" 3' - 0" 8' - 0" 0' - 1 3/4" HM PT HM PT NON-RATED STORAGE LOCKSET <br />A1.2 3' - 4" 7' - 2" 3' - 0" 8' - 0" 0' - 1 3/4" HM PT HM PT NON-RATED PRIVACY LOCKSET <br />U 4.2 - - 1' - 2" 7' - 0" 0' - 1 3/4" WD PT - - NON-RATED BI-FOLDING DOOR PULL <br />U 3.2 - - 1' - 8" 7' - 0" 0' - 1 3/4" WD PT - - NON-RATED BI-FOLDING DOOR PULL <br />U 2.2 3' - 2" 7' - 2" 2' - 10" 7' - 0" 0' - 1 3/4" WD PT HM PT NON-RATED PASSAGE LATCH <br />U 2.1 3' - 2" 7' - 2" 2' - 10" 7' - 0" 0' - 1 3/4" WD PT HM PT NON-RATED PRIVACY LOCKSET <br />WIDTH HEIGHT WIDTH HEIGHT THICK MATERIAL FINISH MATERIAL FINISH <br />DIMENSIONS DIMENSIONS DIMENSIONS DIMENSIONS DIMENSIONSTYPE <br />FRAME FRAME DOOR DOOR PANEL DOOR PANEL DOOR FRAME FIRE RATING HARDWARE SET <br />DOOR SCHEDULE <br />D <br />11/12/2024