18 <br />" <br />MIN <br />I <br />M <br />U <br />M <br />REDUCER <br />(TYP.) <br />N.C. <br />1/4" F.P.T. AND <br />PLUG TEST <br />PORT, TYPICAL <br />GAS COCK N.C. <br />UNION (TYP.) <br />FISHER HSR GAS PRESSURE <br />REDUCING VALVE, INSTALL <br />VALVE WITH SELF DRAINING <br />VENT <br />ROOF <br />PROVIDE SHORT <br />VENT NIPPLE <br />TURNED DOWN <br />MEDIUM <br />PRESSURE <br />LOW <br />PRESSURE <br />WW <br />D <br />45° <br />45° <br />R1 <br />R2 <br />* SMALL DOUBLE VANE ELBOW. <br /> USE FOR ELBOWS UP TO 36" <br /> IN WIDTH AND/OR DEPTH. <br />DIMENSIONS : <br />W = 1.14" <br />D = 2.125" <br />R1 = 1.00" <br />R2 = 2.00" <br />NOTES: <br />1. ALL SQUARE OR RECTANGULAR ELBOWS SHALL HAVE ONE OF THE TWO <br /> TYPES OF TURNING VANES SHOWN. SINGLE VANE ELBOWS WILL NOT BE <br /> PERMITTED ONLY ON RADIUS ELBOWS FOR ALL DUCTS LESS THAN 12" <br /> WIDE. <br />2. VANES SHALL BE CONSTRUCTED, SUPPORTED AND FASTENED AS REQUIRED. <br /> ALL SQUARE OR RECTANGULAR ELBOWS SHOWN ON PLANS FOR EXHAUST <br /> OR RETURN DUCT MAY BE MADE RADIUS ELBOWS PROVIDED SPACE PERMITS <br /> RADIUS INSTALLATION. <br />3. ALL SQUARE OR RECTANGULAR ELBOWS SHOWN ON PLANS FOR SUPPLY DUCT <br /> MAY BE MADE RADIUS ELBOWS PROVIDED SPACE PERMITS RADIUS INSTALLATION, <br /> AND/OR THERE IS NOT AN OUTLET OR TAKEOFF WITHIN 5 DIAMETERS OF THE <br /> DOWNSTREAM SIDE OF THE ELBOW. <br />WIDTH <br />DE <br />P <br />T <br />H <br />SIDE VIEWFRONT VIEW <br />TYPICAL ELBOW <br />NO SCALE <br />MECH. CONTR. <br />INSULATED DUCTWORK BY <br />ROOF TOP A.C. UNIT <br />ROOF <br />CANVAS CONNECTION <br />JOIST <br />STEEL BEAM <br />HURRICANE HOLD DOWN CLIPS <br />WITH 16 GAUGE STIFFNERS <br />WELDED TO ROOF CURB BY CURB <br />MANUFACTURER @ 2'-0" CENTERS <br />MIN. (2) STRAPS PER SIDE. <br />SECURE HOLD DOWN TO UNIT <br />WITH (4) #10x1/2" TEK SCREWS <br />SECURE TIE DOWN STRAPS TO <br />ANGLE WITH (2) #14 TEK <br />SCREWS <br />ANGLE IRON FRAMING <br />BY GENERAL CONTRACTOR. <br />16 GAUGE CURB TIE DOWN <br />STRAPS @ 2'-0" CENTERS <br />MIN. (2) STRAPS PER SIDE <br />WOOD BLOCKING <br />BY MECH. CONTR. <br />SECURE HOLD DOWN <br />TO CURB WITH (8) # <br />10x1/2" TEK SCREWS <br />SECURE TIE DOWN STRAPS TO <br />CURB WITH (2) #14 TEK SCREWS <br />FACTORY INSTALLED ECONOMIZER <br />MECH. CONTR. SHALL OPEN UP <br />ECONOMIZER PER MANUFACTORY <br />INSTRUCTIONS. <br />ROOF CURB INSULATION <br />FURNISHED AND INSTALLED <br />BY MECH. CONTR. <br />ROOF CURB FURNISHED BY OWNER. <br />ASSEMBLED AND INSTALLED BY MECH. <br />CONTR. <br />SEE CURB DETAIL, THIS SHEET. <br />INTERNALLY INSULATE REFER TO <br />SPECS. <br />OFFSET DUCTWORK AS REQUIRED <br />TO RUN THRU WEB OF JOIST <br />GIRDER FIELD VERIFY CONDITION <br />OFFSET BOTH DUCTS EQUALLY <br />L <br />ENLARGED RTU CURB DETAIL <br />3' 0R L <br />E <br />S <br />S <br />- <br />R <br />E <br />F <br />R <br />I <br />G <br />. <br /> <br />L <br />I <br />N <br />E <br />S <br />HOLD DOWN CLAMP <br />1/4" THICK RUBBER MAT <br />RUBBER SUPPORT WITH 14 <br />GAUGE GALVANIZED STEEL <br />CHANNEL. EQUAL TO MI- <br />FAB C SERIES <br />NOTE: MAY USE IN LIEU OF PILLOW <br />BLOCK PIPESTAND NOTED ON SHEET <br />M-107 IF APPROVED BY MIKE BLECHER <br />AND THE LANDLORD'S ROOFING <br />CONTRACTOR. <br />PAINT INSIDE FLAT BLACK <br />CLG. <br />NECK SIZE <br />12 <br />" <br />x <br /> <br />N <br />E <br />C <br />K <br /> <br />S <br />I <br />Z <br />E <br />18" MIN. <br />1" <br />3" <br />FROM STRUCTURE.ELBOW, SUSPEND1" THICK, FIBERGLASS <br />PIPING SUPPORT FOR ALL PIPING <br />RUNNING ON ROOF MIRO INDUSTRIES. <br />60 MIL UNCURED RUBBER FLASHING OR <br />MFG'S. OPTIONAL SUPPORT PAD. <br />PIPE <br />EQUAL TO MIRO, MODEL 6-RHA-12 <br />6" PIPE SUPPORT <br />4" PIPE SUPPORT <br />EQUAL TO MIRO, MODEL 5-RHA-7 <br />1 1/2"-3" PIPE SUPPORT <br />EQUAL TO MIRO, MODEL 3-R-2 <br />1/2"-1 1/4" PIPE SUPPORT <br />EQUAL TO MIRO, MODEL 3-R-2 <br />PIPE <br /> SUPPORT SCHEDULE <br />ALL MODELS OF SUPPORTS SHALL BE FURNISHED <br />WITH THE OPTIONAL STRAPS OVER THE PIPE AND <br />BOLTED TO SUPPORT. ALL METAL SHALL BE OF <br />STAINLESS STEEL CONSTRUCTION. <br />NOTE: <br />SUPPORTS SHALL BE FURNISHED AS THE <br />MANUFACTURERS STANDARD. ADJUST HEIGHT AS <br />REQUIRED FOR SITE CONDITIONS. <br />45° LEAD-IN. <br />SUPPLY AIR MAIN <br />DUCTWORK <br />BRANCH DUCTWORK. <br />D1 <br />D2 <br />NOTE: <br />D1 NOT LESS THAN D2. <br />VOLUME DAMPER <br />4 DUC <br />T <br /> <br />D <br />I <br />A <br />M <br />E <br />T <br />E <br />R <br />S <br /> <br />( <br />D <br />2 <br />) <br /> <br />M <br />I <br />N <br />. <br />AIRFL <br />O <br />W <br />AIRFL <br />O <br />W <br />AIRFL <br />O <br />W <br />AIRFL <br />O <br />W <br />3/8" CADMIUM PLATED <br />THREADED ROD. SECURE <br />TO STRUCTURE (2 TYP). <br />GALVANIZED DUCT AND <br />INSULATION AS SPECIFIED <br />ON PLANS <br />2" x 2" x 1/8" MIN <br />(GALVANIZED) <br />TWO HEAVY HEX NUTS, BACK <br />TO BACK WITH WASHER (TYP <br />EACH CONNECTION) <br />NOTES: <br />1. CONTRACTOR SHALL VERIFY ALLOWABLE LOAD FOR EACH TRAPEZE HANGER PER <br /> SMACNA HVAC DUCT CONSTRUCTION STANDARDS. <br />2. CONTRACTOR MAY SUBSTITUTE STRAP HANGERS ON DUCTS LESS THAN 36" WIDE. <br />45° <br />D <br />DIMENSIONS: <br />D = 6" <br />BRANCH DUCT <br />BALANCING DAMPER <br />(REQ'D IF BRANCH <br />SERVES A SINGLE AIR <br />DISTRIBUTION DEVICE) <br />PRIMARY SUPPLY AIR/OUTSIDE AIR <br />RETURN/EXHAUST AIR <br />TURN DOWN <br />OPEN FOR DRAWTHRU <br />RTU OR <br />AHU <br />DRAIN <br />PAN <br />B <br />A <br />BLOWTHRU <br /> A = GREATER OF 4" OR 1/2" PLUS AHU TOTAL <br /> PRESSURE IN INCHES-WC. <br />DRAWTHRU <br /> B = GREATER OF 2" OR 1/2" PLUS AHU TOTAL <br /> PRESSURE IN INCHES-WC <br />DIELECTRIC UNION <br />AS <br />REQUIRED <br />1"MIN. <br />PROVIDE SUPPORT <br />AS REQUIRED. <br />FOR BLOWTHRU PROVIDE <br />THREADED CLEANOUT <br />FITTING WITH PLUG. <br />M.C. SHALL FURNISH AND <br />INSTALL 8x8 CONCRETE <br />PAVER BELOW CONDENSATE <br />TERMINATIONS ON ROOF. <br />GAS LINE TO UNIT <br />PIPE REDUCER FROM BRANCH <br />PIPE SIZE TO UNIT CONNECTION <br />SIZE. PROVIDE AT UNIT. <br />UNION <br />GAS COCK <br />EXTERIOR OF THE BUILDING.NOTE: OMIT DIRT LEG ATDIRT LEG <br />1751 Barlow St. <br />Traverse City, MI 49686 <br />T 231-947-1707 <br />F 231-947-1710 <br />4801 Henry St. <br />Muskegon, MI 49441 <br />T 231-798-4328 <br />F 231-798-2981 <br />REC #5170 <br />REMODEL <br />12 <br />/ <br />9 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />4 <br />: <br />2 <br />4 <br />: <br />1 <br />0 <br /> <br />P <br />M <br />2309147GR <br />ROUND1 <br />BOWLING AND <br />AMUSEMENT <br />2800 N. MAIN ST. SUITE 1100 <br />SANTA ANA, CA 92705 <br />ROUND 1 <br />ENTERTAINMENT <br />3070 SATURN ST. STE. 200 <br />BREA, CA 92821 <br />MECHANICAL DETAILS <br />M-501 <br />MAINPLACE <br />MALL <br />NOT TO SCALEM-501 <br />SQUARE OR RECTANGULAR ELBOW WITH TURNING VANES1 <br />NOT TO SCALEM-501 <br />ROOF CURB DETAIL2 <br />NOT TO SCALEM-501 <br />REFRIGERANT PIPING SUPPORT DETAIL5 <br />NOT TO SCALEM-501 <br />RETURN AIR GRILLE BOOT DETAIL3 <br />NOT TO SCALEM-501 <br />PIPE ON ROOF DETAIL11 <br />NOT TO SCALEM-501 <br />BRANCH CONNECTION DETAIL8 <br />NOT TO SCALEM-501 <br />RECTANGULAR DUCT TRAPEZE HANGER7 <br />NOT TO SCALEM-501 <br />RECTANGULAR BRANCH DUCT DETAIL9 <br />NOT TO SCALEM-501 <br />UNIT COOLING COIL CONDENSATE DRAIN DETAIL10 <br />NOT TO SCALEM-501 <br />GAS CONNECTION DETAIL4 <br />NOT TO SCALEM-501 <br />ABOVE ROOF GAS PRESSURE REDUCING STATION6 <br />TENANT <br />CONSULTANT <br />ARCHITECTS <br />PARADIGM <br />www.paradigmae.com <br />Grand Rapids | Phoenix | Traverse City <br />DESIGN <br />ENGINEERS| <br />DATE DESCRIPTION <br />RELEASE DATE <br />SHEET <br />PROJECT <br />PROJECT <br />10-03-24 LANDLORD REVIEW <br />12-09-24 PERMITS