Laserfiche WebLink
REFER TO RCP <br />09 22 16.C05 <br />GRID SUSPENSION SYSTEM <br />09 29 00.B05 <br />SAG-RESIS GYP BD <br />09 29 00.J05 <br />CONTROL JOINT <br />ALIGN <br />1/4" <br />09 22 16.C02 <br />HANGER <br />SCHEDULED ACOUSTICAL <br />DRYWALL CEILING WITH <br />SPRAY-APPLIED FINISH <br />NOTE: PROVIDE CONTROL JOINTS AT CEILINGS THAT EXCEEDS 30 FEET WITHOUT PERIMETER <br />RELIEF OR EXCEED 50 FEET WITH PERIMETER RELIEF. COORDINATE LOCATION WITH ARCHTECT <br />09 51 13.C02 <br />2" X 2" ANGLE MOLDING <br />09 29 00.B05 <br />SAG-RESIS GYP BD <br />09 29 00.J10 <br />J-BEAD <br />VARIES <br />09 22 16.C01 <br />WIRE TIE <br />09 51 13.B00 <br />SUSPENSION SYSTEM <br />SCHEDULED OR EXISTING <br />PARTITION <br />VARIES <br />8" MAX <br />REFER TO RCP <br />RETURN AIR SLOT; REFER <br />TO ENGINEERING DRAWINGS <br />METAL ANGLE TO BE <br />PAINTED MATTE BLACK <br />SCHEDULED ACOUSTICAL <br />DRYWALL CEILING WITH <br />SPRAY-APPLIED FINISH <br />VARIES <br />CHANNEL BRIDGING <br />09 22 16.A09 <br />2" <br />SAG-RESIS GYP BD <br />09 29 00.B05 <br />J-BEAD <br />09 29 00.J10 <br />XX REFER TO CONSTRUCTION PLAN <br />WIRE TIE <br />09 22 16.C01 <br />SUSPENSION SYSTEM <br />09 51 13.B00 <br />SAG-RESIS GYP BD <br />09 29 00.B05 <br />WIRE TIE <br />09 22 16.C01 <br />SUSPENSION SYSTEM <br />09 51 13.B00 <br />VARIES <br />XX REFER TO CONSTRUCTION PLAN <br />8" <br />ALIG <br />N <br />METAL STUD <br />09 22 16.A00 <br />METAL RUNNER TRACK <br />09 22 16.A01 <br />JOINT REINFORCEMENT <br />09 29 00.J09 <br />GYP BD 5/8" <br />09 29 00.A01 <br />GYP BD 5/8" <br />09 29 00.A01 <br />SUSPENSION SYSTEM <br />09 51 13.B00 <br />ACOUSTICAL PANEL CEILING <br />09 51 13.A00 <br />EDGE MOLDING <br />09 51 13.C00 <br />CORNER BEAD <br />09 29 00.J01 <br />6" <br />ALIG <br />N <br />CHANNEL BRIDGING <br />09 22 16.A09 <br />SUSPENSION SYSTEM <br />09 51 13.B00 <br />ACOUSTICAL PANEL CEILING <br />09 51 13.A00 <br />EDGE MOLDING <br />09 51 13.C00 <br />CORNER BEAD <br />09 29 00.J01 <br />SAG-RESIS GYP BD <br />09 29 00.B05 <br />HANGER ROD <br />09 51 13.G01 <br />REFER TO RCP <br />LINEAR LIGHT FIXTURE <br />REFER TO ELEC'L. DWGS. <br />5/8" TYPE X GYP BD CEILING ON <br />3 5/8" METAL STUDS AT 16" O.C. <br />2" <br />9" <br />5/8" TYPE X GYP BD CEILING ON <br />3 5/8" METAL STUDS AT 16" O.C. <br />EXPOSED PAINTED CONCRETE <br />FLOOR SLAB <br />4" <br />1' - 0" MAX. <br />REFER TO RCP <br />AS INDICATED ON INT. ELEV. <br />12 GA. METAL STUD AT 12" <br />O.C. (OPTION TO PROVIDE <br />HSS INSERTED THROUGH <br />THE WALL) <br />3/4" THK. SOLID WOOD <br />LEDGE WHERE <br />OCCURS <br />LIGHT FIXTURE <br />REFER TO <br />ELECT'L. DWGS. <br />FACE OF RATED WALL <br />REFER TO RCP <br />GYP. BD. ON 2 <br />1/2" METAL <br />STUDS AT 16" <br />O.C. <br />CONT. SEALANT <br />EXPOSED <br />CONCRETE <br />C.T. IN THINSET ON W.R. GYP. <br />BD. ON 2 1/2" METAL STUD AT <br />16" O.C. FURRED OUT WALL <br />9" <br />VARIES WHERE IT OCCURS <br />TYP. 1' - 0" <br />DOWN LIGHT <br />FIXTURES <br />LIGHT FIXTURE REFER <br />TO ELECT'L. DWGS. <br />FACE OF STRUCTURE <br />WALL <br />5/8" THK. TYPE 'X' <br />GYP. BD. ON 2 1/2" <br />METAL STUDS AT <br />16" O.C. <br />CONT. SEALANT <br />CEILING FINISH <br />WHERE OCCURS <br />PER RCP <br />9" <br />REFER TO RCP <br />CONT. GYP. BD. <br />CASING EDGE <br />FINISH FLOOR <br />1 1/2" <br />AS INDICATED ON INTERIOR ELEVATIONS <br />HILTI X-ZF .138 DIAMETER X <br />3/4" LONG LOW VELOCITY <br />POWDER ACTUATED DRIVE <br />FASTENERS AT 24" O.C., ICC- <br />ED, ESR 1663. <br />F.R. PLYWOOD <br />VARIES 8" <br />METAL STUD <br />09 22 16.A00 <br />METAL RUNNER TRACK <br />09 22 16.A01 <br />JOINT REINFORCEMENT <br />09 29 00.J09 <br />GYP BD 5/8" <br />09 29 00.A01 <br />GYP BD 5/8" <br />09 29 00.A01 <br />SUSPENSION SYSTEM <br />09 51 13.B00 <br />ACOUSTICAL PANEL CEILING <br />09 51 13.A00 <br />EDGE MOLDING <br />09 51 13.C00 <br />CORNER BEAD <br />09 29 00.J01 <br />6" <br />SCHEDULED PARTITION <br />REFER TO RCP <br />2 1/2" METAL STUDS <br />AT 16" O.C. <br />LINEAR LIGHT FIXTURE <br />REFER TO ELEC'L. DWGS. <br />6" <br />4" <br />5/8" TYPE X GYP BD CEILING ON <br />3 5/8" METAL STUDS AT 16" O.C. <br />SHEET NOTES <br />GENERAL NOTES <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2022 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />As indicated <br />9/23/2024 2:54:02 PM <br />BIM 360://007.3757.000 - Caribou Industries - 3rd & Broadway/3RD-B_INTERIOR_WEST_R20.rvt <br />R2.I6.301 <br />CEILING DETAILS <br />07.3897.000 <br />3rd & Broadway Interior <br />301 N. Broadway, Santa Ana, CA <br />SCALE:3" = 1'-0" <br />TYP GYP BD CLG CONTROL JOINT01 <br />SCALE:3" = 1'-0" <br />GYP BD RETURN AIR SLOT02 <br />SCALE:3" = 1'-0" <br />RETURN AIR SLOT W GYP BD03 <br />SCALE:3" = 1'-0" <br />FLOW BAR DIFFUSER @ Gyp Bd04 <br />SCALE:3" = 1'-0" <br />CEILING SOFFIT / FASCIA 105 <br />SCALE:3" = 1'-0" <br />CEILING TRANSITION 306 <br />06.13.2022 ISSUE FOR PLAN CHECK <br />A 08.10.2022 REISSUE FOR PLAN CHECK <br />C 06.17.2024 REVISION TO PERMIT <br />D 09.27.2024 REISSUE FOR PLAN CHECK <br />SCALE:3" = 1'-0" <br />TYP. CEILING COVE LIGHT07 <br />SCALE:1 1/2" = 1'-0" <br />FLOATING SHELF AT SOFFIT W/ LIGHT COVE09 <br />SCALE:1 1/2" = 1'-0" <br />TYP. WALL W/ ALCOVE ABOVE LOBBY11 <br />SCALE:3" = 1'-0" <br />CEILING SOFFIT / ACT08 <br />C <br />C <br />SCALE:3" = 1'-0" <br />CEILING COVE LIGHT10 <br />C <br />C <br />11/12/2024