Laserfiche WebLink
DN <br />DN <br />DN <br />D <br />W <br />FEC <br />FEC <br />FECFEC <br />FE <br />C <br />FE <br />- <br />K <br />FE <br />FE <br />FE <br />A <br />A B <br />B C <br />C <br />D <br />D E <br />E <br />F <br />F G <br />G <br />H <br />H <br />J <br />J <br />1 1 <br />2 2 <br />3 3 <br />5 5 <br />6 6 <br />7 7 <br />8 8 <br />9 9 <br />D.8 <br />D.8 <br />F.2 <br />F.2 <br />2.5 2.5 <br />A <br />A B <br />B C <br />C <br />D <br />D E <br />E <br />F <br />F G <br />G <br />H <br />H <br />J <br />J <br />1 1 <br />2 2 <br />2.5 2.5 <br />3 3 <br />4 4 <br />5 5 <br />6 6 <br />7 7 <br />8 8 <br />9 9 <br />D.8 <br />D.8 <br />F.2 <br />F.2 <br />102 <br />GAME <br />ROOM <br />121 <br />BOWLING <br />LANES <br />120 <br />BOWLERS <br />APPROACH <br />119 <br />BOWLERS <br />SEATING <br />122 <br />PINSETTER <br />SERVICE <br />124 <br />CORRIDOR <br />123 <br />ELECTRICAL <br />125 <br />BREAK <br />ROOM <br />126 <br />OFFICE <br />127 <br />SAFE <br />128 <br />MECHANICS <br />129 <br />EXIST. <br />ELEVATOR <br />101 <br />MALL <br />ENTRANCE <br />103 <br />STORAGE <br />103A <br />STORAGE <br />104 <br />JANITOR <br />105 <br />FAMILY <br />RESTROOM <br />109 <br />WOMENS <br />108 <br />MENS <br />116 <br />REDEMPTION <br />ROOM <br />117 <br />PARTY/ <br />GAME <br />KARAOKE <br />118 <br />BOWLING/ <br />GUEST <br />COUNTER <br />115 <br />KITCHEN <br />114 <br />COOLER <br />110 <br />MECH. <br />111 <br />COMM./STORAGE <br />131 <br />BAR <br />SEATING <br />112 <br />BAR <br />113 <br />SNACK <br />BAR <br />135 <br />PARTY <br />ROOM 1 <br />137 <br />VESTIBULE <br />138 <br />PARTY <br />ROOM 2 <br />139 <br />PARTY <br />ROOM 3 <br />136 <br />STORAGE <br />107 <br />STORAGE <br />106 <br />STORAGE <br />130 <br />SIDE <br />AISLE <br />140 <br />STORAGE <br />142 <br />GAME <br />ROOM <br />141 <br />PLUSH <br />STORAGE <br />EP102 <br />1 <br />NEW POWER BUSWAY A (SECTION 1) <br />70'-0" <br />NEW BUS A AND B <br />DISCONNECTS WITH <br />CONTACTORS MTD. ON <br />WALL ABOVE. <br />NEW TRANSFORMERS <br />"T-BUS-A" AND "T-BUS- <br />B" MTD. ABOVE <br />CEILING. <br />80'-0"80'-0" <br />80'-0"80'-0" <br />70'-0" <br />10'-0"10'-0" <br />70'-0" <br />60 <br />' <br />- <br />0 <br />" <br />300' <br />310' <br />NEW POWER BUSWAY A (SECTION 2) <br />NEW POWER BUSWAY A (SECTION 3) <br />NEW POWER BUSWAY A (SECTION 4) <br />NE <br />W <br /> <br />P <br />O <br />W <br />E <br />R <br /> <br />B <br />U <br />S <br />W <br />A <br />Y <br /> <br />B <br /> <br />( <br />S <br />E <br />C <br />T <br />I <br />O <br />N <br /> <br />1 <br />) <br />NEW POWER BUSWAY B (SECTION 2) <br />NEW POWER BUSWAY B <br />(SECTION 3) <br />NEW POWER BUSWAY B <br />(SECTION 4) <br />NEW POWER BUSWAY B (SECTION 5) <br />NEW POWER BUSWAY B (SECTION 6) <br />A <br />A B <br />B C <br />C <br />D <br />D E <br />E <br />F <br />F G <br />G <br />H <br />H <br />J <br />J <br />1 1 <br />2 2 <br />2.5 2.5 <br />3 3 <br />4 4 <br />5 5 <br />6 6 <br />7 7 <br />8 8 <br />9 9 <br />D.8 <br />D.8 <br />F.2 <br />F.2 <br />MD <br />B <br /> <br />( <br />E <br />) <br />GS2 (E) <br />DP <br />L <br />1 <br /> <br />( <br />E <br />) <br />HL (E) <br />LIGHTING CONTROL PANEL "LCP1" (E) <br />LP4 (E) <br />AC (E) <br />LP1 (E) <br />BS (E) <br />GS1 (E) <br />CONT. (E) <br />LP2 (E) <br />LP3 (E) <br />CONT. (E) <br />DLP2A (E) <br />DLP2B (E) <br />DLP2C (E) <br />DLP2D (E) <br />DLP2E (E) <br />7 <br />7 <br />7 <br />7 <br />7 <br />7 <br />7 7 <br />7 <br />7 <br />7 <br />30,45,75 KVA <br />TRANSFORMER <br />STRUCTURE <br />UNISTRUT SPANNING <br />MINIMUM OF (3) JOISTS <br />UNISTRUT CONNECTION AND <br />DOUBLE NUT <br />UNISTRUT CONNECTION WITH <br />WASHER AND DOUBLE NUT <br />EACH SIDE. <br />BOLT TRANSFORMER TO <br />FRAME AT FACTORY <br />RECOMMENDED POINTS WITH <br />VIBRATION PAD. <br />UNISTRUT DOUBLED UP BACK <br />TO BACK <br />5/8" THREADED ROD (TYP.) <br />REFER TO MANUFACTURER <br />INSTALLATION GUIDE ON <br />CLEARANCES FOR <br />VENTALATION AND <br />SEPARATION FROM <br />COMBUSTABLES. <br />WHERE APPLICABLE, <br />ENSURE TRANSFORMER IS <br />ABOVE ACCESSIBLE <br />CEILING. (30 & 45 KVA) <br />CEILING <br />STRUT LATERAL <br />SIESMIC BRACING TO <br />STRUCTURE (EACH <br />SIDE) <br />NOTE:OTHER MEANS OF SIESMIC <br />BRACING APPROVED BY LICENSED <br />STATE OF CALIFORNIA STRUCTURAL <br />ENGINEER SHALL BE ALLOWED BUT <br />MUST BE SUBMITTED FOR FINAL AS <br />BUILT DOCUMENTATION. <br />12/9/2024 4:09:15 PM <br />2309147GR <br />ROUND1 <br />BOWLING AND <br />AMUSEMENT <br />2800 N. MAIN ST. SUITE 1100 <br />SANTA ANA, CA 92705 <br />ROUND 1 <br />ENTERTAINMENT <br />3070 SATURN ST. STE. 200 <br />BREA, CA 92821 <br />ELECTRICAL POWER <br />PLAN <br />EP101 <br />MAINPLACE <br />MALL <br />REMODEL <br />10 RECEPTACLE MOUNTED ABOVE FOR MONITOR. COORDINATE LOCATION AND <br />ELEVATION WITH A/V CONTRACTOR PRIOR TO ROUGH-IN. SEE SYSTEMS PLANS <br />AND ARCHITECTURAL DETAILS FOR FURTHER INFORMATION. (NOTE. POWERED <br />THROUGH CONTRACTOR, SEE ONE-LINE DIAG. E-501.) NOTE OFFICE MONITOR <br />SHALL NOT RUN THROUGH A CONTACTOR. <br />9 NOT USED <br />8 NOT USED <br />7 SEE DETAILS AND SPECIFICATIONS FOR SEISMIC BRACING <br />6 E.C. SHALL COORDINATE WITH ARCHITECTURAL TRADES FOR MARKING OF <br />CLEARANCE AREAS ON FLOOR IN FRONT OF ELECTRICAL GEAR. MARKING BY <br />ARCHITECTURAL TRADES. <br />5 RECEPTACLE FOR GENERAL USE / HOUSEKEEPING AND NOT SPECIFICALLY <br />ARCADE EQUIPMENT. PROVIDE LABEL READING "HOUSEKEEPING". REFER TO <br />DETAIL ON SHEET E-001. <br />4 WIRE BASKET STYLE CABLE TRAY FURNISHED AND INSTALLED BY E.C., TRAY <br />SHALL BE 12" WIDE/4" DEEP. TRAY FINISH SHALL BE BLACK. <br />3 PROVIDE DUPLEX RECEPTACLE FOR BEER VENDOR SIGNAGE, MOUNT 10'-0" A.F.F. <br />2 120V CONNECTION TO FIRE ALARM BOOSTER POWER SUPPLY PANEL. <br />1 REFER TO ONE LINE DIAGRAM FOR CONTACTOR INTERCONNCTIONS. <br />LEGEND SYMBOL INDICATOR <br />ELECTRICAL PLAN NOTES <br />I FIRE ALARM SCOPE SHALL INCLUDE NEW DEVICES AS SHOWN AND/OR REQUIRED BY <br />THE LOCAL AHJ FOR THE EXPANSION. EXTEND EXISTING SYSTEM INTO EXPANSION <br />AREA AND MATCH SYSTEM FUNCTION. PROVIDE ALL NECESSARY WIRING, <br />COMPONENTS AND INSTALLATION FOR A COMPLETE COMPLINAT SYSTEM. <br />H PROVIDE AND MAINTAIN TEMPORARY POWER AND LIGHTING ADEQUATE FOR SAFE <br />WORKING CONDITIONS USING LUMA-SITE 400W MH FIXTURES OR EQUAL. PROVIDE A <br />MINIMUM OF 40 LUMENS PER SQUARE FOOT. MAINTAIN A STOCK OF SPARE LAMPS AND <br />FIXTURES AT THE JOB SITE TO ENSURE THAT SAFE LIGHT LEVELS ARE MAINTAINED AT <br />ALL TIMES. USE OF STRING LIGHTS AND/OR WOBBLE LIGHTS WILL NOT BE PERMITTED <br />WITHOUT APPORVAL OF THE GENERAL CONTRACTOR FIELD MANAGER. <br />G E.C. SHALL PROVIDE BOX AND CONDUIT PROVISIONS FOR AUDIO/VISUAL, DATA, <br />SECURITY AND COMMUNICATIONS SYSTEMS IN ADDITION TO WHAT IS SHOWN ON THE E <br />SERIES SHEETS. REFERENCE THE AV SERIES SHEETS FOR THIS ADDITIONAL <br />INFORMATION. <br />F E.C. SHALL PROVIDE BOX WITH CONDUIT TO ACCESSIBLE CEILING SPACE OR <br />STRUCTURE WITH BUSHINGS FOR ALL HVAC SENSORS AND THERMOSTATS. REFER TO <br />MECHANICAL PLANS FOR LOCATIONS. <br />E ARCADE SHUTDOWN: ARCADE MACHINES SHALL HAVE MANUAL SHUT DOWN AT <br />DESIGNATED CONTROL STATION LOCATIONS OF THE LIGHTING CONTROL SYSTEM VIA <br />RELAY DRIVING CONTACTORS POWER FEEDS TO ALL ARCADE MACHINE POWER. REFER <br />TO CONTROL SCHEDULES AND DETAILS. <br />D NOT USED <br />C DO NOT SHARE NEUTRALS FOR ARCADE, COMPUTER OR OTHER SPECIAL SYSTEMS <br />CIRCUITS. PROVIDE DEDICATED NEUTRALS. <br />B ALL ELECTRICAL DEVICES, CONDUIT AND EQUIPMENT SHALL BE COORDINATED IN FIELD <br />TO NOT INTERFERE WITH ANY ELEMENTS OF THE ROUND ONE DECOR PACKAGE, <br />INCLUDING ANY ASSOCIATED TRIM WORK AND SIGNS. REFER TO THE ARCHITECTURAL <br />DECOR DRAWINGS. <br />A MOUNTING DIMENSIONS CALLED OUT ON THE PLANS ARE A.F.F. TO BOTTOM OF BOX <br />UNLESS OTHERWISE NOTED. <br />ELECTRICAL GENERAL NOTES <br />CLIENT <br />ARCHITECTS <br />PARADIGM <br />415 Leonard Street NW, Suite 200 <br />Grand Rapids, MI 49504 <br />(616) 785-5656 <br />www.paradigmae.com <br />Grand Rapids | Phoenix | Traverse City <br />DESIGN <br />ENGINEERS| <br />DATE DESCRIPTION <br />RELEASE DATE <br />SHEET <br />PROJECT <br />PROJECT <br />12-09-24 Permits <br />SCALE:N <br />PLAN <br />3/32" = 1'-0" <br />FIRST FLOOR ELECTRICAL POWER PLAN <br />SCALE:1/8" = 1'-0"EP101 <br />OVERHEAD TRANSFORMER DETAIL2 <br />EL101