Laserfiche WebLink
R2.I5.312 3 <br />4 <br />5 <br />6 <br />U2.1 <br />A3 <br />U <br />A3U <br />D3 <br />U <br />A3U- <br />10 <br />' <br /> <br />- <br /> <br />5 <br />" <br />7' - 6"11" <br />7' <br /> <br />- <br /> <br />6 <br />" <br />2' <br /> <br />- <br /> <br />1 <br />1 <br />" <br />D3 <br />U <br />1' - 9" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />02 <br />BATHROOM -B <br />TL10TL-10 <br />PT-10 <br />9 <br />R2.I0.034 <br />________________ <br />08 <br />R2.I6.401 <br />________________12 <br />R2.I6.401 <br />________________ <br />BATHROOM -B <br />TL-10 <br />PT-10 <br />6" MIN.6" MIN.6' - 6" (48" MIN.) <br />6" <br /> <br />M <br />I <br />N <br />. <br />3' <br />- <br />2 <br />" <br /> <br />M <br />A <br />X <br />. <br />6' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />. <br />11 <br />10 <br />TL10 <br />TL-10 <br />PT-10 PT10 <br />TL10 <br />6' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />. <br />2'-0" MIN. <br />EQ.EQ. <br />2' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />3'-4" MIN. <br />2' <br />- <br />8 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />6 <br />" <br />08 <br />10 <br />01 <br />R2.I6.500 <br />________________ <br />PT10 <br />TL10 <br />2' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />TL-10 <br />PT-10 <br />PT10 <br />TL10 <br />2' <br />- <br />8 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />6 <br />" <br />3' <br /> <br />- <br /> <br />4 <br />" <br />2'-0" MIN. <br />6' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />. <br />10 <br />A. REFER TO R2.I0.050 FOR ALL PARTITION TYPE <br />DETAILS <br />B. REFER TO R2.I0.060 FOR ALL FINISHES, <br />EQUIPMENT AND TOILET ACCESSORIES. <br />C. DIMENSIONS OF WALL PARTITIONS ARE TO <br />WALL FINISH UNLESS NOTED OTHERWISE <br />D. DIMENSIONS ARE MEASURED FROM CENTER <br />LINE OF EQUIPMENT/LIGHT SWITCHES/LIGHT <br />FIXTURES, TYPICAL UNLESS NOTED OTHERWISE <br />E. GYPSUM BOARD CEILING PAINT FINISH SHALL <br />BE LEVEL 4 WHERE OCCURS UNLESS NOTED <br />OTHERWISE <br />F. LOCATE LIGHTS IN CENTER OF PATHWAY OR <br />CENTER OF CEILING TILE UNLESS NOTED <br />OTHERWISE <br />G. REFER TO THE DOOR SCHEDULE IN THE CORE <br />AND SHELL DOCUMENT FOR ALL UNTAGGED <br />DOORS, EXCEPT THOSE LOCATED INSIDE THE <br />UNIT, WHICH SHOULD BE REFERENCED IN THE <br />ENLARGED UNIT PLAN WITHIN THIS INTERIOR TI <br />DOCUMENT. <br />D <br />SHEET NOTES <br />GENERAL NOTES <br />Ref North <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2022 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />As indicated <br />9/23/2024 2:52:37 PM <br />BIM 360://007.3757.000 - Caribou Industries - 3rd & Broadway/3RD-B_INTERIOR_WEST_R20.rvt <br />R2.I5.312 <br />2BR_2 - ENLARGED PLANS - <br />BATHROOM <br />07.3897.000 <br />3rd & Broadway Interior <br />301 N. Broadway, Santa Ana, CASCALE:1/2" = 1'-0" <br />2BR_2 - CONSTRUCTION PLAN - BATH-B1 <br />SCALE:1/2" = 1'-0" <br />2BR_2 - FINISH PLAN - BATH-B2 <br />SCALE:1/2" = 1'-0" <br />INTERIOR ELEVATION 2 - 2BR_2 - BATH-B4 <br />SCALE:1/2" = 1'-0" <br />INTERIOR ELEVATION 1 - 2BR_2 - BATH-B3 <br />SCALE:1/2" = 1'-0" <br />INTERIOR ELEVATION 3 - 2BR_2 - BATH-B5 <br />SCALE:1/2" = 1'-0" <br />INTERIOR ELEVATION 4 - 2BR_2 - BATH-B6 <br />02 CABINETS BENEATH TO BE REMOVED WHEN <br />ACCESSIBILITY IS REQUIRED. <br />08 INCLUDE REINFORCING PROVISIONS FOR <br />FOLDAWAY SIDE GRAB BAR <br />10 AREA OF REINFORCING FOR GRAB BAR. <br />11 SHOWER ROD AND CURTAIN. <br />C 06.17.2024 REVISION TO PERMIT <br />D 09.27.2024 REISSUE FOR PLAN CHECK <br />C <br />NOTE: NUMBER OF COMPLYING BATHROOMS (BATHROOM 'B') <br />PER OPTION 2 (CBC 1134A.2). <br />11/12/2024