My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2800 N Main St Unit# 1100 - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Main St
>
2800 N Main St Unit# 1100 Bldg# 2810
>
2800 N Main St Unit# 1100 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:22 AM
Creation date
2/13/2026 5:00:40 AM
Metadata
Fields
Template:
Plan
Permit Number
20185547
40140186
101124821
Full Address
2800 N Main St Unit# 1100 Bldg# 2810
Street Number
2800
Street Direction
N
Street Name
Main
Street Suffix
St
Building Number
2810
Unit Number
1100
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
647
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
RTU-1 <br />COORDINATE WITH LL TO RAISE SUITE <br />2160 LUCILLE'S BBQ EXHAUST FAN. <br />CURRENT DISTANCE FROM EXISTING <br />RTU INTAKE IS 9'0". <br />3 <br />1751 Barlow St. <br />Traverse City, MI 49686 <br />T 231-947-1707 <br />F 231-947-1710 <br />4801 Henry St. <br />Muskegon, MI 49441 <br />T 231-798-4328 <br />F 231-798-2981 <br />REC #5170 <br />REMODEL <br />12 <br />/ <br />9 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />4 <br />: <br />2 <br />4 <br />: <br />0 <br />5 <br /> <br />P <br />M <br />2309147GR <br />ROUND1 <br />BOWLING AND <br />AMUSEMENT <br />2800 N. MAIN ST. SUITE 1100 <br />SANTA ANA, CA 92705 <br />ROUND 1 <br />ENTERTAINMENT <br />3070 SATURN ST. STE. 200 <br />BREA, CA 92821 <br />MECHANICAL ROOF PLAN <br />M-201 <br />MAINPLACE <br />MALL <br />SCALE:N <br />PLAN <br /> 3/32" = 1'-0" <br />MECHANICAL ROOF PLAN <br />V ALL HVAC UNIT SMOKE DETECTORS SHALL BE CONNECTED TO THE BUILDING FIRE ALARM PANEL TO INITIATE A <br />SUPERVISORY SIGNAL UPON ACTIVATION, BE INTERCONNECTED, AND SHALL SHUT DOWN ALL UNITS SIMULTANEOUSLY UPON <br />ACTIVATION OF ANY ONE SINGLE DETECTOR. ALL HVAC UNIT DUCT-SMOKE DETECTORS SHALL BE TESTED BY CALIBRATED <br />MANOMETER PROVIDED BY THE INSTALLING CONTRACTOR TO ENSURE AIR VOLUME AND VELOCITIES ARE WITHIN THE <br />TOLERANCE SPECIFICATIONS OF THE RATINGS REQUIRED BY THE MANUFACTURER'S DATA ON EACH DUCT-SMOKE <br />DETECTOR INSTALLED WITHIN THE UNIT / DUCTWORK. <br />U FIELD VERIFY THAT ALL MECHANICAL WORK COMPLETED BY THE LANDLORD AS PART OF THE SHELL PACKAGE MATCHES <br />CONDITIONS SHOWN ON PLANS. TENANT MECHANICAL CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND <br />ENGINEER IF IT IS DETERMINED THAT MECHANICAL WORK BY THE LANDLORD DEVIATES SUBSTANTIALLY FROM PLANS. <br />T TEST AND BALANCE CONTRACTOR SHALL BE BROWARD COUNTY CERTIFIED. <br />S ALL FLEX DUCTS SHALL TRANSITION FROM ROUND METAL DUCT TO SAME SIZE FLEX DUCT. PROVIDE PREFORMED 90° <br />TRANSITION ELBOW FOR FLEX DUCT CONNECTION INTO SUPPLY DIFFUSER INLET. 5'0" MAXIMUM LENGTH FOR EACH <br />INDIVIDUAL RUN OF FLEX DUCT PER SECTION 603.4.1 CMC. <br />R ALL MECHANICAL DUCTS AND PIPING PENETRATING RATED ASSEMBLIES SHALL BE SEALED AND FIRE-STOPPED TO COMPLY <br />WITH LOCAL REGULATIONS. FOR REFERENCE, SHAFT WALL CONSTRUCTION IS 1-HR RATED FOR DUCTS ROUTED DOWN TO <br />LOWER LEVEL, DUCT PENETRATIONS INTO AND OUT OF SHAFTS SHALL BE SEALED AND FIRE STOPPED ACCORDINGLY PER <br />CODE REQUIREMENTS. <br />Q COORDINATE ALL ROOF PENETRATIONS WITH LANDLORD. ALL ROOF PENETRATIONS SHALL BE PERFORMED BY THE <br />LANDLORD'S ROOFING CONTRACTOR AT GENERAL CONTRACTOR'S EXPENSE. <br />P ALL EXPOSED DUCTWORK, DIFFUSERS / GRILLES, AND GENERAL HVAC LOCATED IN OPEN CEILING AREAS IN THE LOWER <br />LEVEL SHALL BE BLACK IN COLOR UNLESS OTHERWISE NOTED. ALL EXPOSED DUCTWORK, DIFFUSERS / GRILLES, AND <br />GENERAL HVAC LOCATED IN OPEN CEILING AREAS IN THE UPPER LEVEL SHALL BE WHITE IN COLOR UNLESS OTHERWISE <br />NOTED. DIFFUSERS / GRILLES SHALL BE ORDERED WITH FINISH SPECIFIED IN ASSOCIATED SCHEDULE. MECHANICAL <br />CONTRACTOR SHALL THOROUGHLY CLEAN ALL EXPOSED DUCTWORK SPECIFIED TO BE PAINTED FOR PREPARATION OF <br />PAINTING BY PAINTING CONTRACTOR. ALL OILS, DUST AND DEBRIS SHALL BE REMOVED FROM SURFACES REQUIRING <br />PAINTING. OBTAIN WRITTEN APPROVAL FROM MANUFACTURER BEFORE PAINTING DUCT WRAP INSUALTION. UL LISTING MUST <br />NOT BE COVERED. PAINTING MUST OCCUR AFTER ROUGH DUCT INSPECTION. FIRE-WRAPPED GREASE DUCTS SHALL NOT BE <br />PAINTED. <br />O PAINT ALL VISIBLE GAS PIPING TO MATCH ADJACENT SURFACE. ALL GAS PIPING ROUTED ON ROOF SHALL BE PAINTED <br />YELLOW. <br />N ALL SERVICEABLE MECHANICAL EQUIPMENT INSTALLED ON ROOF SHALL BE INSTALLED A MINIMUM OF 10FT FROM ROOF <br />EDGE OR HAVE GUARD RAIL AS REQUIRED BY CODE. MAINTAIN MANUFACTURER RECOMMENDED CLEARANCES. <br />M EXHAUST TERMINATIONS, PLUMBING VENTS, ETC. SHALL BE A MINIMUM OF 3FT. VERTICAL CLEARANCE ABOVE OR MINIMUM <br />OF 10FT. HORIZONTAL CLEARANCE FROM FENESTRATION OR EQUIPMENT OUTDOOR AIR INTAKES. <br />L ALL SUPPLY, RETURN AND EXHAUST DUCT ELBOWS SHALL BE SMOOTH RADIUS ELBOWS WITH THE INSIDE RADIUS SAME AS <br />WIDTH OF DUCT UNLESS OTHERWISE NOTED OR APPROVED BY THE ENGINEER. ALL 90° MITERED ELBOWS SHALL HAVE <br />TURNING VANES. <br />K ALL SUPPLY, RETURN AND EXHAUST BRANCH DUCTS SHALL HAVE A BALANCING DAMPER NEAR MAIN. (INDIVIDUAL BRANCH <br />DAMPERS NOT SHOWN ON PLANS) <br />J ALL RECTANGULAR RETURN DUCTWORK SHALL HAVE 1" INTERNAL LINER, REFER TO SPECIFICATIONS. <br />I INSTALLING CONTRACTOR SHALL USE EXTREME CAUTION TO COORDINATE THE EXACT ROUTING AND ELEVATION OF DUCTING <br />SYSTEMS. THIS CONTRACTOR SHALL INSTALL DUCTING SO AS TO NOT INTERFERE WITH THE REMOVAL AND/OR SERVICING OF <br />SYSTEMS. <br />H ALL DUCT DIMENSIONS ARE INSIDE DIMENSIONS. <br />G FIELD VERIFY THERMOSTAT AND SENSOR LOCATIONS WITH OWNER. INSTALL SENSORS AT A HEIGHT OF ±4'-0" A.F.F.. <br />COORDINATE MECHANICAL SENSOR LOCATIONS WITH OTHER TRADES, INSTALL SENSORS ±6"-1'0" ABOVE LIGHTING <br />CONTROLS WHEN INSTALLED IN SIMILAR LOCATIONS. <br />F ALL WORK SHOWN ON THIS PLAN TO BE COORDINATED WITH ALL OTHER TRADES PRIOR TO FABRICATION AND <br />INSTALLATION. <br />E ALL DUCTWORK BEHIND GRILLES AND DIFFUSERS CONNECTIONS SHALL BE PAINTED FLAT BLACK. PAINT INSIDE OF DUCT <br />CONNECTIONS 2'-0" UP STREAM OF FIRST 90 DEGREE ELBOW. <br />D ALL DUCTWORK SHALL BE INSULATED ACCORDING TO WRITTEN SPECIFICATIONS UNLESS OTHERWISE NOTED. <br />C ALL DUCT AND EQUIPMENT ELEVATIONS NOTED ON PLANS MEASURED FROM F.F. TO BOTTOM OF DUCT/EQUPMENT UNLESS <br />OTHERWISE NOTED. <br />B REFER TO WRITTEN SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. <br />A ALL WORK SHALL BE INSTALLED PER LOCAL, STATE, & FEDERAL CODES, RULES, ORDINANCES, AND REGULATIONS. <br />MECHANICAL GENERAL NOTES <br />3 CONNECT EXISTING GAS PIPING TO NEW RTU-1. <br />2 SHIFT DUCT DOWN TO AVOID STRUCTURE, APPROXIMATELY 11 ’1” A.F.F. BOD THEN BACK UP TO ANNOTATED ELEVATION. <br />1 REFER TO EXISTING DRAWINGS FOR DUCTWORK CONTINUATION. <br />LEGEND SYMBOL INDICATOR <br />MECHANICAL PLAN NOTES <br />TENANT <br />CONSULTANT <br />ARCHITECTS <br />PARADIGM <br />www.paradigmae.com <br />Grand Rapids | Phoenix | Traverse City <br />DESIGN <br />ENGINEERS| <br />DATE DESCRIPTION <br />RELEASE DATE <br />SHEET <br />PROJECT <br />PROJECT <br />10-03-24 LANDLORD REVIEW <br />12-09-24 PERMITS
The URL can be used to link to this page
Your browser does not support the video tag.