Laserfiche WebLink
25 <br />29 <br />34 <br />27 <br />35 <br />28 <br />36 <br />32 <br />TELECOMMUNICATIONS PROJECT MANAGEMENT <br />16776 BERNARDO CENTER DRIVE, UNIT 203 <br />SAN DIEGO, CA 92128 <br />15 <br />5 <br />0 <br />5 <br /> <br />S <br />A <br />N <br />D <br /> <br />C <br />A <br />N <br />Y <br />O <br />N <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br />, <br /> <br />B <br />L <br />D <br />G <br /> <br />C <br />. <br />IR <br />V <br />I <br />N <br />E <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />1 <br />8 <br />SHEET TITLE: <br />ISSUE STATUS <br />DATEREV.DESCRIPTION BY <br />FI <br />S <br />H <br />E <br />R <br /> <br />F <br />L <br />O <br />R <br />A <br />L <br />26 <br />7 <br />7 <br /> <br />3 <br />/ <br />4 <br /> <br />N <br />. <br /> <br />M <br />A <br />I <br />N <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />W <br />C <br />C <br />0 <br />1 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />0 02/28/2024 90% CD REVIEW jd <br />1 03/15/2024 90% CD DRM COMMENTS jd <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />03/29/2024 <br />05/17/2024 <br />06/21/2024 <br />08/01/2024 <br />09/25/2024 <br />05/07/2025 <br />06/04/2025 <br />90% CD DRM COMNTS #2 <br />100% FINAL CD <br />REVISED DIESEL TANK <br />REGULATORY HEIGHT <br />BP SUBMITTAL <br />100% CD BP PLANCHECK <br />STRUCT PLANCHECK <br />jd <br />jd <br />rl <br />jd <br />jd <br />jd <br />JD <br />D-3 <br />PROPRIETARY INFORMATION <br />THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS <br />IS PROPRIETARY TO VERIZON WIRELESS <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />I <br />. <br />D <br />. <br /> <br />1 <br />5 <br />8 <br />6 <br />1 <br />0 <br />6 <br />7 <br />Ren. 4-30-27 <br />No. C 11978 <br />LICENSED A RCHITECT <br />STATE OF CALIFORNIA <br />WILLIAM M. BOOTH <br />DETAILS <br />30 <br />N.T.S. <br />SCALE: <br />26 <br />31 <br />GATE ELEVATION N.T.S. <br />SCALE: <br />N.T.S. <br />SCALE: <br />N.T.S. <br />SCALE: <br />N.T.S. <br />SCALE: <br />4" @ 18"1/8" <br />TYPICAL 3/16" <br />SOLID GROUTED CONCRETE <br />BLOCK WALL PER PLANS <br />(2) #5 REINFORCING <br />BARS <br />1-1/2" DEEP, 20 GA <br />GALVANIZED STEEL <br />CORRUGATED SIDING <br />1-1/2"Ø HOLE FOR MOUNTING <br />BOLTS (VERIFY) <br />2" x 4" x 1/4" THICK GALVANIZED <br />STEEL TUBE FRAME <br />1/ <br />2 <br />" <br />1-1/2" x 2" x 1/8" THICK <br />GALVANIZED STEEL ANGLE <br />2" x 3" x 1/4" THICK <br />GALVANIZED STEEL TUBE <br />GATE FRAME <br />34 <br />D-3 <br />4" @ 18"1/8" <br />(3) HEAVY DUTY GALVANIZED <br />STEEL HINGES WITH <br />NON-REMOVABLE PINS <br />TYPICAL3/16" <br />SOLID GROUTED <br />CONCRETE <br />BLOCK WALL <br />(2) #5 BARS <br />1 1/2" DEEP, 20 GA <br />GALVANIZED STEEL <br />CORRUGATED SIDING <br />1 1/2"Ø HOLE FOR MOUNTING <br />BOLTS (VERIFY) <br />1/ <br />2 <br />" <br />1 1/2" x 2" x 1/8" THICK <br />GALVANIZED STEEL ANGLE <br />2" x 3" x 1/4" THICK <br />GALVANIZED STEEL <br />TUBE GATE FRAME <br />2" x 4" x 1/4" THICK GALVANIZED <br />STEEL TUBE FRAME <br />34 <br />D-3 <br />GATE JAMB (HINGE)GATE (STRIKE) <br />SIZE PER PLANS <br />8' <br />- <br />0 <br />" <br />4'-0" <br />GALVANIZED STEEL STRIKE <br />PLATE WELDED TO TUBE <br />STEEL FRAME <br />2" x 4" x 1/4" THICK GALVANIZED <br />STEEL TUBE FRAME <br />GRIND ALL WELDS SMOOTH @ <br />FRAME & GATE <br />2" x 3" x 1/4" GALVANIZED <br />STEEL TUBE GATE FRAME <br />PADLOCK LOOP FOR HIDDEN <br />SHACKLE PADLOCK ON STEEL <br />GATE FRAME. PROVIDE VANDAL <br />RESISTANT GATE LOCK COVERCONCRETE SLAB <br />3" <br />(3) HEAVY DUTY GALVANIZED <br />STEEL HINGES WITH <br />NON-REMOVABLE PINS <br />(4) "HILTI" 5/8"Ø STAINLESS STEEL <br />KWIK BOLT TZ2 MASONRY ANCHORS <br />EQUALLY SPACED WITH 4-1/2" <br />EMBED. INTO 5/8"Ø HOLE DRILLED <br />4-3/4" DEEP. SPECIAL INSPECTION <br />REQUIRED (ICC ESR-4561). <br />29 <br />D3 <br />(4) "HILTI" 5/8"Ø STAINLESS STEEL <br />KWIK BOLT TZ2 MASONRY ANCHORS <br />EQUALLY SPACED WITH 4-1/2" <br />EMBED. INTO 5/8"Ø HOLE DRILLED <br />4-3/4" DEEP. SPECIAL INSPECTION <br />REQUIRED (ICC ESR-4561). <br />16 <br />D-2 <br />18" x 30" LOUVERED VENT <br />1-1/2" DEEP 20 GA. GALVANIZED <br />STEEL CORRUGATED SIDING <br />102 <br />D-9 <br />NOTE: GENERAL CONTRACTOR TO CONFIRM WITH THE RFE / EME STUDY WHICH WARNING <br />PLACARD TO INSTALL, WHERE TO INSTALL, AND NOT TO INSTALL THEM IF NOT REQUIRED. <br />PADLOCK LOOP ON GALVANIZED <br />STEEL GATE FRAME & PROVIDE <br />VANDAL RESISTANT GATE LOCK <br />COVER <br />5" x 4" x 3/8" THICK GALVANIZED <br />STEEL STRIKE PLATE WELDED <br />TO TUBE STEEL FRAME <br />30 <br />D3 <br />N.T.S. <br />SCALE: <br />N.T.S. <br />SCALE: <br />N.T.S. <br />SCALE: <br />N.T.S. <br />SCALE:CHAIN LINK SUPPORT AND BRACKETCHAIN LINK SUPPORT AND BRACKETCHAIN LINK SUPPORT AND BRACKET SUPPORT POST AND BRACKET <br />1/2"Ø GALVANIZED <br />STEEL PIPE CLAMP <br />1/4" THICK GALVANIZED <br />STEEL PLATE <br />(2) 3"Ø GALVANIZED <br />PIPE FRAME FOR LID <br />2 <br />1 <br />/ <br />2 <br />" <br />7" <br />2 <br />1 <br />/ <br />2 <br />" <br />4" <br />2" <br />1' <br />- <br />0 <br />" <br />9/16"Ø HOLES <br />1/4" THICK GALVANIZED <br />STEEL PLATE <br />GALVANIZED STEEL PIPES <br />SHOWN DASHED FOR CLARITY <br />1/2"Ø GALVANIZED <br />STEEL PIPE CLAMP <br />1/2"Ø GALVANIZED <br />STEEL PIPE CLAMP <br />CONCRETE BLOCK WALL <br />SOLID GROUTED <br />1' <br />- <br />0 <br />" <br />(4) 1/2"Ø x 4 1/2" EMBED. HOT DIPPED <br />GALVANIZED THREADED STEEL ROD. <br />DRILL 5/8"Ø HOLE & FILL WITH "HILTI" <br />HIT HY-270 ADHESIVE. <br />(4" MINIMUM EDGE DISTANCE) <br />(ICC ESR-4143). **SPECIAL <br />INSPECTION REQUIRED. <br />CONTRACTOR TO AVOID CUTTING OR <br />DAMAGING WALL REINFORCING.GALVANIZED STEEL PIPES <br />SHOWN DASHED FOR CLARITY <br />9/16"Ø HOLES <br />1/4" THICK <br />GALVANIZED <br />STEEL BENT <br />PLATE <br />1/2"Ø GALVANIZED <br />STEEL PIPE CLAMP <br />CONCRETE <br />BLOCK WALL <br />10" <br />4"4 1/2" <br />1' <br />- <br />4 <br />" <br />1 <br />1 <br />/ <br />2 <br />" <br />1' <br />- <br />1 <br />" <br />3" <br />3" <br />10 <br />" <br />1 1/2" <br />25 <br />D-3 <br />27 <br />D-3 <br />(4) 1/2"Ø x 4 1/2" EMBED. HOT DIPPED GALVANIZED THREADED <br />STEEL ROD. DRILL 5/8"Ø HOLE & FILL WITH "HILTI" HIT HY-270 <br />ADHESIVE. (4" MINIMUM EDGE DISTANCE). <br />(ICC ESR-4143). **SPECIAL INSPECTION REQUIRED. CONTRACTOR <br />TO AVOID CUTTING OR DAMAGING WALL REINFORCING. <br />10 <br />" <br />6" <br />2 <br />1 <br />/ <br />4 <br />" <br />5" <br />10" <br />1/4" THICK GALVANIZED <br />STEEL BENT PLATE. <br />3"Ø GALVANIZED PIPE <br />FRAME FOR LID <br />3/16" <br />3/16"TYPICAL <br />3-SIDES <br />3/8" THICK GALVANIZED <br />STEEL GUSSET CENTERED <br />ON BENT PLATE <br />3/8" THICK GUSSET <br />#4 CONTINUOUS <br />SUPPORT POST AND BRACKET <br />9/16"Ø HOLES <br />GALVANIZED STEEL PIPES <br />SHOWN DASHED FOR CLARITY <br />1/2"Ø GALVANIZED STEEL <br />PIPE CLAMP <br />1/4" THICK GALVANIZED <br />STEEL BENT PLATE <br />CONCRETE <br />BLOCK WALL <br />1/4" <br />10" <br />10 <br />" <br />6" <br />2" <br />4"1 1/2" <br />4" <br />1 <br />1 <br />/ <br />2 <br />" <br />1 1/2" <br />27 <br />D-3 <br />1/2"Ø x 4 1/2" EMBED. HOT DIPPED GALVANIZED <br />THREADED STEEL ROD. DRILL 5/8"Ø HOLE & FILL <br />WITH "HILTI" HIT HY-270 ADHESIVE. <br />(4" MINIMUM EDGE DISTANCE) <br />(ICC ESR-4143). **SPECIAL INSPECTION <br />REQUIRED. CONTRACTOR TO AVOID CUTTING <br />OR DAMAGING WALL REINFORCING. <br />3/8" THICK GUSSET <br />N.T.S. <br />SCALE:CHAIN LINK SUPPORT AND BRACKET <br />GALVANIZED STEEL PIPES <br />SHOWN DASHED FOR CLARITY <br />9/16"Ø HOLES <br />1/4" THICK GALVANIZED <br />STEEL BENT PLATE <br />1/2"Ø GALVANIZED <br />STEEL PIPE CLAMP <br />CONCRETE <br />BLOCK WALL10" <br />4"4 1/2"1 1/2" <br />1' <br />- <br />4 <br />" <br />1 <br />1 <br />/ <br />2 <br />" <br />1' <br />- <br />1 <br />" <br />3" <br />3" <br />10 <br />" <br />1/4" <br />27 <br />D-3 <br />1/2"Ø x 4 1/2" EMBED. HOT DIPPED GALVANIZED THREADED STEEL <br />ROD. DRILL 5/8"Ø HOLE & FILL WITH "HILTI" HIT HY-270 ADHESIVE. <br />(4" MINIMUM EDGE DISTANCE) <br />(ICC ESR-4143). **SPECIAL INSPECTION REQUIRED. CONTRACTOR <br />TO AVOID CUTTING OR DAMAGING WALL REINFORCING. <br />3/8" THICK GUSSET <br />CABINET AND EQUIPMENT <br />MOUNTING FLANGE <br />CONCRETE SLAB & <br />REINFORCING PER <br />PLAN <br />VERIZON EQUIPMENT <br />EQUIPMENT FRAME TO SLAB <br />"HILTI" 1/2"Ø STAINLESS STEEL KWIK BOLT <br />TZ2 ANCHOR WITH 3-3/4" EMBED INTO <br />1/2"Ø HOLE DRILLED 4-1/2" DEEP. <br />SPECIAL INSPECTION REQUIRED (ICC <br />ELC-4266). <br />WARNING SIGN <br />WARNING <br />THIS FACILITY CONTAINS: <br />CORROSIVE LIQUID <br />(1) ONE WATER <br />REACTIVE LIQUID. <br />APPLY NO WATER <br />NOTE: <br />1.WARNING SIGN TO BE MOUNTED AT LOCATIONS SHOWN ON DETAIL <br />2.LETTERING SHALL BE A MIN. 1" IN HEIGHT AND IN A COLOR WHICH <br />CONTRASTS FROM THE SIGN BACKGROUND. <br />13 <br />" <br />15" <br />34 <br />D-3 <br />N.T.S. <br />SCALE: <br />23 <br />D-2 <br />36 <br />D-3 <br />22 <br />D-2 <br />24 <br />D-2