Laserfiche WebLink
Cantilevered Retaining Wall <br />LIC# : KW-06019219, Build:20.23.10.02 HUSAM GHANIM (c) ENERCALC INC 1983-2023 <br />DESCRIPTION:9'-0" Freestanding CMU Wall (Wind Loading) <br />Ghanim Structural Engineering <br />898 N. Fair Oaks Ave <br />Suite F <br />Pasadena, CA 91103 <br />(323) 494-3208 <br />www.ghanimse.com <br />Project File: Freesntanding Wall Design.ec6 <br />Project Title:SoCal Gas <br />Engineer:IG <br />Project ID:25-078 <br />Project Descr:Site Walls <br />Rebar Lap & Embedment Lengths Information <br />Stem Design Segment: Bottom <br />Stem Design Height: 0.00 ft above top of footing <br />K_cover=7.375, K_spacing=16, K_diam=4.5, and K_min=4.5 <br />Lap Splice length for #4 bar specified in this stem design segment (25.4.2.4a) =20.00 in <br />Development length for #4 bar specified in this stem design segment =12.00 in <br />Hooked embedment length into footing for #4 bar specified in this stem design segment =5.63 in <br />As Provided =0.1500 in2/ft <br />As Required =0.0496 in2/ft <br />10