Laserfiche WebLink
TELECOMMUNICATIONS PROJECT MANAGEMENT <br />16776 BERNARDO CENTER DRIVE, UNIT 203 <br />SAN DIEGO, CA 92128 <br />15 <br />5 <br />0 <br />5 <br /> <br />S <br />A <br />N <br />D <br /> <br />C <br />A <br />N <br />Y <br />O <br />N <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br />, <br /> <br />B <br />L <br />D <br />G <br /> <br />C <br />. <br />IR <br />V <br />I <br />N <br />E <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />1 <br />8 <br />SHEET TITLE: <br />ISSUE STATUS <br />DATEREV.DESCRIPTION BY <br />FI <br />S <br />H <br />E <br />R <br /> <br />F <br />L <br />O <br />R <br />A <br />L <br />26 <br />7 <br />7 <br /> <br />3 <br />/ <br />4 <br /> <br />N <br />. <br /> <br />M <br />A <br />I <br />N <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />W <br />C <br />C <br />0 <br />1 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />0 02/28/2024 90% CD REVIEW jd <br />1 03/15/2024 90% CD DRM COMMENTS jd <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />03/29/2024 <br />05/17/2024 <br />06/21/2024 <br />08/01/2024 <br />09/25/2024 <br />05/07/2025 <br />90% CD DRM COMNTS #2 <br />100% FINAL CD <br />REVISED DIESEL TANK <br />REGULATORY HEIGHT <br />BP SUBMITTAL <br />BP PLANCHECK <br />jd <br />jd <br />rl <br />jd <br />jd <br />jd <br />A-0.3 <br />PROPRIETARY INFORMATION <br />THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS <br />IS PROPRIETARY TO VERIZON WIRELESS <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />I <br />. <br />D <br />. <br /> <br />1 <br />5 <br />8 <br />6 <br />1 <br />0 <br />6 <br />7 <br />Ren. 4-30-27 <br />No. C 11978 <br />LICENSED A RCHITECT <br />STATE OF CALIFORNIA <br />WILLIAM M. BOOTH <br />SPECIFICATIONS, RFDS & <br />ANTENNA SCHEDULE <br />ANTENNA & CABLE SCHEDULE <br />1.ALL ANTENNAS AND CABLE SHALL BE FURNISHED & INSTALLED BY THE CONTRACTOR. <br />2.VERIFY MODEL NUMBERS OF ANTENNAS WITH THE RFDS AND THE CONSTRUCTION MANAGER. <br />3.CONTRACTOR TO PROVIDE ALL CONNECTORS AND ANCILLARY EQUIPMENT INCLUDING <br />WEATHERIZATION, GROUND KITS, ETC.. <br />4.CONTRACTOR SHALL PROVIDE ALL CONDUIT, CABLE TRAY, GROUNDS, ETC. FOR COMPLETE <br />INSTALLATION OF ANTENNAS AND CABLES SHOWN AND INTENDED AS REQUIRED FOR A COMPLETE <br />OPERATING SYSTEM IN ACCORDANCE WITH CARRIER STANDARDS. <br />5.CONTRACTOR TO PROVIDE ALL LABOR TO INSTALL ANTENNAS, CABLE, AND EQUIPMENT. <br />6.CONTRACTOR SHALL COLOR CODE ALL CABLE. COLORED BANDS OF TAPE ON CABLE SHALL <br />IDENTIFY SECTOR, FREQUENCY, TECHNOLOGY, AND TRANSMIT GROUP AS FOLLOWS ON ALL CABLE <br />MODIFIED OR INSTALLED. <br />7.WHEN ANTENNA LINES ARE DIPLEXED, THE COLOR CODE OF THE HIGHEST FREQUENCY PREVAILS <br />(I.E. UMTS DIPLEXED WITH TDMA SHOULD HAVE COLOR 4 BANDS) <br />8.PRIOR TO PLACEMENT OF ANTENNA POLE MOUNTS, THE CONTRACTOR SHALL VERIFY THAT THE <br />AZIMUTH AND DIMENSIONS SHOWN ON THE PLANS MATCH ACTUAL FIELD CONDITIONS. ALLOWABLE <br />TOLERANCE: HORIZONTAL ALIGNMENT = ±5°; VERTICAL ALIGNMENT = ±1°. ALL AZIMUTHS SHALL <br />MATCH RFDS <br />9.IN NO CASE SHALL THERE BE ANY MORE THAN TWO (2) 90° TURNS (OR EQUIVALENT) IN ANY <br />CONTINUOUS LENGTH OF CONDUIT BETWEEN PULL BOXES OR SIMILAR FEATURES. <br />10.CABLE CONDUIT SHALL BE AS SHOWN ON PLANS. ALL UNDERGROUND CONDUIT SHALL BE <br />SCHEDULE 40 PVC. ALL EXPOSED CONDUIT ABOVE GRADE LEVEL SHALL BE IMC OR RIGID <br />GALVANIZED. ALL EXPOSED CONDUIT PROTECTED IN A BUILDING OR ON A ROOF SHALL BE EMT OR <br />UV STABILIZED PAINTED SCHEDULE 80 PVC <br />11.CABLE CONDUIT SHALL ONLY INCLUDE FACTORY-MADE LARGE RADIUS SWEEPS AT ALL CHANGES IN <br />DIRECTION. SWEEP RADIUS SHALL BE 24" MINIMUM ABOVE GROUND AND 48" MINIMUM BELOW <br />GROUND. <br />12.IN HIGH TRAFFIC AREAS OR WHERE SUSCEPTIBLE TO DAMAGE, CONTRACTOR SHALL PROVIDE <br />FORMED 14 GA. GALVANIZED SHEET METAL COVERS OVER CABLE ROUTES. WHERE CABLE IS RUN <br />ON THE WALL, ATTACH UNISTRUT TO WALL AND COVER WITH 14 GA. GALVANIZED FORMED SHEET <br />METAL COVER OR MATERIAL AS DIRECTED BY THE CONSTRUCTION MANAGER <br />13.VERIFY ROUTE AND LENGTH OF CABLE PRIOR TO CUTTING. ADJUST INDICATED ROUTE AS <br />REQUIRED TO CLEAR (E) EQUIPMENT AT FACILITIES <br />14.THE CONTRACTOR SHALL TEST ALL ANTENNAS AND SHALL PROVIDE DOCUMENTATION TO THE <br />CONSTRUCTION MANAGER <br />15.THE CONTRACTOR SHALL VERIFY ALL BOLT TORQUE TOLERANCES PER THE MANUFACTURERS <br />SPECIFICATIONS AND RECOMMENDATIONS <br />16.GROUND ALL (N) ANTENNAS, (N) EQUIPMENT MOUNTS AND (N) COAX PER SHEETS E-4, E-5 & E-6. <br />ANTENNA NOTES <br />PER SECTOR <br />OF CABLES <br />& SIZE <br />CABLE <br />(+ / - 5') <br />LENGTH <br />50'-0" <br />AZIMUTHSECTORDIRECTION <br />ANTENNA AND CABLE SCHEDULE <br />BETA4 <br />BETA3 <br />BETA2 <br />BETA1 <br />200° <br />EAST 110° <br />ANTENNA <br />ALPHA4 <br />ALPHA3 <br />ALPHA2 <br />ALPHA1 <br />SOUTH <br />1 HYBRID <br />6 x 12 <br />MODEL <br />NOTES: <br />INSTALL (1) 6 x 12 HYBRID CABLE FOR EACH SECTOR (3 TOTAL) <br />INSTALL (1) DEMARCATION JUNCTION BOX (RAYCAP SURGE SUPPRESSOR) PER SECTOR (3 TOTAL) <br />INSTALL (3) ANTENNAS: ERICSSON KRE105281/1: 8.4" LENGTH x 7.9" WIDE x 4.9" DEEP, WEIGHT: 11.02 LBS <br />INSTALL (6) ANTENNAS: COMMSCOPE NHH-65C-R2B: 96.0" LENGTH x 11.9" WIDE x 7.1" DEEP, WEIGHT: 51.6 LBS <br />INSTALL (3) ANTENNAS: ERICSSON AIR 6419: 31.3" LENGTH x 16.1" WIDE x 9.8" DEEP, WEIGHT: 88.0 LBS <br />INSTALL (2) RRU UNITS PER SECTOR, TOTAL OF (6) RRU UNITS <br />1 <br />2 <br />3 <br />4 <br />1 <br />2 <br />NUMBERSIZERRU UNITS DOWNTILT <br />0° <br />RAYCAP <br />4 3 <br />UNITS <br />4490 45'-1" <br />RAD <br />CENTER <br />1 <br />1 <br />GAMMA4 <br />GAMMA3 <br />GAMMA2 <br />GAMMA1 <br />330°NORTH 1 <br />RRU UNITS AT KRE105281/1 ANTENNAS ARE INTEGRAL5 <br />5 <br />ERICSSON: KRE105281/1 <br />COMMSCOPE: NHH-65B-R2B <br />ERICSSON: AIR 6419 <br />8.4" L x 7.9" W x 4.9" D <br />72.0" L x 11.9" W x 7.1" D <br />31.3" L x 16.1" W x 9.8" D 0°INTEGRAL W/ <br />ANTENNA 46'-9" <br />4408 B48 DC <br />(INTEGRAL)0°47'-8" <br />0°4490 <br />0° <br />0°4490 <br />0° <br />0° <br />0° <br />44'-1" <br />46'-9" <br />46'-9" <br />240'-0" <br />300'-0" <br />COMMSCOPE: NHH-65B-R2B 0°4890 <br />ERICSSON: AIR 6419 31.3" L x 16.1" W x 9.8" D <br />ERICSSON: KRE105281/1 8.4" L x 7.9" W x 4.9" D <br />4890 <br />4408 B48 DC <br />(INTEGRAL)47'-8" <br />0° <br />0° <br />ERICSSON: AIR 6419 <br />ERICSSON: KRE105281/1 <br />31.3" L x 16.1" W x 9.8" D <br />8.4" L x 7.9" W x 4.9" D 4408 B48 DC <br />(INTEGRAL) <br />4890 <br />47'-8" <br />72.0" L x 11.9" W x 7.1" D <br />1 HYBRID <br />6 x 12 <br />1 HYBRID <br />6 x 12 <br />COMMSCOPE: NHH-45C-R2B 95.9" L x 18.0" W x 7.0" D <br />COMMSCOPE: NHH-45C-R2B 95.9" L x 18.0" W x 7.0" D <br />COMMSCOPE: NHH-45C-R2B 95.9" L x 18.0" W x 7.0" D <br />COMMSCOPE: NHH-45C-R2B 95.9" L x 18.0" W x 7.0" D <br />3 <br />4 <br />D-1 <br />9 <br />D-1 <br />10 <br />D-1 <br />6 <br />D-1 <br />7 <br />D-1 <br />1 <br />D-1 <br />2 <br />D-1 <br />3 <br />D-1 <br />INTEGRAL W/ <br />ANTENNA <br />INTEGRAL W/ <br />ANTENNA <br />45'-1" <br />44'-1" <br />44'-1" <br />44'-1"