Laserfiche WebLink
RESTRICTIVE NOTICE <br />DATE REVISIONS <br />SHEET DESCRIPTION <br />PROJECT OWNER <br />PROJECT ADDRESS <br />STAMP <br />NO: <br />REVISIONS <br />DATE SIGNED: 2/17/25 <br />THESE DESIGNS, DRAWINGS, AND <br />SPECIFICATIONS ARE THE EXCLUSIVE <br />PROPERTY OF DONG ENGINEERING. <br />THESE DRAWINGS CANNOT BE COPIED, <br />TRANSFERRED, OR REPRODUCED NOR <br />CAN ANY OTHER STRUCTURES BE BUILT <br />FROM THEM WITHOUT WRITTEN CONSENT. <br />SHEET <br />DE#: <br />TEL- 714-617-5979 <br />GARDEN GROVE, CA 92841 <br />7661 GARDEN GROVE BLVD., <br />DONG ENGINEERING, INC. <br />INFO@DONGENGINEERING.COM <br />240140 <br />GA <br />R <br />A <br />G <br />E <br /> <br />C <br />O <br />N <br />V <br />E <br />R <br />T <br /> <br />T <br />O <br /> <br />A <br />D <br />U <br />26 <br />1 <br />7 <br /> <br />D <br />E <br />O <br />D <br />A <br />R <br /> <br />S <br />T <br />, <br /> S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />SD2 <br />STRUCTURAL DETAILS <br />1ROOF TRUSS BY MFR., SEE PLAN.ROOF~13 <br />22X BLK'G @ 48" O.C.WALL~73SIMPSON "DTC" @ 48" O.C. MAX.H-DTC~ <br />4JOIST OR TRUSS BOTT. CHORD.4JOIST OR TRUSS BOTT. CHORD. <br />3SIMPSON "DTC" @ 48" O.C. MAX.H-DTC~ <br />5NON BEARING WALL. <br />3/ <br />4 <br />" <br />, <br /> <br />T <br />Y <br />P <br />. <br />3/ <br />4 <br />" <br />, <br /> <br />T <br />Y <br />P <br />. <br />5NON BEARING WALL. <br />1. ROOF OR FLOOR SYSTEM OR TRUSSES BY MFR., SEE PLAN. <br />2. 2X BLK'G @ 48" O.C. <br />3. SIMPSON "DTC" @ 48" O.C. MAX. <br />4. JOIST OR TRUSS BOTT. CHORD. <br />5. NON BEARING WALL. <br />111 <br />NON-BEARING WALL DETAIL <br />2-0" MIN. <br />PANEL WIDTH <br />1SHEARWALL PER PLAN, REFERS TO SHEARWALL SCHEDULE. <br />2EDGE NAIL (E.N.) SHEAR PANEL TO ALL PANEL EDGES. <br />3FIELD NAIL @ 12" O.C. <br />4KING STUD OR POST PER PLAN. E.N. SHEAR PANEL TO POST. <br />5TRIMMER WHERE OCCURS. <br />8INSTALL HOLDOWN ON KING STUD OR POST W/ EDGE NAILING. <br />1. SHEAR PANEL PER PLAN. <br />2. EDGE NAIL (E.N.) SHEAR <br />PANEL TO ALL SHEARWALL <br />EDGES. <br />WHEN PANEL EXTEND TO <br />TRIMMER, E.N. BOTH TRIMMER <br />AND KING STUDS. <br />3. FIELD NAIL @ 12" O.C. <br />4. 2X OR MULTIPLE KING STUD <br />PER FRAMING NOTE W/ 16d <br />@ 16" O.C. TO TRIMMER. <br />5. TRIMMER PER PLAN. <br />6. HEADER PER PLAN. <br />7. MIN. 3-16d TO END OF HEADER. <br />8. SIMPSON HOLDOWN <br />PER PLAN. <br />9.WHEN HOLDOWNS <br />CONNECTED TO KING STUD, <br />REPLACED SDS SCREWS W/ <br />LONGER LENGTH TO GET 2 1/2" <br />PENETRATIONS TO TRIMMER.NOTES: <br />1. PROVIDE 3/8" EDGE DISTANCE FOR NAILS. <br />2. PROVIDE MIN. 2X BLK'G @ ALL PLYWOOD EDGES OR AS NOTED IN SHEAR SCHULE. <br />3. STAGGER NAILS THAT ARE SPACED 2" O.C. <br />4. FOR SPECIFIC SHEARWALL CONDITIONS, SEE PLAN & SCHEDULE. <br />5. NO CUTS OR HOLES IN SHEATHING WITHIN 16" OF CORNERS. <br />6. MAX. ACCUMULATED LENGTH OF OPENINGS SHALL NOT EXCEED 20% OF THE WALL <br />LENGTH. MAX. LENGTH OF EA. OPENING IS 4-1/2" IN ANY DIRECTION. <br />6TRIMMER WHERE OCCURS. <br />7KING STUD OR POST PER PLAN. E.N. SHEAR PANEL TO POST. <br />9INSTALL HOLDOWN ON KING STUD OR POST W/ EDGE NAILING. <br />111 <br />SHEAR PANEL ASSEMBLY DETAIL <br />1BEAM PER PLAN. <br />1BEAM PER PLAN.1BEAM PER PLAN. <br />2DBL. TOP PLATE. <br />2DBL. TOP PLATE.2DBL. TOP PLATE.3SIMPSON STRAP MSTI36 OR ST6224 3SIMPSON STRAP MSTI36 OR ST6224 <br />4SIMPSON (2)A35 @ TOP & BOTT. <br />4SIMPSON (2)A35 @ TOP & BOTT. <br />4SIMPSON (2)A35 @ TOP & BOTT. <br />5POST OR MULTI STUD PER PLAN.WALL~3 <br />5POST OR MULTI STUD PER PLAN.5POST OR MULTI STUD PER PLAN. <br />6(3)16d EA. SIDE <br />6(3)16d EA. SIDE <br />7SILL PLATE. <br />1. BEAM PER PLAN. <br />2. DBL. TOP PLATE. <br />3. SIMPSON STRAP MSTI36 <br />OR ST6224. <br />4. SIMPSON A34 AT EA. <br />SIDE OF BEAM AND POST <br />PER BEAM CONDITION. <br />5. POST OR MULTI STUD <br />PER PLAN. <br />6. 2X STUD EA. SIDE OF <br />BEAM W/ 16d @ 12" O.C. <br />STAGGERED TO POST. <br />ADD 3-16d EA. SIDE TO BM. <br />7. 2X SILL PLATE. <br />NOTE: <br />- ADD FILLER @ SIDE OF <br />BEAM AS NEEDED. <br />1BEAM PER PLAN. <br />2DBL. TOP PLATE.4SIMPSON (2)A35 @ TOP & BOTT. <br />4SIMPSON (2)A35 @ TOP & BOTT. <br />4SIMPSON (2)A35 @ TOP & BOTT. <br />5POST OR MULTI STUD PER PLAN.WALL~3 <br />7SILL PLATE. <br />COND A: DROP BEAM COND B: TOP FLUSH BEAM <br />COND C: BOTTOM FLUSH BEAM COND D: SIDE FLUSH BEAM <br />111 <br />BEAM POCKET DETAIL <br />111 <br />TOP PLATE SPLICE TYP. <br />SEE TABLE <br />NAIL SPLICE: <br />STRAP SPLICE: <br />1FLOOR SYSTEM PER PLAN.FLOOR~7 <br />2FLOOR SYSTEM PER PLAN.FLOOR~7 <br />2FLOOR SYSTEM PER PLAN.FLOOR~7 <br />3FLOOR SYSTEM PER PLAN.FLOOR~7 <br />3FLOOR SYSTEM PER PLAN.FLOOR~7 <br />5FLOOR SYSTEM PER PLAN.FLOOR~7 <br />4FLOOR SYSTEM PER PLAN.FLOOR~74FLOOR SYSTEM PER PLAN.FLOOR~7 <br />2FLOOR SYSTEM PER PLAN.FLOOR~73FLOOR SYSTEM PER PLAN.FLOOR~7 <br />EQ.EQ. <br />EQ. <br />7FLOOR SYSTEM PER PLAN.FLOOR~7 <br />EQ. <br />1. 16d @ 8" O.C. (5) MIN. EA. SIDE OF <br />SPLICE U.N.O. & PER TABLE BELOW. <br />2. 2X STUD WALL PER PLAN. <br />3. LOCATE STUD UNDER SPLICE OR <br />PROVIDE 2X BLKG. ATTACHED TO <br />ADJACENT STUD W/ (3) 16d EA. SIDE. <br />4. PLATE TO STUD NAILING PER <br />C.B.C. MIN REQUIREMENTS. <br />5. NUMBER OF NAIL SPECIFIED <br />BETWEEN SPLICING POINTS PER <br />TABLE BELOW. <br />6. SIMP. STRAP PER TABLE BELOW. <br />7. SIMP. STRAP ST6224. <br />NOTES: <br />- FULLY NAIL STRAP W/ 16d <br />SINKER OR 10d COMMON. <br />- NAIL SHALL BE STAGGERED <br />& AT LEAST 2 1/4" APART. <br />CAPACITY 1880# <br />A <br />2506# <br />B <br />3760# <br />CCONDITION <br />MIN. PLATE LAP <br />COMMON NAIL <br />4' - 0" MIN. <br />1 ROW (9) - 16d <br />4' - 0" MIN. <br />2 ROW (6) - 16d <br />6' - 0" MIN. <br />2 ROW (9) - 16d <br />STRAP MSTA30 ST 6224 MST48 <br />NAIL <br />SPLICE <br />STRAP <br />SPLICE <br />6FLOOR SYSTEM PER PLAN.FLOOR~7 <br />6FLOOR SYSTEM PER PLAN.FLOOR~7 <br />℄ PANEL JOINT. <br />3/8" TYP. <br />℄ PANEL JOINT. <br />3/8" TYP. <br />OFFSET EDGE SUPPORT <br />OFFSET EDGE SUPPORT <br />1ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1 <br />1ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1 <br />2JOIST.32 x 4 W/ 16d @ 12" O.C. <br />42 x 4 FLAT W/ (2) 10d @ EA. END. <br />1. ROOF SHEATHING AND NAILING <br />PER NAILING SCHDL. <br />2. JOIST. <br />3. 2 x 4 W/ 16d @ 12" O.C. <br />4. 2 x 4 FLAT W/ (2) 10d @ EA. END. <br />111 <br />BLOCKING AT EDGE SUPPORT <br />"W <br />" <br /> <br />M <br />A <br />X <br />. <br />"L" MAX.12" MIN.12" MIN. <br />EQ <br />. <br />EQ <br />. <br />1NOTCH LOCATION.2SIMPSON STRAP "MSTA36" W/ (11) 10d COMMON EA. END (STRAP NOT REQ'D AT SILL PLT.)3BORED HOLE. <br />1. NOTCH LOCATION. <br />2. SIMPSON STRAP "MSTA36" W/ (11) <br />10d COMMON EA. END (STRAP NOT <br />REQ'D AT SILL PLT.) <br />3. BORED HOLE. <br />NOTE: <br />ONLY ONE NOTCH OR HOLE ALLOWED PER <br />EA. STUD. ( EXCLUDING LET-IN BRACES). <br />2-2X TOP PLT. <br />2X OR 3X <br />SILL PLATE. <br />NOTCHES <br />MIN. <br />SPACING <br />BORED <br />HOLES <br />"L" <br />MAX. <br />"W" <br />MAX. <br />2X4 PLATE <br />2X6 PLATE <br />2X8 PLATE <br />6'-0" <br />6'-0" <br />6'-0" <br />3-1/2" <br />5-1/2" <br />5-1/2" <br />1-1/2" <br />2" <br />2" <br />1-1/4" <br />2" <br />3" <br />111 <br />PLATE NOTCHING AND BORING <br />1PANEL BOUNDARY & BOUNDARY NAILING (B.N.) PER PLAN. <br />2FIELD NAILING PER PLAN.3CONTINUOUS PANEL EDGE, NO BLKG', E.N. PER PLAN. <br />1PANEL BOUNDARY & BOUNDARY NAILING (B.N.) PER PLAN. <br />4DISCONTINUOUS PANEL EDGE, E.N. PER PLAN. <br />5FRAMING @ 24" O.C. SHOWN (16" O.C. SIMILAR). <br />6DIRECTION OF FACE GRAIN PERPENDICULAR TO SUPPORT. <br />1. PANEL BOUNDARY & BOUNDARY <br />NAILING (B.N.) PER PLAN. <br />2. FIELD NAILING PER PLAN. <br />3. CONTINUOUS PANEL EDGE, NO <br />BLKG', E.N. PER PLAN. <br />4. DISCONTINUOUS PANEL EDGE, <br />E.N. PER PLAN. <br />5. FRAMING @ 24" O.C. SHOWN (16" <br />O.C. SIMILAR). <br />6. DIRECTION OF FACE GRAIN <br />PERPENDICULAR TO SUPPORT. <br />NOTES: <br />- STAGGER JOINTS AS SHOWN. <br />- MIN. SIZE OF SHEET SHALL BE <br />2 FT. x 2 FT. <br />- NAILS SHALL BE DRIVEN TIGHT <br />BUT SHALL NOT FRACTURE <br />SURFACE OF SHEATHING. <br />- TOLERANCE ON NAILING SHALL BE <br />3/4" W/ THE AVERAGE NAIL <br />SPACING OVER ANY 4 FT. LENGTH <br />BEING AT LEAST THAT NOTED ON <br />THE PLAN. <br />111 <br />PLYWOOD SHEATHING LAYOUT <br />111 <br />TYPICAL HEADER DETAIL <br />1HDR. PER PLAN.WALL~4 <br />2(3) 16d COMMON FROM KING STUD TO HEADER, TYP. <br />3SIMPSON A35 @ T&B EA. END OF HEADER AT ALL EXTERIOR WALLS AT OPENINGS WIDER THAN 8'-0" <br />4SIMPSON LTP4 ALT. TO A35. INSTALL EA. SIDE OF HEADER. <br />5(2) 16d @ 2X4 WALL, (3) 16d @ 2X6 & 2X8 WALL. <br />1. HDR. PER PLAN. <br />2. (3) 16d COMMON FROM KING STUD TO HEADER, TYP. <br />3. SIMPSON A35 @ T&B EA. END OF HEADER AT ALL EXTERIOR <br />WALLS AT OPENINGS WIDER THAN 8'-0" <br />4. SIMPSON LTP4 ALT. TO A35. INSTALL EA. SIDE OF HEADER. <br />5. (2) 16d @ 2X4 WALL, (3) 16d @ 2X6 & 2X8 WALL. <br />± <br />±C.L. <br />4 2 <br />53 <br />1 <br />6 <br />ALT. TO VENT BLOCK <br />TYP.MAX. <br />± <br />± <br />C.L. <br />4 2 <br />TYP. <br />MAX. <br />1. TYP. EDGE NAILING. <br />2. FOR VENT SPACING OF 6'-0" <br />(2-A35's PER ADJACENT BLK's.), <br />AND FOR VENT SPACING OF <br />4'-0" (3-A35's PER ADJACENT <br />BLK's.). SKIP A35's @ VENT <br />BLOCKING. <br />3. SCREEN FOR VENTILATION. <br />4. 8d COMMON EDGE NAILS : <br />@ 4" O.C. FOR VENT <br />SPACING OF 6'-0". <br />@ 3" O.C. FOR VENT <br />SPACING OF 4'-0". <br />5. ADJOINING FULL HT. <br />BLOCKING PER SHEAR <br />TRANSFER DETAILS. <br />6. (3) BAYS OF FLAT BLK'G. <br />CENTERED @ SCREEN. <br />111 <br />TYPICAL VENT BLOCK <br />ROOF TRUSS CONDITION <br />ROOF CONVENTIONAL CONDITION <br />111 <br />FIELD FIX FOR OPENING IN S.W. <br />2 <br />1 <br />3 <br />4 <br />1' <br />- <br />4 <br />" <br />1'-4" <br />4" <br />5 <br />NOTE: <br />- AVOID OPENING IN SHEAR WALLS W/ <br />LENGTH LESS THAN 4'-0". <br />- MAX. WIDTH OF OPENING TO BE ONE <br />STUD BAY OR 14 1/2". DO NOT OVER-CUT <br />ANY FRAMING MEMBER. <br />- E.N. TO BLK'G. TO MATCH SHEAR WALL <br />E.N. UNLESS STRAP IS PLACED ON TOP <br />OF PLYWOOD. <br />- E.N. F.HT. ALONG STUD ON EACH SIDE <br />OF OPENING. <br />- IF OPENING IS LOCATED AT THE EDGE, <br />EXTEND STRAP INTO THE SHEAR WALL <br />TO MEET MIN. LENGTH REQUIRED. <br />1. 2X BLOCKING <br />2. SIMP. CS16X48" LONG W/ NAILS <br />@ 2-1/16" O.C. <br />3. ALT. LOCATION OF OPENING IF CONT. <br />SILL PLATE, NO "CS" STRAP REQUIRED <br />@ BOTTOM. <br />4. NO CUT OR HOLES IN SHT'G WITHIN <br />16" OF CORNERS. <br />5. OPENINGS OF MAX. 4 1/2"x4 1/2" DO <br />NOT NEED BLK'G/STRAP. DO NOT CUT <br />MORE THAN ONE OPENING IN ONE <br />HORIZONTAL LINE (AT ONE ELEVATION) <br />AND OFFSET OPENINGS BY MIN. 4" <br />VERT. SEE DETAIL 1/SN2 FOR <br />OPENINGS SMALLER THAN 4 1/2" x 4 1/2" <br />111 <br />SHEAR TRANSFER <br />12X STUD PER PLAN.Wall~1 <br />22X ROOF RAFTER PER PLAN.Roof~2 <br />32X CEILING JOIST PER PLAN.Roof~3 <br />4ROOF SHEATHING AND NAILING PER NAILING SCHDL.Roof~1 <br />6SHEARWALL PER PLAN.Wall~2 <br />7FRAMING CLIP A35 PER SHEARWALL SCHDL. @ 48" O.C. MAX.A-A35_L~1 <br />8BOUNDARY NAILS.N-10d~ <br />8BOUNDARY NAILS.N-8d~ <br />1. (E) 2X STUD WALL. <br />2. (E) 2X ROOF RAFTER PER PLAN. <br />3. (N) 2X CEILING JOIST WHERE OCCURED. <br />4. (E) ROOF SHEATHING. <br />5. (E) DBL. TOP PLATE OR DROP BM PER PLAN. <br />6. (N) SHEARWALL WHERE OCCURRED. <br />7. (N) FRAMING CLIP A35 PER SHEARWALL <br />SCHDL. @ 48" O.C. MAX. <br />8. BOUNDARY NAILS. <br />9. (N) 6-16d COMMON NAILS @ EA. RAFTER AND <br />(N) CEILING JOIST. <br />5DBL. TOP PLATE OR DROP BM. PER PLAN.WALL~6 <br />96-16d COMMON NAILS @ EA. RAFTER AND CEILING JOIST.ROOF~11 <br />111 <br />SHEAR TRANSFER <br />12X ROOF RAFTER PER PLAN.ROOF~2 <br />22X CEILING JOIST PER PLAN.ROOF~3 <br />32X CEILING JOIST OR BLK'G <br />42X STUD WALL PER PLAN.WALL~1 5(N) SHEARWALL WHERE OCCUR <br />6FRAMING CLIP LTP4 PER SHEARWALL SCHDL. @ 48" O.C. MAX.A-LTP4_BEND~1 <br />7PROVIDE 2X STRUT @ 48" O.C. W/ A35 @ EA. END. <br />82 x 4 FLAT SPAN ACROSS MIN. 6 C.J. @ 8'-0" MAX. <br />9DBL. TOP PLATE.W-22X4~ <br />10ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1 <br />1. (E) 2X ROOF RAFTER <br />PER PLAN. <br />2. (N) 2X CEILING JOIST <br />PER PLAN. <br />3. (E) 2X BLK'G <br />4. (E) 2X STUD WALL PER PLAN. <br />5. (N) SHEARWALL PER PLAN <br />WHERE OCCUR. <br />6. FRAMING CLIP LTP4 PER <br />SHEARWALL SCHDL. <br />@ 48" O.C. MAX. <br />7. (E) 2X STRUT @ 48" O.C. <br />8. (N) 2 x 4 FLAT SPAN ACROSS <br />MIN. 6 C.J. @ 8'-0" MAX. <br />9. (E) DBL. TOP PLATE OR <br />DROP BM. PER PLAN. <br />10. (E) ROOF SHEATHING AND <br />NAILING PER NAILING SCHDL. <br />11. BOUNDARY NAILS. <br />11BOUNDARY NAILS.N-8d~ <br />111 <br />CONNECTION DETAIL <br />1(E) 2X STUD WALL. <br />2(N) 2X STUD WALL PER PLAN. <br />3(E) STUCCO TO BE REMAINED. <br />5(E) DRYWALL TO BE REMAINED. <br />4(N) STUCCO MATCH W/ (E) STUCCO. <br />6(N) DRYWALL MATCH WITH (E) DRYWALL. <br />8(E) HDR. TO BE REMAINED. <br />7(N) 2X PLATE W/ 10d COMMON NAIL @ 6" O.C. TO (E) HDR. <br />92X SOLE PLATE W/ 16d @ 6" O.C. U.N.O., SEE NAILING PER SHEARWALL SCHDL.WALL~5 <br />1. (E) 2X STUD WALL. <br />2. (N) 2X STUD WALL PER <br />PLAN. <br />3. (E) STUCCO TO BE <br />REMAINED. <br />4. (N) STUCCO MATCH W/ (E) <br />STUCCO. <br />5. (E) DRYWALL TO BE <br />REMAINED. <br />6. (N) DRYWALL MATCH WITH <br />(E) DRYWALL. <br />7. (N) 2X PLATE W/ 10d <br />COMMON NAIL @ 6" O.C. TO <br />(E) HDR. <br />8. (E) HDR. TO BE REMAINED. <br />9. 2X SOLE PLATE W/ 16d @ 6" <br />O.C. U.N.O., SEE NAILING PER <br />SHEARWALL SCHDL. <br />12X ROOF RAFTER PER PLAN.Roof~2 <br />2ROOF SHEATHING AND NAILING PER NAILING SCHDL.Roof~1 <br />32X CEILING JOIST PER PLAN.Roof~342X STUD WALL PER PLAN.Wall~1 <br />5SHEARWALL PER PLAN.Wall~2 <br />62X LEDGER W/ 2-16d TO EA. STUDW-2X8~3 <br />72X BEVELED BLK'G.Roof~4 <br />8SIMPSON APPROVED HANGER PER PLAN.H-HU48_L~1 <br />9FRAMING CLIP A35 PER SHEARWALL SCHDL. @ 48" O.C. MAX.A-A35_L~1 <br />10SIMPSON HURRICANE CLIP H2.5A @ EA. TRUSS TO TOP PLATE.A-H2.5A_L~ <br />1. (E) 2X ROOF RAFTER PER PLAN. <br />2. (E) ROOF SHEATHING AND NAILING <br />PER NAILING SCHDL. <br />3. (N) 2X CEILING JOIST PER PLAN. <br />4. (E) 2X STUD WALL PER PLAN. <br />5. (N) SHEARWALL WHERE OCCURED. <br />6. (N) 2X LEDGER W/ 2-16d TO EA. STUD <br />7. 2X BEVELED BLK'G. <br />8. SIMPSON APPROVED HANGER PER <br />PLAN. <br />9. FRAMING CLIP A35 PER SHEARWALL <br />SCHDL. @ 48" O.C. MAX. <br />10. SIMPSON HURRICANE CLIP H2.5A <br />@ EA. RAFTER TO TOP PLATE. <br />11. BOUNDARY NAILS. <br />12. DBL. TOP PLATE OR DROP BM. PER <br />PLAN. <br />13. SHEARWALL ALT. LOCATION. <br />11BOUNDARY NAILS.N-10d~ <br />11BOUNDARY NAILS.N-8d~12DBL. TOP PLATE OR DROP BM. PER PLAN.WALL~6 <br />111 <br />SHEAR TRANSFER <br />13SHEARWALL ALT. LOCATION.