Laserfiche WebLink
30'-0'' <br />PL TO CL OF STREET <br />19'-6" <br />CURB <br />& GUTTER to CL OF STREET <br />10'-6" <br />PL TO CURB <br />5'- <br />0 <br />" <br />SI <br />D <br />E <br /> <br />Y <br />A <br />R <br />D <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />5'-0" <br />REAR YARD SETBACK <br />20'-0" <br />FRONT YARD SETBACK <br />5'- <br />0 <br />" <br />SI <br />D <br />E <br /> <br />Y <br />A <br />R <br />D <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />1'-6" <br />5'-0" <br />3'-6" <br />1' <br />- <br />6 <br />" <br />5' <br />- <br />0 <br />" <br />3' <br />- <br />6 <br />" <br />56'-10 1/2" <br />1'-6" <br />5' <br />- <br />6 <br />" <br />5' <br />- <br />0 <br />" <br />10 <br />' <br />- <br />6 <br />" <br />59'-4 1/2" <br />5'- <br />0 <br />" <br />SI <br />D <br />E <br /> <br />Y <br />A <br />R <br />D <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />3'-0" <br />GABLE VENT <br />ROOF RIDGE <br />VENTILATION <br />CEILING JOIST <br />CEILING <br />INSULATION <br />EAVE VENTILATION <br />MECHANICAL <br />ROOF VENT MA <br />I <br />N <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />: <br />27 <br />1 <br />7 <br /> <br />H <br />U <br />C <br />K <br />L <br />E <br />B <br />E <br />R <br />R <br />Y <br /> <br />R <br />D. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />C <br />A <br /> <br />92 <br />7 <br />0 <br />6 <br />B <br />A <br />O <br /> <br /> <br />P <br />H <br />A <br />M <br /> <br /> <br />D <br />E <br />S <br />I <br />G <br />N <br /> <br /> <br />O <br />F <br />F <br />I <br />C <br />E <br />LICENSED ARCHITECT <br />STATEOF C ALIFORNIA <br />C-39025 <br />REN. 08/31/25 <br />BAO PHAM <br />ARCHITECT OF RECORD: <br />BAO PHAM, RA <br />1 <br />310 N <br /> <br />HA <br />R <br />BOR <br />BLV <br />D. S <br />AN <br />T <br />A <br /> <br />AN <br />A <br />CA <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br /> <br />| b <br />a <br />o <br />@b <br />p <br />d <br />o <br />-ar <br />ch <br />i <br />te <br />cts.c <br />o <br />m <br /> <br /> <br />| 71 <br />4 <br />. <br />4 <br />5 <br />7 <br />. <br />0 <br />4 <br />3 <br />6 <br />DE <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />P1 <br />1 <br />ISSUANCE <br />Designed plans and specifications <br />represented by these drawings are <br />properties of BPDO and were <br />developed for use in connection with <br />each particular project. None of these <br />plans and ideas shall be used, <br />duplicated, disclosed, in part or in <br />whole, without written permission of <br />BPDO. <br />2025.02.19 CYCLE 1 PLN SUBMITTAL <br />DE <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />: <br />27 <br />1 <br />9 <br /> <br />H <br />U <br />C <br />K <br />L <br />E <br />B <br />E <br />R <br />R <br />Y <br /> <br />R <br />D. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />C <br />A <br /> <br />92 <br />7 <br />0 <br />6 <br />2025.03.26 CYCLE 2 PLN SUBMITTAL <br />2025.04.23 CYCLE 1 BLDG SUBMITTAL <br />2025.06.10 CYCLE 2 BLDG SUBMITTAL <br />PROPOSED SITE PLAN <br />AND ROOF PLAN <br />1.ROOF OPENINGS SHALL HAVE CORROSION-RESISTANT WIRE MESH OR OTHER <br />APPROVED MATERIAL WITH 1/6 INCH MINIMUM AND 1/4 INCH MAXIMUM OPENING <br />2.A MINIMUM OF 1 INCH AIR SPACE SHALL BE PROVIDED BETWEEN INSULATION AND <br />ROOF SHEATHING <br />3.UNVENTED ATTIC ASSEMBLIES SHALL MEET ALL THE CONDITIONS IN SECTION <br />R806.4 <br />4.TYPICAL ROOF OVERHANG 1'-6" - U.N.O <br />5.TYPICAL ROOF OVERHANG RAKE 1'-6" - U.N.O <br />6.BUILT UP MEMBRANE TYPICALLY W/ BITUTHENE MEMBRANE - U.N.O <br />7.FRAMER SHALL BE RESPONSIBLE FOR COORDINATING W/ TRUSS MANUFACTURER <br />TO ACCOMMODATE ALL ATTIC VENTS. <br />8.ALL VENTS SHALL BE INSTALLED SO AS TO MAKE THEM WATER PROOF AND WALL <br />MOUNTED LOUVERS SHALL BE SEALED AND FLASHED WITH "MOISTOP" IN THE <br />SAME MANNER PRESCRIBED FOR WINDOW INSTALLATION <br />9.PROVIDE APPROVED INSULATION DAMS ( BAFFLES) WHERE VENT BLOCKS ARE <br />USED BETWEEN ROOF FRAMING MEMBERS TO PREVENT HOLES <br />ROOF NOTES <br />ROOF VENTILATIION DIAGRAM <br />ROOF SPECIFICATION: <br />1.ROOF: CLASS 'A' FIRE RATING - <br />ROOF MATERIAL: SHINGLE CLASS "A" MIN <br />OWENS CORNING ROOFING <br />ASPHALT - CRRC: 0890-0014 <br />ICC-ESR 2664 / UL ER2453-01 <br />ICC-ES ESR-1389 W/ LAYERS OF <br />UNDERLAYMENT <br />OWENS CORNING RIDGE VENT <br />ICC-ESR 2664 /UL 790 <br />UNDERLAYMENT: ASTM D 226, <br />TYPE I OR ASTM D 4869 TYPE I <br />PER 2022 CBC CHAPT. 15 OR <br />2022 CRC R902.1 <br />MFG: AIR VENT INC. OR EQUAL <br />PRODUCT INFO: <br />ALUMINUM GABLE VENT <br />FLUSH FLANGE <br />MFG: O'HAGIN OR EQUAL <br />PRODUCT INFO: <br />TAPERED LOW-PROFILE VENTS <br />CLASS A RATED <br />STAINLESS STEEL <br />MFG: <br />MAURICE FRANKLIN OR EQUAL <br />PRODUCT INFO: <br />2.5" <br />ALUMINUM <br />STAINLESS STEEL <br />EQ EQ EQ EQ <br />1/ <br />2 <br />" <br />1/ <br />2 <br />" <br />FOR REFERENCE ONLY <br />SP1.1 <br />GENERAL NOTES <br />RESIIDENCE ADDRESSING SHALL BE EASILY VISIBLE FROM HUCKLEBERRY RD. TO AID EMERGENCY RESPONDERS, <br />APPROVED BUILDING ADDRESS NUMBERS SHALL BE PROVIDED AND MAINTAINED SO AS TO BE PLAINLY VISIBLE AND LEDGIBLE FROM THE STREET FRONTING THE <br />PROPERTY. THE NUMBERS SHALL CONTRAST WITH THEIR BACKGROUNDS, BE ILLUMINATED ARABIC NUMERALS , AND BE A MINIMUM OF 4 INCHES HIGH WITH A <br />MINIMUM STROKE WIDTH OF .5 INCHES. CFC CHAPTER 5, SECTION 505.1 <br />LANDSCAPING MAINTAINED NOT TO INTERFERE WITH LIGHTING OR ADDRESSING <br />ASPHALT RESTORATION SHALL BE PER CITY OF FULLERTON STANDARD PLAN NO.’S 120, 121, AND 219. <br />ANY ALTERATION OR RELOCATION TO EXISTING UTILITIES METERS SUCH AS GAS, WATER AND ELECTRICAL MUST BE NOTIFIED TO BUILDING INSPECTOR FOR <br />APPROVAL PRIOR TO COMMENCE WORK <br />THERE SHALL BE NO TRENCHES OR EXCAVATION 5 FEET OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND, OR OBTAIN PERMIT FROM <br />STATE OF CALIFORNIA, DIVISION OF OCCUPATIONAL SAFETY AND HEALTH (CAL/OSHA) THIS PERMIT AND ANY OTHER SAFETY PERMIT SHALL BE OBTAINED <br />PRIOR TO COMMENCEMENT OF ANY WORK. CONTACT CAL/OSHA AT: 714-558-4451 FOR ADDITIONAL INFORMATION <br />ADDITION THAT EXCEED 50% OF THE EXISTING LIVING FLOOR AREA REQUIRE UNDER GROUNDING OF ALL EXISTING ABOVE GROUND UTILITIES. PER BUILDING <br />POLICY, WHERE FEASIBLE, AND AS DETERMINED BY THE BUILDING INSPECTOR, ALL ABOVE GROUND UTILITIES SHALL BE RELOCATED UNDERGROUND. <br />THE GRADE SHALL FALL NOT FEWER THAN 6" WITHIN THE FIRST 10' FROM THE FOUNDATION WALL. WHERE LOT LINES, WALLS, SLOPES OR PHYSICAL BARRIERS <br />PROHIBIT 6" OF FALL WITHIN 10', DRAINS, OR SWALES SHALL BE CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. IMPERVIOUS SURFACES <br />WITHIN 10' OF THE BUILDING SHALL BE SLOPED NOT LESS THAN 2% AWAY FROM THE BUILDING <br />KEY NOTES <br />1 PROPERTY LINE <br />2 <br />3 <br />CURB LINE <br />4 <br />1 <br />5 <br />6 <br />2 <br />4 <br />3 <br />5 <br />HOUSE STREET NUMBER <br />(4) INCHES IN HEIGHT, OF A COLOR <br />CONTRASTING TO THE BACKGROUND <br />EXISTING <br />NEW <br />6 <br />PUBLIC RIGHT OF WAY <br />ELECTRICAL METER <br />4" SEWER MAIN LATERAL <br />PROTECT IN PLACE <br />3/4" WATER METER & <br />DOMESTIC WATER SERVICE <br />8 <br />9 <br />LANDSCAPE <br />CONCRETE PAVING <br />1 HR FIRED RATED EAVE <br />7 <br />GAS METER & GAS LINE <br />200A SERVICE PANEL & DISCONNECT <br />MIN. 4'' ABS SEWER LATERAL MIN 2% SLOPE <br />PER CPC <br />OUTDOOR RATED CONDENSER UNIT UNIT <br />PROVIDE 4'' CONCRETE PAD OR PREFAB PAD. <br />1" WATER METER LINE MIN. 18'' BURIAL <br />DEPTH W/#12 TRACE WIRE WATER SERVICE <br />LINE SHALL NOT BE IN THE SAME TRENCH <br />W/ SEWER LINE AND SHALL MAINTAIN MIN <br />18'' SEPARATION <br />7 SIDE BY SIDE METER UPGRADE PER SCE & <br />CITY'S STDS. ADU: 200A SFR: 200A <br />8 <br />EASTMENTS <br />3' PIPELINES AND INCIDENTAL PURPOSES <br />AS SHOWN ON BOOK 2098, PAGE 559, OF OFFICIAL RECORDS <br />9 <br />10 POWER POLE <br />11 <br />12 <br />MAIN RESIDENCE ADDRESS <br />13 <br />OVERHEAD POWER LINE <br />14 <br />15 <br />72'' CMU WALL <br />ELECT PANEL <br />16 <br />60'' METAL GATE <br />72'' WOOD FENCE AND GATE <br />NEW <br />OVERHEAD DROP PER SCE STD'S <br />EXISTING <br />NEW PAVING <br />1 <br />17 <br />5' AERIAL, UNDERGROUND AND INCIDENTAL PURPOSES <br />AS SHOWN ON BOOK 2102, PAGE 98, OF OFFICIAL RECORDS2 <br />18 <br />36'' WOOD FENCE <br />GRAVEL (RESTORE TO GRASS) <br />SCALE:1 PROPOSED SITE PLAN AND ROOF PLAN <br />1/8" = 1'-0" <br />4 : 12 <br />OVERHANG <br />TYP. <br />10 <br />A3.0 <br />4 <br />: <br /> <br />1 <br />2 <br />4 <br />: <br /> <br />1 <br />2 <br />EMERGENCY SERVICE ACCESSEMERGENCY SERVICE ACCESS <br />1 <br />3 <br />OVERHANG <br />TYP. <br />10 <br />A3.0 <br />EA <br />V <br />E <br /> <br />O <br />V <br />E <br />R <br />H <br />A <br />N <br />G <br />4 <br />OVERHANG <br />TYP. <br />10 <br />A3.0 <br />ADU ATTIC VENTILATION <br /> A B C D E <br /> PLAN ATTIC AREA REQ'D VENTING RIDGE ROOF VENTS EAVE VENTS <br /> VENTS <br />ATTIC AREA <br />( SQUARE <br />FEET) <br />GABLE VENTS: <br />AIR VENT INC. ALUMINUM <br />GABLE VENT 15.75"X26.5" OR EQUAL 92 SQ.IN 8 736 SQ.IN <br />EAVE/ SOFFIT VENTS: <br />2.75 IN. X 96 IN. RECTANGULAR <br />BUILT-IN SCREEN ALUMINUM SOFFIT VENT <br />GIBRALTAR BUILDING PRODUCTS OR EQUAL <br />8' SECTIONS PROVIDE 92 SI VENTILATION <br />11.5 SI/ LF 0 0 SQ.IN <br />RIDGE VENTS: <br />VENTURE RIGID ROLL RIDGE VENT 12.5 SI/ LF 25' 312 SQ.IN <br />ATTIC AREA <br />DIVIDE <br />150 <br />MULTIPLY <br />144 <br />___________ <br />TOTAL REQ'D <br />NET FREE <br />VENTING IN <br />SQUARE INCH <br />TOTAL <br />SQUARE <br />INCH OF NET <br />FREE <br />VENTILATION <br />AREA <br />PROVIDED <br />AT <br />RIDGE <br />TOTAL <br />SQUARE <br />INCH OF <br />NET FREE <br />VENTILATION <br />AREA <br />PROVIDED <br />BY RIDGE <br />VENTS <br />TOTAL <br />SQUARE <br />INCH OF <br />NET FREE <br />VENTILATION <br />AREA <br />PROVIDED <br />UNDER <br />EAVE VENT <br />BLOCKING <br />TOTALAIR FLOW QUANTITY <br />312 SI960 SI1000 SF 312 SI <br />TOTAL VENTING PROVIDED: 1048 SQ.IN <br />0 SI <br />EXISTING DWELLING <br />60 <br />' <br />HU <br />C <br />K <br />L <br />E <br />B <br />E <br />R <br />R <br />Y <br /> <br />R <br />D <br />. <br />PIQ <br />APN: 101-121-17 <br />GROSS AREA: 3,923 SF <br />4 : 12 <br />4 : 12 <br />1 <br />3 <br />2 <br />4 : 12 <br />4 <br />: <br /> <br />1 <br />2 <br />4 <br />: <br /> <br />1 <br />2 <br />⅊ <br />⅊ <br />135.89'1 <br />11 <br />8 <br />⅊1 <br />12 <br />4 <br />7 <br />℄ <br />10 <br />6 <br />60 <br />' <br />⅊ <br />1 <br />⅊135.88'1 ⅊1 <br />⅊ <br />13151414 <br />14 14 <br />17 <br />16 <br />18 <br />8 <br />8 <br />8 <br />8 <br />8 <br />8 <br />8 <br />8 <br />99 <br />5 <br />6 <br />2 <br />2 <br />SO <br />L <br />A <br />R <br /> <br />P <br />A <br />N <br />E <br />L <br />SO <br />L <br />A <br />R <br /> <br />P <br />A <br />N <br />E <br />L <br />V V <br />V <br />V V <br />V <br />V V <br />4 : 12 <br />10 <br />EAVE OVERHANG <br />7 <br />9 <br />OVERHANG <br />TYP. <br />10 <br />A3.0 <br />5 <br />ALL UTILITIES FOR THE ADU TO BE UNDERGROUND <br />PER SAMC SECTION 41-262. <br />EA <br />V <br />E <br /> <br />O <br />V <br />E <br />R <br />H <br />A <br />N <br />G <br />11 <br />2 <br />P1 <br />P1 <br />P1 <br />P1 <br />P1