Laserfiche WebLink
49 51 52 <br />60 <br />TELECOMMUNICATIONS PROJECT MANAGEMENT <br />16776 BERNARDO CENTER DRIVE, UNIT 203 <br />SAN DIEGO, CA 92128 <br />15 <br />5 <br />0 <br />5 <br /> <br />S <br />A <br />N <br />D <br /> <br />C <br />A <br />N <br />Y <br />O <br />N <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br />, <br /> <br />B <br />L <br />D <br />G <br /> <br />C <br />. <br />IR <br />V <br />I <br />N <br />E <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />1 <br />8 <br />SHEET TITLE: <br />ISSUE STATUS <br />DATEREV.DESCRIPTION BY <br />FI <br />S <br />H <br />E <br />R <br /> <br />F <br />L <br />O <br />R <br />A <br />L <br />26 <br />7 <br />7 <br /> <br />3 <br />/ <br />4 <br /> <br />N <br />. <br /> <br />M <br />A <br />I <br />N <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />W <br />C <br />C <br />0 <br />1 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />0 02/28/2024 90% CD REVIEW jd <br />1 03/15/2024 90% CD DRM COMMENTS jd <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />03/29/2024 <br />05/17/2024 <br />06/21/2024 <br />08/01/2024 <br />09/25/2024 <br />05/07/2025 <br />06/04/2025 <br />90% CD DRM COMNTS #2 <br />100% FINAL CD <br />REVISED DIESEL TANK <br />REGULATORY HEIGHT <br />BP SUBMITTAL <br />100% CD BP PLANCHECK <br />STRUCT PLANCHECK <br />jd <br />jd <br />rl <br />jd <br />jd <br />jd <br />JD <br />D-5 <br />PROPRIETARY INFORMATION <br />THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS <br />IS PROPRIETARY TO VERIZON WIRELESS <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />I <br />. <br />D <br />. <br /> <br />1 <br />5 <br />8 <br />6 <br />1 <br />0 <br />6 <br />7 <br />Ren. 4-30-27 <br />No. C 11978 <br />LICENSED A RCHITECT <br />STATE OF CALIFORNIA <br />WILLIAM M. BOOTH <br />DETAILS <br />54 <br />57 58 <br />50 <br />53 <br />RF SCREEN FRAMING - PLAN <br />PER PLAN <br />FRP PANELS, TUBES, PLATES, <br />BOLTS, STUDS & NUTS <br />APPROVAL L.A.R.R. 25536 <br />(E) CONCRETE <br />BLOCK WALL <br />RF SCREEN FRAMING - PLAN <br />(N) 4" x 4" x 1/4" FRP HORIZONTAL <br />TUBE (TYPICAL) <br />(N) RF TRANSPARENT <br />SCREEN SHALL BE <br />DETAILED, PAINTED & <br />TEXTURED TO MATCH <br />(E) ADJACENT WALL <br />SURFACES <br />1/2"Ø FIBERGLASS <br />NUT & BOLT <br />(TYPICAL) <br />(N) 4" x 4" x 1/4" FRP <br />VERTICAL TUBE <br />(TYPICAL) <br />(N) 6 x 4 x 1/4" FRP <br />ANGLE (TYPICAL) <br />(N) 4" x 4" x 1/4" FRP <br />HORIZONTAL TUBE <br />(TYPICAL) <br />"HILTI" 1/2"Ø STAINLESS <br />STEEL KWIK BOLT TZ2 <br />MASONRY ANCHOR @ 24" <br />O.C. WITH 2-1/2" EMBED <br />INTO 1/2"Ø HOLE DRILLED <br />2-3/4" DEEP. SPECIAL <br />INSPECTION REQUIRED <br />(ICC ESR-4561) <br />SCALE: <br />56 <br />59RF SCREEN BOX SECTION <br />FRP PANELS, TUBES, PLATES, <br />BOLTS, STUDS & NUTS <br />APPROVAL L.A.R.R. 25536 <br />57 <br />D-5 <br />(N) 4 x 4 x 1/4" RF <br />TRANSPARENT ANGLE W/ <br />1/2"Ø FIBERGLASS NUT & <br />BOLT @ EACH END <br />(TYPICAL) <br />(N) RF TRANSPARENT <br />SCREEN SHALL BE <br />DETAILED, PAINTED & <br />TEXTURED TO MATCH <br />(E) ADJACENT WALL <br />SURFACES <br />(N) 6 x 4 x 1/4" FRP <br />ANGLE (TYPICAL) <br />1/2"Ø FIBERGLASS NUT <br />& THRU-BOLT (TYPICAL) <br />(N) 4" x 4" x 1/4" FRP <br />HORIZONTAL TUBE <br />(TYPICAL) <br />58 <br />D-5 <br />EQ <br />U <br />A <br />L <br />PE <br />R <br /> <br />P <br />L <br />A <br />N <br />EQ <br />U <br />A <br />L <br />PER PLAN <br />(N) 4" x 4" x 1/4" FRP <br />VERTICAL TUBE <br />(TYPICAL) <br />(E) CONCRETE <br />BLOCK PARAPET <br />WALL <br />PE <br />R <br /> <br />P <br />L <br />A <br />N <br />56 <br />D-5 <br />3/4" = 1'-0" <br />SCALE: <br />1" = 1'-0" <br />PER PLAN <br />(E) CONCRETE <br />PARAPET WALL <br />FRP PANELS, TUBES, PLATES, <br />BOLTS, STUDS & NUTS <br />APPROVAL L.A.R.R. 25536 <br />RF SCREEN FRAMING - SECTION <br />(N) 4" x 4" x 1/4" FRP <br />HORIZONTAL TUBE <br />(TYPICAL) <br />(N) 6 x 4 x 1/4" FRP <br />ANGLE (TYPICAL) <br />(N) 4" x 4" x 1/4" FRP <br />VERTICAL TUBE <br />(TYPICAL) <br />1/2"Ø FIBERGLASS NUT <br />& BOLT (TYPICAL) <br />PE <br />R <br /> <br />P <br />L <br />A <br />N <br />1/2"Ø FIBERGLASS NUT <br />& BOLT (TYPICAL) <br />(N) RF TRANSPARENT <br />SCREEN SHALL BE <br />DETAILED, PAINTED & <br />TEXTURED TO MATCH <br />(E) ADJACENT WALL <br />SURFACES <br />"HILTI" 1/2"Ø STAINLESS <br />STEEL KWIK BOLT TZ2 <br />MASONRY ANCHOR @ <br />24" O.C. WITH 2-1/2" <br />EMBED INTO 1/2"Ø HOLE <br />DRILLED 2-3/4" DEEP. <br />SPECIAL INSPECTION <br />REQUIRED (ICC <br />ESR-4561) <br />PANEL SEAM SCALE: <br />1" = 1'-0" <br />(N) 4 x 4 x 1/4" RF <br />TRANSPARENT ANGLE W/ <br />1/2"Ø FIBERGLASS NUT & <br />BOLT @ EACH END <br />(TYPICAL) <br />PER PLAN <br />FRP PANELS, TUBES, PLATES, <br />BOLTS, STUDS & NUTS <br />APPROVAL L.A.R.R. 25536 <br />(N) 4" x 4" x 1/4" FRP <br />HORIZONTAL TUBE <br />(TYPICAL) <br />1/2"Ø FIBERGLASS NUT <br />& BOLT (TYPICAL) <br />(N) 4" x 4" x 1/4" FRP <br />HORIZONTAL TUBE <br />(TYPICAL) <br />(N) 6 x 4 x 1/4" FRP <br />ANGLE (TYPICAL) <br />(N) 4" x 4" x 1/4" FRP <br />VERTICAL TUBE <br />(TYPICAL) <br />(N) RF TRANSPARENT SCREEN <br />SHALL BE DETAILED, PAINTED & <br />TEXTURED TO MATCH (E) <br />ADJACENT WALL SURFACES <br />PANEL SEAM <br />1" = 1'-0" <br />SCALE: <br />"HILTI" 1/2"Ø STAINLESS STEEL KWIK <br />BOLT TZ2 MASONRY ANCHOR @ 24" <br />O.C. WITH 2-1/2" EMBED INTO 1/2"Ø <br />HOLE DRILLED 2-3/4" DEEP. SPECIAL <br />INSPECTION REQUIRED (ICC ESR-4561) <br />(N) 4 x 4 x 1/4" RF TRANSPARENT <br />ANGLE W/ 1/2"Ø FIBERGLASS <br />NUT & BOLT @ EACH END <br />(TYPICAL) <br />N.T.S. <br />SCALE:FRP PANEL FRAMING - SECTION <br />FIBERGLASS SCREEN <br />(SHOWN SHADED) <br />PANEL SEAM <br />4" x 4" x 1/4" FIBERGLASS <br />HORIZONTAL TUBE <br />1/2"Ø FIBERGLASS <br />PLASTIC NUT & BOLT <br />6" x 4" x 1/4" FRP <br />ANGLE EACH SIDE OF <br />TUBE <br />FIBERGLASS SCREEN <br />(SHOWN SHADED) <br />4" x 4" x 1/4" FIBERGLASS <br />VERTICAL TUBE <br />(E) CONCRETE STEP <br />(N) 4" CONDUIT <br />2' <br />- <br />0 <br />" <br />TOP OF ROOF <br />(E) TOP OF PARAPET <br />(N) TOP OF RF SCREEN <br />(N) HYBRID CABLE(N) 1/4" THICK STEEL BOX <br />1'-0" <br />R2'- <br />0 <br />" <br />R2'- <br />0 <br />" <br />4'-6 1/2" <br />CABLE SHROUDCABLE SHROUD & CHASE <br />2'-3" <br />1'-3" <br />2'-6" <br />(E) PARAPET <br />(N) CABLE <br />TRAY <br />(N) HYBRID 6x12 <br />CABLE <br />(N) RF <br />SCREENING <br />(E) CONCRETE <br />STEP <br />TOP OF <br />ROOF <br />10"4' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />D-5 <br />52 <br />R2 <br />' <br />- <br />0 <br />" <br />R2'-0" <br />6' <br />- <br />7 <br />" <br />1'-3" <br />(N) 4" CONDUIT <br />(N) HYBRID 6x12 <br />CABLE <br />1/2" = 1'-0" <br />SCALE: <br />1/2" = 1'-0" <br />SCALE: <br />14 GA. SHEET METAL <br />COVER (GALV.) <br />(E) CONCRETE BLOCK <br />WALL <br />CABLES WITH <br />CLAMPS <br />#8 SELF-TAPPING SCREWS <br />INTO BENT PLATE <br />2" x 3" x 1/4" BENT PLATE <br />1/2"Ø GALVANIZED <br />MACHINE BOLT <br /> CABLE VERTICAL SUPPORT <br />CABLE VERTICAL SUPPORT <br />1'-2" <br />6" <br />1-5/8" P1000 GALVANIZED <br />UNISTRUT @ 48" O.C. <br />(E) CONCRETE BLOCK <br />WALL <br />1-5/8" P1000 GALVANIZED <br />UNISTRUT @ 48" O.C. <br />14 GA. SHEET METAL <br />COVER (GALV.) <br />CABLES WITH CLAMPS <br />2" <br />"HILTI" 3/8"Ø STAINLESS STEEL KWIK <br />BOLT TZ2 MASONRY ANCHOR WITH <br />1-1/2" EMBED INTO 7/16"Ø HOLE <br />DRILLED 2" DEEP. SPECIAL <br />INSPECTION REQUIRED (ICC <br />ESR-4561) <br />"HILTI" 3/8"Ø STAINLESS <br />STEEL KWIK BOLT TZ2 <br />MASONRY ANCHOR WITH <br />1-1/2" EMBED INTO 7/16"Ø <br />HOLE DRILLED 2" DEEP. <br />SPECIAL INSPECTION <br />REQUIRED (ICC ESR-4561) <br />1" = 1'-0" <br />SCALE: <br />3" = 1'-0" <br />SCALE: <br />50 <br />D-5 <br />PER PLAN <br />(E) CONCRETE BLOCK WALL <br />(N) 4" x 4" x 1/4" FRP <br />VERTICAL TUBE <br />(TYPICAL) <br />1/2"Ø FIBERGLASS <br />NUT & BOLT <br />(TYPICAL) <br />(N) 4 x 4 x 1/4" RF <br />TRANSPARENT ANGLE W/ <br />1/2"Ø FIBERGLASS NUT & <br />BOLT @ EACH END <br />(TYPICAL) <br />(N) 4" x 4" x 1/4" FRP <br />HORIZONTAL TUBE <br />(TYPICAL) <br />(N) 6 x 4 x 1/4" FRP <br />ANGLE (TYPICAL) <br />FRP PANELS, TUBES, PLATES, <br />BOLTS, STUDS & NUTS <br />APPROVAL L.A.R.R. 25536 <br />"HILTI" 1/2"Ø STAINLESS STEEL KWIK BOLT TZ2 <br />MASONRY ANCHOR @ 24" O.C. WITH 2-1/2" EMBED <br />INTO 1/2"Ø HOLE DRILLED 2-3/4" DEEP. SPECIAL <br />INSPECTION REQUIRED (ICC ESR-4561) <br />RF SCREEN FRAMING - PLAN 1" = 1'-0" <br />SCALE: <br />PER PLAN <br />(E) CONCRETE <br />WALL <br />(N) 4 x 4 x 1/4" RF <br />TRANSPARENT ANGLE <br />W/ 1/2"Ø FIBERGLASS <br />NUT & BOLT @ EACH <br />END (TYPICAL) <br />(N) 4" x 4" x 1/4" FRP <br />VERTICAL TUBE <br />(TYPICAL) <br />(N) 6 x 4 x 1/4" FRP <br />ANGLE (TYPICAL) <br />1/2"Ø FIBERGLASS <br />NUT & BOLT <br />(TYPICAL) <br />(N) RF TRANSPARENT <br />SCREEN SHALL BE <br />DETAILED, PAINTED & <br />TEXTURED TO MATCH <br />(E) ADJACENT WALL <br />SURFACES <br />RF SCREEN FRAMING - SECTION 1" = 1'-0" <br />SCALE: <br />"HILTI" 1/2"Ø STAINLESS <br />STEEL KWIK BOLT TZ2 <br />MASONRY ANCHOR @ <br />24" O.C. WITH 2-1/2" <br />EMBED INTO 1/2"Ø HOLE <br />DRILLED 2-3/4" DEEP. <br />SPECIAL INSPECTION <br />REQUIRED (ICC <br />ESR-4561) <br />FRP PANELS, TUBES, PLATES, <br />BOLTS, STUDS & NUTS <br />APPROVAL L.A.R.R. 25536 <br />FRP PANELS, TUBES, PLATES, <br />BOLTS, STUDS & NUTS <br />APPROVAL L.A.R.R. 25536 <br />REMOVABLE McNICHOLS <br />MS-M-150 MINI GRID FRP <br />GRATING (3/4" SQ. GRID) <br />McNICHOLS MS-M-150 MINI <br />GRID FRP GRATING (3/4" <br />SQ. GRID)