My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2800 N Main St Unit# 1100 - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Main St
>
2800 N Main St Unit# 1100 Bldg# 2810
>
2800 N Main St Unit# 1100 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:22 AM
Creation date
2/13/2026 5:00:40 AM
Metadata
Fields
Template:
Plan
Permit Number
20185547
40140186
101124821
Full Address
2800 N Main St Unit# 1100 Bldg# 2810
Street Number
2800
Street Direction
N
Street Name
Main
Street Suffix
St
Building Number
2810
Unit Number
1100
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
647
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SD SD <br />NOTE: <br />1.RTU'S INCLUDE POWERED SERVICE RECEPTACLES FURNISHED <br />WITH UNIT BY FACOTRY. FED AHEAD OF UNIT DISCONNECT. <br />2. RTU'S FURNISHED WITH (2) DUCT SMOKE DETECTORS EACH. E.C. <br />SHALL CONNECT DUCT DETECTORS TO NEW FIRE ALARM SYSTEM <br />AND PROVIDE REMOTE TEST DEVICES INSIDE ROUND 1 SPACE AT <br />NEAREST ACCESSIBLE COLUMN AS REQUIRED BY LOCAL AHJ. <br />3. ALL RTU'S ARE FURNISHED WITH DISCONNECT SWITCHES. <br />ROOF PENETRATIONS AND REPAIR <br />CONTRACTOR SHALL USE LANDLORD'S ROOF <br />CONTRACTOR FOR SEALING OF ALL PENETRATIONS <br />AND REPAIRS NEEDED FOR THIS PROJECT. <br />NEW RTU-1 <br />UNIT IS A REPLACEMENT AT SAME LOCATION <br />RECONNECT WITH NEW FEEDER FROM EXISTING PANEL H <br />(SEE ONE LINE DIAGRAM) <br />LOCATION OF <br />EXISTING PANEL <br />"H" (BELOW) <br />12/9/2024 4:09:19 PM <br />2309147GR <br />ROUND1 <br />BOWLING AND <br />AMUSEMENT <br />2800 N. MAIN ST. SUITE 1100 <br />SANTA ANA, CA 92705 <br />ROUND 1 <br />ENTERTAINMENT <br />3070 SATURN ST. STE. 200 <br />BREA, CA 92821 <br />ELECTRICAL POWER <br />PLAN ROOF <br />EP103 <br />MAINPLACE <br />MALL <br />REMODEL <br />SCALE:N <br />PLAN <br />3/32" = 1'-0" <br />ELECTRICAL POWER PLAN ROOF <br />CLIENT <br />ARCHITECTS <br />PARADIGM <br />415 Leonard Street NW, Suite 200 <br />Grand Rapids, MI 49504 <br />(616) 785-5656 <br />www.paradigmae.com <br />Grand Rapids | Phoenix | Traverse City <br />DESIGN <br />ENGINEERS| <br />DATE DESCRIPTION <br />RELEASE DATE <br />SHEET <br />PROJECT <br />PROJECT <br />12-09-24 Permits <br />I FIRE ALARM SCOPE SHALL INCLUDE NEW DEVICES AS SHOWN AND/OR REQUIRED BY <br />THE LOCAL AHJ FOR THE EXPANSION. EXTEND EXISTING SYSTEM INTO EXPANSION <br />AREA AND MATCH SYSTEM FUNCTION. PROVIDE ALL NECESSARY WIRING, <br />COMPONENTS AND INSTALLATION FOR A COMPLETE COMPLINAT SYSTEM. <br />H PROVIDE AND MAINTAIN TEMPORARY POWER AND LIGHTING ADEQUATE FOR SAFE <br />WORKING CONDITIONS USING LUMA-SITE 400W MH FIXTURES OR EQUAL. PROVIDE A <br />MINIMUM OF 40 LUMENS PER SQUARE FOOT. MAINTAIN A STOCK OF SPARE LAMPS AND <br />FIXTURES AT THE JOB SITE TO ENSURE THAT SAFE LIGHT LEVELS ARE MAINTAINED AT <br />ALL TIMES. USE OF STRING LIGHTS AND/OR WOBBLE LIGHTS WILL NOT BE PERMITTED <br />WITHOUT APPORVAL OF THE GENERAL CONTRACTOR FIELD MANAGER. <br />G E.C. SHALL PROVIDE BOX AND CONDUIT PROVISIONS FOR AUDIO/VISUAL, DATA, <br />SECURITY AND COMMUNICATIONS SYSTEMS IN ADDITION TO WHAT IS SHOWN ON THE E <br />SERIES SHEETS. REFERENCE THE AV SERIES SHEETS FOR THIS ADDITIONAL <br />INFORMATION. <br />F E.C. SHALL PROVIDE BOX WITH CONDUIT TO ACCESSIBLE CEILING SPACE OR <br />STRUCTURE WITH BUSHINGS FOR ALL HVAC SENSORS AND THERMOSTATS. REFER TO <br />MECHANICAL PLANS FOR LOCATIONS. <br />E ARCADE SHUTDOWN: ARCADE MACHINES SHALL HAVE MANUAL SHUT DOWN AT <br />DESIGNATED CONTROL STATION LOCATIONS OF THE LIGHTING CONTROL SYSTEM VIA <br />RELAY DRIVING CONTACTORS POWER FEEDS TO ALL ARCADE MACHINE POWER. REFER <br />TO CONTROL SCHEDULES AND DETAILS. <br />D NOT USED <br />C DO NOT SHARE NEUTRALS FOR ARCADE, COMPUTER OR OTHER SPECIAL SYSTEMS <br />CIRCUITS. PROVIDE DEDICATED NEUTRALS. <br />B ALL ELECTRICAL DEVICES, CONDUIT AND EQUIPMENT SHALL BE COORDINATED IN FIELD <br />TO NOT INTERFERE WITH ANY ELEMENTS OF THE ROUND ONE DECOR PACKAGE, <br />INCLUDING ANY ASSOCIATED TRIM WORK AND SIGNS. REFER TO THE ARCHITECTURAL <br />DECOR DRAWINGS. <br />A MOUNTING DIMENSIONS CALLED OUT ON THE PLANS ARE A.F.F. TO BOTTOM OF BOX <br />UNLESS OTHERWISE NOTED. <br />ELECTRICAL GENERAL NOTES
The URL can be used to link to this page
Your browser does not support the video tag.