My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2701 & 2721 S Harbor Bl - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Harbor Blvd
>
2721 S Harbor Blvd
>
2701 & 2721 S Harbor Bl - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:26 AM
Creation date
2/13/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20186081
20186713
101124048
101124744
Full Address
2721 S Harbor Blvd
2701 S Harbor Blvd
Street Number
2701
Street Direction
S
Street Name
Harbor
Street Suffix
Blvd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
125
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />inning and B IildLng Ayer <br />• <br />1 <br />1 <br />Place pallets over girders. Limit <br />; <br />to two pallets per girder in the <br />span between each pair of <br />columns (dash lines). <br />1 <br />1 I <br />1 <br />I <br />1 <br />I I <br />1 <br />i <br />I <br />1 <br />1 <br />R 1 <br />I <br />I <br />� <br />1 <br />1 <br />1 <br />1 <br />JM <br />1 <br />I <br />I <br />; <br />I <br />1 <br />I <br />Do not place pallets <br />1 <br />in the red areas. <br />; 1 <br />I <br />1 <br />, <br />1 <br />APPLICABLE CODES: <br />PERFORM ALL CONSTRUCTION IN CONFORMANCE WITH THE BUILDING AND DESIGN <br />CODES REFERENCED WITHIN THESE DOCUMENTS. THE PROJECT DOCUMENTS REFER TO <br />THE FOLLOWING CODES AND STANDARDS: <br />2022 CA BUILDING CODE <br />2021 INTERNATIONAL BUILDING CODE <br />MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, ASCE 7-16, STANDARD <br />SPECIFICATIONS FOR STEEL JOISTS AND JOIST GIRDERS, SJI 44TH EDITION, SPECIFICATION FOR <br />STRUCTURAL STEEL BUILDINGS ANSI AISC 360-16 <br />GENERAL NOTES: <br />EXISTING CONSTRUCTION GUIDANCE PROVIDED IN THIS DELIVERABLE WAS OBTAINED <br />FROM EXISTING CONSTRUCTION DOCUMENTS. VERIFY GIRDER LOCATIONS SHOWN IN <br />THIS DOCUMENT MATCH WITH THE AS -BUILT CONDITION PRIOR TO COMMENCING WORK <br />NOTIFY ACROS ENERGY OF ANY OBSERVED DISCREPENCIES. <br />THE CONTRACTOR SHALL VERIFY THE EXISTING CONDITIONS OF THE ROOF FRAMING <br />STRUCTURE PRIOR TO INITIATING CONSTRUCTION AND MATERIAL PLACEMENT <br />PROCEDURES. <br />EVERY ATTEMPT SHOULD BE MADE TO ADDRESS ANY OBSERVED DEFFICIENCIES AND <br />THEY SHOULD BE REPORTED IN WRITING TO ACROS ENERGY IN ATIMELY MANNER. <br />THE CONTRACTOR SHALL PERFORM THE WORK WITH A MINIMUM INCONVENIENCE TO <br />THE OWNER AND AS TO NOT INTERRUPTTHE DAY TO DAY WORK OPERATIONS. THE <br />CONTRACTOR SHOULD ENSURE SAFE PASSAGE OF PERSONEL AROUND AREAS OF <br />CONSTRUCTION AND SHALL CONDUCT OPERATIONS TO PREVENT DAMAGE OR HARM TO <br />THE FACILITY AND PEOPLE. COORDINATE ALL OPERATIONS WITH OWNER OR THEIR AGENT <br />Appr v6d <br />IT ISNC <br />W <br />1 Girder locations marked I Dat <br />f by green lines L <br />1 Q 1 <br />1 <br />1 <br />_-7_ _ _ _ _ _ _ _ _ _ - <br />1 1 1 U E <br />U <br />I O W W <br />1 W Q N XXU2 <br />W <br />r¢ZQon <br />W Q H! <br />; I <br />0 � t <br />n. <br />=m w <br />1 ()= UN UHm W 3 w <br />THE CONTRACTOR SHALL VERIFY THE LOCATION OF EXISTING UTILITIES BEFORE <br />BEGINNING WORK. SPECIAL CARE SHALL BE TAKEN TO PROTECT UTILITIES THAT ARE TO <br />REMAIN IN SERVICE DURING CONSTRUCTION. <br />ALL REMAINING ITEMS, MATERIALS AND DEBRIS, UNLESS OTHERWISE NOTED, SHALL BE <br />REMOVED PROMPTLY FROM THE SITE AND DISPOSED IN A LEGAL MANNER. <br />ALL PALLETS SHOULD BE AT LEAST 6'x$' IN DIMENSION AND WEIGHT NO MORE THAN 2600 LBS. <br />IF HEAVIER PALLETS ARE TO BE STAGED OR IF THEIR DIMENSIONS ARE SMALLER, <br />PLEASE CONTACT ACROS WITH CORRESPONDING DIMENSIONS AND WEIGHT. <br />MINIMUM DISTANCE BETWEEN PALLETS TO BE 26 FT O.C. <br />PLACE PALLETS IN ANY GREEN MARKED AREA ON TOP OF ONE (1) 3/4 INCH THICK <br />PLYWOOD SHEET MEASURING 4 FT BY 8 FT. <br />PLYWOOD AND PALLETS TO BE ORIENTED IN THE LONG DIRECTION OVER THE EXISTING <br />GIRDERS. <br />PLACE PALLETS AT LEAST 12 FT AWAY FROM ROOF -TOP UNITS AND ANY HEAVY LOADS <br />HANGING FROM THE UNDERSIDE OF THE ROOF. NOTIFY ACROS OF ANY UNUSUAL LOADS <br />HANGING FROM THE ROOF FRAMING. <br />CONSTRUCTION LOADS NOT TO EXCEED 8 PSF. <br />SNOW LOAD IS NON -CONCURRENT WITH CONSTRUCTION LOAD OR PV PALLETS. THEREFORE PV <br />PALLETS SHOULD BE REMOVED FROM THE ROOF IN A PROPORTIONAL MANNER IF SNOW IS <br />EXPECTED. <br />Q <br />L3 <br />a <br />0 <br />z <br />T <br />l <br />W <br />�1 <br />a <br />V J <br />' ♦ C057196 r1 <br />'>l Cn>t <br />w <br />oa* <br />E0 CA�7� <br />Q <br />7-14-2025 <br />a <br />
The URL can be used to link to this page
Your browser does not support the video tag.