My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2617 N Deodar St & Unit# 2 - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Deodar St
>
2617 N Deodar St Unit# 2
>
2617 N Deodar St & Unit# 2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:48 AM
Creation date
2/13/2026 5:00:45 AM
Metadata
Fields
Template:
Plan
Permit Number
101119933
Full Address
2617 N Deodar St Unit# 2
Street Number
2617
Street Direction
N
Street Name
Deodar
Street Suffix
St
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
B24R <br />B21R <br />SB48 <br />B15R <br />B24R <br />B21R <br />SB48 <br />B15R <br />W1636R <br />W2136R <br />W2436R <br />W2724 <br />3040LS <br />W04W04 <br />W02W02 <br />W03W03 <br />W03W03 <br />D02D02 <br />W01W01 <br />D01D01 <br />D03D03 <br />D04D04 <br />31168 <br /> <br />30X22 <br />ATTIC <br />ACCESS <br />GFCIGFCI <br />GFCIGFCI <br />CO/SD <br />GFCIGFCI <br />GFCIGFCI <br />GFCIGFCI <br />GFCIGFCI <br />R <br />R <br />R <br />R <br />3 <br />GFCIGFCI <br />GFCIGFCI <br />GFCI <br />GFCI <br />VS <br />R <br />R <br />3 <br />EP <br />E5 <br />A8 <br />E5 <br />A8 <br />ELEVATION 5 <br />E1 <br />A6 <br />E1 <br />A6 <br />ELEVATION 1 <br />4'-2" <br />4' <br />4' <br />4' <br />2' <br />18'-2" <br />52'-2" <br />7'-4" <br />1'-10"9" <br />3' <br />7" <br />4'-4" <br />11'-4" <br />3'8'-4" <br />21'-1" <br />9'-1" <br />47'-1" <br />21' <br />1'-6" <br />30" <br />9'-3" X 11'-7" <br />8'-9" X 12'-4" <br />6'-0" X 8'-0" <br />1'-5" X 5'-5" <br />3'-0" X 6'-5" <br />BEDROOM 2 <br />BEDROOM 3 <br />BATH <br />LAUNDRY <br />CLOSET <br />VS <br />4X4 POST <br />N <br />DOOR SCHEDULE <br />NUMBER LABEL QTY FLOOR SIZE R/O DESCRIPTION U-FACTOR <br />D01 3068 1 1 3068 R EX 38"X83"EXT. HINGED-DOOR E21 0.3 <br />D02 2668 1 1 2668 R IN 32"X82 1/2"HINGED-DOOR P04 0.3 <br />D03 4068 1 1 4068 L/R 50"X82 1/2"4 DR. BIFOLD-LOUVERED 0.3 <br />D04 41068 1 1 41068 L/R 60"X82 1/2"4 DR. BIFOLD-LOUVERED 0.3 <br />WINDOW SCHEDULE <br />NUMBER LABEL QTY FLOOR SIZE R/O EGRESS DESCRIPTION U-FACTOR SHGC TEMPERED <br />W01 2030LS 1 1 2030LS 25"X37"LEFT SLIDING 0.3 0.23 YES <br />W02 2030RS 1 1 2030RS 25"X37"RIGHT SLIDING 0.3 0.23 <br />W03 4040LS 2 1 4040LS 49"X49"LEFT SLIDING 0.3 0.23 <br />W04 3030LS 1 1 3030LS 37"X37"LEFT SLIDING 0.3 0.23 <br />(E) EXTERIOR WALL <br />(N) EXTERIOR WALL <br />(E) INTERIOR WALL <br />(N) INTERIOR WALL A4 <br />SHEET: <br />SCALE: <br />DATE: <br />11/25/2024 <br />Revision Table <br />Number <br />Date <br />Revised By <br />Description <br />1 <br />10/27/2023 <br />JO <br />PLANNING <br />2 <br />01/31/2024 <br />JO <br />PLANNING <br />3 <br />03/08/2024 <br />JO <br />BP <br />4 <br />04/02/2024 <br />JO <br />PCC <br />5 <br />11/25/2024 <br />JO <br />PCC <br />COMPA'S DESIGN SERVICES <br />949 N. IROQUOIS AVE. <br />ANAHEIM, CA 92801 <br />JUAN ORELLANA _____________ <br />(N) ADU - FLOOR PLAN <br />SCALE: 1/2" = 1'-0" <br />(N) ADU FLOOR <br />PLAN <br />1.) EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE <br />OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING <br />HAVING A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET <br />EXCEPT FOR GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM <br />NET CLEAR OPENING OF 5 SQUARE FEET. THE MIN. NET CLEAR <br />OPENING HEIGHT SHALL BE 24 IN., WIDTH SHALL BE 20 IN. MIN., <br />AND BOTTOM OF THE CLEAR OPENING SHALL BE NO GREATER <br />THAN 44 INCHES MEASURED FROM THE FLOOR. PROVIDE <br />EMERGENCY ESCAPE AND RESCUE OPENING FOR EVERY <br />SLEEPING ROOM. CRC R310. SHOW THAT BEDROOM WINDOW <br />COMPLIES <br />2). “CARBON MONOXIDE ALARM SHALL BE INTERCONNECTED <br />HARD-WIRED WITH BATTERY BACKUP.” E. BATTERY CARBON <br />MONOXIDE ALARM IS PERMITTED IN EXISTING DWELLING UNITS <br />WHERE NO CONSTRUCTION IS TAKING PLACE. <br />3). THE NFRC TEMPORARY LABEL DISPLAYED ON WINDOWS <br />MUST REMAIN ON THE UNIT UNTIL FINAL INSPECTION. MAX. U- <br />FACTOR: 0.30 MAX. SHGC: 0.23 ENERGY CODE REQUIREMENTS: <br />(TABLE 150.1-A) <br />4). ADU ADDRESSING - BUILDING SHALL HAVE APPROVED <br />ADDRESS NUMBERS (CRC R319.1) IN A POSITION THAT IS <br />PLAINLY VISIBLE FROM THE STREET FRONTING THE PROPERTY. <br />NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. <br />ADDRESS NUMBERS SHALL BE A MINIMUM 4 INCHES HIGH AND <br />1/2 INCH STROKE WIDTH. SHOW ON ELEVATION. A. IF <br />ILLUMINATED; COMPLY WITH CALIFORNIA ENERGY CODE <br />SECTION 140.8; OR B. SIGN SHALL CONSUME NO MORE THAN 5 <br />WATTS OF POWER AS DETERMINED ACCORDING TO SECTION <br />130.0(C) (15) <br />5). VAPOR RETARDER IS REQUIRED OVER (E) GARAGE SLAB AS <br />REQUIRED IN SECTION R506.2.3. PROVIDE REDGARD <br />WATERPROOFING AND CRACK PREVENTION MEMBRANE. <br />APPLICATION PER ICC - ESR#1413. <br />6). THE EXTERIOR LANDING OR FINISHED FLOOR SHALL NOT BE <br />MORE THAN 7 3/4" BELOW THE TOP OF THE THRESHOLD <br />PROVIDED THE DOOR DOES NOT SWING OVER THE LOVER <br />LANDING OR FLOOR. <br />GENERAL NOTES <br />HERS ITEMS LIST <br />(N) WINDOWS AND DOORS SCHEDULE <br />1/2" = 1'-0" <br />(N) A/C DUCTLESS FAN <br />(N) PREFABRICATED <br />SHOWER WITH GRAB BARS <br />SEE AGING-IN PLACE <br />REQUIREMENTS NOTES.EXHAUST FAN (50 CFM) WITH HUMIDITY CONTROL WITH LED <br />LIGHT (HIGH EFFICACY) <br />FAN WITH LED LIGHT (HIGH EFFICACY) <br />EXTERIOR LIGHT W/PHOTO SENSOR CONTROL AND MOTION <br />DETECTOR <br />6" RECESSED LED LIGHT (HIGH EFFICACY) <br />VANITY LED LIGHT (HIGH EFFICACY) <br />CEILING MOUNTED LED LIGHT (HIGH EFFICACY) <br />1. DOORBELL BUTTONS - DOORBELL BUTTONS OR CONTROLS, WHEN <br />INSTALLED, SHALL NOT EXCEED 48 INCHES ABOVE EXTERIOR FLOOR OR <br />LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON <br />ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER <br />FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48 INCHES <br />MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD <br />DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A <br />HEIGHT NOT EXCEEDING 48 INCHES ABOVE EXTERIOR FLOOR OR <br />LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR <br />CONTROL. (CRC R327.1.4) <br />2. AGING-IN-PLACE ELEMENTS - AT LEAST ONE BATHROOM ON THE <br />ENTRY LEVEL (SEE DEFINITION) SHALL BE PROVIDED WITH <br />REINFORCEMENT INSTALLED IN ACCORDANCE WITH CRC R327.1. <br />WHERE THERE IS NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE <br />BATHROOM ON THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL <br />COMPLY WITH CRC R327.1. <br />3. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER <br />CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. <br />REINFORCEMENT SHALL NOT BE LESS THAN 2X8 NOMINAL LUMBER (1-1/2 <br />INCH BY 7-1/4 INCH ACTUAL DIMENSION) OR OTHER CONSTRUCTION <br />MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. <br />REINFORCEMENT SHALL BE LOCATED BETWEEN 32 INCHES AND 39-1/4 <br />INCHES ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. <br />4. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE <br />WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. <br />5. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL <br />FRAMING IS PROVIDED. <br />6. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT <br />SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK <br />WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER <br />GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO <br />MORE THAN 6 INCHES ABOVE THE BATHTUB RIM. <br />EXCEPTIONS: <br />I. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE <br />WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM <br />SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR-MOUNTED, <br />FOLDAWAY, OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS <br />APPROVED BY THE ENFORCING AGENCY. <br />II. REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR <br />PRE-FABRICATED SHOWER ENCLOSURES AND BATHTUB WALL PANELS <br />WITH INTEGRAL FACTORY- INSTALLED GRAB BARS OR WHEN FACTORY- <br />INSTALLED REINFORCEMENT FOR GRAB BARS IS PROVIDED. <br />III. SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF <br />REINFORCEMENT AND/OR GRAB BARS SHALL BE PERMITTED, PROVIDED <br />REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS <br />OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />IV. BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS <br />DO NOT PERMIT THE INSTALLATION OF REINFORCEMENT SHALL BE <br />PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR- <br />MOUNTED GRAB BARS ADJACENT TO THE BATHTUB OR AN ALTERNATE <br />METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />V. REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR <br />BATHTUBS AND WATER CLOSETS INSTALLED ON CONCRETE SLAB <br />FLOORS. <br />DOCUMENTATION FOR GRAB BAR REINFORCEMENT - INFORMATION AND/ <br />OR DRAWINGS IDENTIFYING THE LOCATION OF GRAB BAR <br />REINFORCEMENT SHALL BE PLACED IN THE OPERATION AND <br />MAINTENANCE MANUAL IN ACCORDANCE WITH THE CALIFORNIA GREEN <br />BUILDING STANDARDS CODE, CHAPTER 4, DIVISION 4.4. (CRC R327.1.1.1) <br />AGING-IN PLACE REQUIREMENTS <br />1HR FIRE <br />RATED WALL <br />1HR FIRE <br />RATED WALL <br />1 <br />A8 <br />1 <br />A8 <br />PROJECT NAME: MANUEL & MARIA CASAS <br />MAIN HOUSE ADDRESS: 2617 DEODAR ST., <br />SANTA ANA, CA 92705 <br />ADU ADDRESS: 2617 DEODAR ST. UNIT #2, <br />SANTA ANA, CA 92705 <br />WALL LEGEND <br />(N) 4'W X 3'D CONCRETE LANDING: <br />WITH ELEVATION OF 1-1/2" FROM <br />THE TOP OF THE THRESHOLD TO <br />TOP OF CONCRETE LANDING. SEE <br />NOTE 6 FROM GENERAL NOTES. <br />SHOWER WALLS SHALL BE <br />FINISHED WITH A NON- <br />ABSORBENT SURFACE TO A <br />HEIGHT OF 72 ABOVE THE <br />FLOOR. UTILIZE FIBERMAT <br />REINFORCED CEMENT <br />BACKER BOARD AS A BASE <br />FOR TILE. ENCLOSURE <br />DOORS AND / OR PANELS <br />SHALL BE TEMPERED <br />GLASS. <br />1. ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS <br />(INCLUDING CONTROLS FOR HEATING, VENTILATION AND AIR <br />CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE <br />LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE <br />OUTLET BOX AND NOT LESS THAN 15 INCHES MEASURED FROM THE <br />BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. <br />EXCEPTIONS: <br />I. DEDICATED RECEPTACLE OUTLETS; FLOOR RECEPTACLE OUTLETS; <br />CONTROLS MOUNTED ON CEILING FANS AND CEILING LIGHTS; AND <br />CONTROLS LOCATED ON APPLIANCES. <br />II. RECEPTACLE OUTLETS REQUIRED BY THE CALIFORNIA ELECTRICAL <br />CODE ON A WALL SPACE WHERE THE DISTANCE BETWEEN THE FINISHED <br />FLOOR AND A BUILT-IN FEATURE ABOVE THE FINISH FLOOR, SUCH AS A <br />WINDOW, IS LESS THAN 15 INCHES. <br />2. ADDS AUTO-OFF CONTROLS FOR LIGHTING CONTROLS IN DRAWERS <br />AND CABINETS. <br />3. UNDERSHELF, DISPLAY CABINETS, SWITCHED OUTLETS CONTROLLED <br />SEPARATE FROM THE CEILING LIGHTING. <br />4. LIGHTING IN HABITABLE SPACES SHALL HAVE ACCESSIBLE WALL- <br />MOUNTED DIMMING CONTROLS. <br />ELECTRICAL OUTLET AND SWITCH <br />NOTES:VAPOR RETARDER IS <br />REQUIRED OVER (E) GARAGE <br />SLAB AS REQUIRED IN <br />SECTION R506.2.3. PROVIDE <br />REDGARD WATERPROOFING <br />AND CRACK PREVENTION <br />MEMBRANE, C-CURE PRO-RED <br />WATERPROOFING AND ANTI- <br />FRACTURE MEMBRANE, AND <br />JAMBO WATERPROOFING <br />MEMBRANE APPLICATION PER <br />ICC-ESR#1413
The URL can be used to link to this page
Your browser does not support the video tag.