My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2923 W Raymar St #2 - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Raymar St
>
2923 W Raymar St Unit# 2
>
2923 W Raymar St #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:39 AM
Creation date
2/13/2026 5:00:40 AM
Metadata
Fields
Template:
Plan
Permit Number
101121768
Full Address
2923 W Raymar St Unit# 2
Street Number
2923
Street Direction
W
Street Name
Raymar
Street Suffix
St
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 330 2022 Building Energy Efficiency Standards <br />Dwelling Unit Floor Area (ft2) <br />>1500 <br />>1000 - 1500 <br />750 - 1000 <br /><750 <br />Table 150.0-G Kitchen Range Hood Airflow Rates (cfm) and ASTM E3087 Capture Efficiency (CE) Ratings <br />According to Dwelling Unit Floor Area and Kitchen Range Fuel Type <br />Hood Over Electric Range <br />50% CE or 110 cfm <br />50% CE or 110 cfm <br />55% CE or 130 cfm <br />65% CE or 160 cfm <br />Hood Over Natural Gas Range <br />70% CE or 180 cfm <br />80% CE or 250 cfm <br />85% CE or 280 cfm <br />85% CE or 280 cfm <br />Table 150.0-H Prescriptive Ventilation System Duct Sizing [ASHRAE 62.2:Table 5-3] <br />Fan Airflow Rating, <br />cfm at minimum static <br />pressuref 0.25 in. water <br />(L/s at minimum 62.5 Pa) <br />Minimum Duct Diameter, <br />in. (mm) a,b For Rigid duct <br />Minimum Duct Diameter, <br />in. (mm) a,b For Flex duct c <br />≤50 <br />(25) <br />4 e <br />(100) <br />4 <br />(100) <br />≤80 <br />(40) <br />5 <br />(125) <br />5 <br />(125) <br />≤100 <br />(50) <br />5 <br />(125) <br />6 <br />(150) <br />≤125 <br />(60) <br />6 <br />(150) <br />6 <br />(150) <br />≤150 <br />(70) <br />6 <br />(150) <br />7 <br />(150) <br />≤175 <br />(85) <br />7 <br />(180) <br />7 <br />(180) <br />≤200 <br />(95) <br />7 <br />(180) <br />8 <br />(205) <br />≤250 <br />(120) <br />8 <br />(205) <br />8 <br />(205) <br />≤350 <br />(165) <br />9 <br />(230) <br />9 <br />(230) <br />≤400 <br />(190) <br />10 <br />(255) <br />10 <br />(255) <br />≤450 <br />(210) <br />10 <br />(255) <br />NP <br />≤700 <br />(330) <br />12 <br />(305) <br />NP <br />≤800 <br />(380) <br />12 d <br />(305) <br />NP <br />Footnotes for Table 150.0-H: <br />a. For noncircular ducts, calculate the diameter as four times the cross-sectional area divided by the perimeter. <br />b. NP = application of the prescriptive table is not permitted for this scenario. <br />c. Use of this table for verification of flex duct systems requires flex duct to be fully extended and any flex duct <br />elbows to have a minimum bend radius to duct diameter ratio of 1.0. <br />d. For this scenario, use of elbows is not permitted. <br />e. For this scenario, 4 in. (100 mm) oval duct shall be permitted, provided the minor axis of the oval is greater <br />than or equal to 3 in. (75 mm) <br />f. When a vented range hood utilizes a capture efficiency rating to demonstrate compliance with 150.0(o)1Giiib, <br />a static pressure greater than or equal to 0.25 in. of water at the rating point shall not be required, and the <br />airflow listed in the approved directory corresponding to the compliant capture efficiency rating point shall be <br />applied to Table 150.0-H for determining compliance. <br />Note: Authority: Sections 25213, 25218, 25218.5, 25402 and 25402.1, Public Resources Code. Reference: Sections <br />25007, 25008, 25218.5, 25310, 25402, 25402.1, 25402.4, 25402.5, 25402.8, and 25943, Public Resources Code. <br />SECTION 150.0 – MANDATORY FEATURES AND DEVICES T-2 <br />Roben Mardirosian, P.E. <br />10540 Jardine Ave. <br />Sunland, CA 91040 <br />Tel: (818) 484-0495 <br />Email: roben@armenengineers.com <br />29 <br />2 <br />3 <br /> <br />W <br />. <br /> <br />R <br />A <br />Y <br />M <br />A <br />R <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br /> ( <br />A <br />D <br />U <br />) <br />TI <br />T <br />L <br />E <br />- <br />2 <br />4 <br /> <br />R <br />E <br />P <br />O <br />R <br />T <br />DATE: 9/13/24 <br />Panasonic Whisper Ceiling Fan FV-0511VQ1 <br />Static Pressure in inches w.g. <br />Air Volume (CFM) <br />Noise (sones) <br />Ventilation Fan <br />Characteristics <br />(HVI Certified data ) <br />Power Consumption (watts) <br />Energy Efficiency (CFM/Watt) <br />Speed (RPM) <br />Current (amps) <br />Power Rating (V/Hz) <br />ENERGY STAR rated <br />0.1 <br />110 <br /><0.3 <br />10.6 <br />10.6 <br />957 <br />0.18 <br />120/60 <br />YES <br />0.25 <br />111 <br />0.9 <br />16.4 <br />6.9 <br />1239 <br />0.26 <br />4" <br />0.1 <br />50 <br /><0.3 <br />4 <br />12.5 <br />756 <br />0.07 <br />120/60 <br />YES <br />0.25 <br />53 <br />0.4 <br />7.2 <br />7.4 <br />1093 <br />0.13 <br />0.1 <br />80 <br /><0.3 <br />5.9 <br />13.6 <br />821 <br />0.11 <br />120/60 <br />YES <br />0.25 <br />83 <br />0.6 <br />10.8 <br />7.7 <br />1172 <br />0.18 <br />4"4" <br />T- <br />U <br />N <br />I <br />T <br /># <br />2